BRENNEN

Industries / Construction and property / Commercial and residential construction / Fencing

Inspection and repair

Checking fences for rot, rust, wind and fire damage, and fixing or rebuilding what fails.

5

Milestones achieved, from 1984 to 2013.

1

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1984

    Old iron rolled again

    After puddled wrought iron stopped being made (see Materials), blacksmith Chris Topp set up his own rolling mill, and from 1984 his Real Wrought Iron company sold re-rolled wrought iron to blacksmiths for heritage work. Railings and gates could then be repaired in their original metal; his own work includes railings and gates for Middlethorpe Hall in York (1982), by Designing Buildings Wiki's account. Conservation guidance now asks that recycled wrought iron be used to repair quality wrought ironwork, that loose railings be reset in molten lead rather than resin, and that welding be avoided where possible.

    designingbuildings.co.ukbuildingconservation.com

    Credit

    Chris Topp

  2. 1992

    Thirty years of push tests

    In 1960 and 1961 the US Forest Service set 975 ponderosa pine fence posts 2.5 ft deep at two sites in South Dakota, one semiarid and one more humid. Once a year an inspector pushed each post with a 50 lb sideways load, and any post that broke off, or had decayed at the top until it could no longer hold a stapled wire, counted as failed. The 30-year report of 1992 found that every untreated post had failed, with a probable life of 13 years at the dry site and 11 at the humid one, while posts treated with preservatives "performed well".

    LessonThe preservative most posts actually received "differed substantially" from the target, probably because they were treated in mixed loads with other products, so a post's nominal treatment does not prove what it absorbed.

    fs.usda.gov

    Credit

    Donald Markstrom and Lee Gjovik, USDA Forest Service

  3. 2008

    Post spacing set by wind

    The Chain Link Fence Manufacturers Institute (CLFMI), a US trade group, publishes tables that give the widest safe spacing for the line posts of a chain-link fence of a given height, post size and fabric at a given design wind speed; the 2008 edition worked from the ASCE 7-05 wind standard and the 2023 edition from ASCE 7-22. The tables treat the fence as a solid panel and then allow wider spacing for open mesh, by a factor of 6.4 for #9 gauge wire in 1¾ in mesh. In the guide's own example, a 10 ft fence on 4 in steel pipe posts in a park with a 105 mph design wind keeps the usual 10 ft spacing; made solid, the same factors give posts about every 5.2 ft.

    hooverfence.comres.cloudinary.com

    Credit

    CLFMI, with Pagnotta Engineering and Charles Naegele

  4. 2009

    Volunteers rebuild burnt fences

    Kevin and Rhonda Butler lost about 3 km of fencing in the Black Saturday bushfires in Australia. They expected repairs to take three to four months; about 25 volunteers who answered a newspaper advert rebuilt it in a week. The Butlers then founded BlazeAid, which by its own account cleared 500 km of burnt fence and rebuilt another 500 km from its first camp over 11 months, has answered a disaster every year since, and ran 45 camps after the 2019–20 fires.

    blazeaid.com.au

    Credit

    Kevin and Rhonda Butler, BlazeAid

  5. 2013

    A hoarding topples a wall

    On 28 March 2013, in strong wind, a freestanding brick wall on Swanston Street, Melbourne, fell and killed three pedestrians. A timber advertising hoarding 3.2 m high, up to 70 cm taller than the wall, had been fixed to it, and WorkSafe Victoria said the hoarding "increased the risk of the wall collapsing". Grocon (Victoria Street), which controlled the site, and Aussie Signs, which arranged the hoarding, were each convicted and fined A$250,000, and in 2018 the coroner found that the wall's structural safety had been Grocon's responsibility.

    LessonAnything that closes up a boundary wall or fence, such as signs, screens or slats, adds wind load and needs a structural check before it goes up.

    knowledge.aidr.org.authenewdaily.com.au

    Credit

    WorkSafe Victoria; Coroner Sara Hinchey

Watch for

  1. Pulse fences kept in sync

    A monitored pulse fence is an electric security fence that both deters and raises an alarm when it is cut or shorted. Gallagher Security says its new F5 and F6 fence controllers keep pulse timing consistent along a perimeter and adjust energy levels automatically if the synchronization signal is lost, so the fence stays within newly introduced "safe limits", and that they align with IEC 60335-2-76, the safety standard for electric fence energizers.

    Achieved whenan independent test laboratory certifies the controllers to the current edition of IEC 60335-2-76, or a site operator publishes alarm and fault records from a perimeter that uses them.

    securitybrief.co.uk

    Claimed by

    Gallagher Security, March 2026

Open

  1. 01

    Farm fence faults by drone

    An open, labeled set of drone images of farm fences, and a model trained on it, that marks broken or slack wires, leaning or snapped posts, gaps under the bottom wire, and grass or branches touching an electric wire, so a farmer can fly a fence line instead of driving or walking it.

    The brief
    Credit · unclaimed
  2. 02

    Fences counted after storms

    A public count of the fences left standing, leaning or down after a hurricane, sorted by material (wood, vinyl, chain link, metal panel), height and estimated wind speed, made from photos taken after the storm, so owners and fencers can see which kinds of fence hold.

    The brief
    Credit · unclaimed

Open 01 · the brief

Farm fence faults by drone

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open, labeled set of drone images of farm fences, and a model trained on it, that marks broken or slack wires, leaning or snapped posts, gaps under the bottom wire, and grass or branches touching an electric wire, so a farmer can fly a fence line instead of driving or walking it.

Why it is still open

The nearest published work is for airport security fences. Nils Friederich, Andreas Specker and Jürgen Beyerer of Karlsruhe (2023) recorded their own images of fence damage for a ground robot because "there is no publicly available dataset for the task", and published their trained models. On farms, Aerodyne Australia's iLAMS project for Meat & Livestock Australia (2020) trained a model to mark steel, mesh and dog fences in drone images as working or damaged, but reported that its training set, in the order of a hundred labeled images of faulty fences, was too small for the model to learn some fence types and conditions. A search of GitHub found a student project on drone breach detection and smart-city fence-damage image sets from China, but no open labeled set for farm fences.

arxiv.orgmla.com.au

Built with what exists

A small drone with a zoom camera, such as a DJI Mavic 3 Enterprise, flown along the fence on a planned route; CVAT or Label Studio for labeling; Ultralytics YOLO, or the published airport-fence models, as a starting point; a GPS-logged walked inspection as ground truth.

  1. First step

    Walk 2 km of one farm's fence logging every fault, fly the same line that day, and label the first 200 images.

  2. Done looks like

    At least 20 km of fence on at least three farms flown and walked in the same week, at least 2,000 labeled images released openly, and the share of walked-inspection faults the model finds, and its false alarms, published for each fault type.

Open 02 · the brief

Fences counted after storms

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public count of the fences left standing, leaning or down after a hurricane, sorted by material (wood, vinyl, chain link, metal panel), height and estimated wind speed, made from photos taken after the storm, so owners and fencers can see which kinds of fence hold.

Why it is still open

Damage surveys after storms count buildings, not fences. The University of Florida's survey of buildings damaged by Hurricanes Helene and Milton for the Florida Building Commission (David Prevatt, David Roueche and Kurtis Gurley, June 2025) does not mention fences once. Wind design for fences comes from tables such as CLFMI's (see Achieved), not from counts of fences that failed. A search for a published count of storm-damaged fences by type found none.

floridabuilding.org

Built with what exists

The aerial photos that NOAA's National Geodetic Survey flies after major US storms, free on its Emergency Response Imagery site (Milton, Helene, Ian and others); street-level photos from Mapillary taken before and after; the National Hurricane Center's wind swath maps; a general AI model that reads images, such as Claude Fable 5.2 (see the Note "Three working devices"), to flag fences for two people to check; QGIS.

  1. First step

    Download NOAA's post-storm photos for one neighborhood that Hurricane Milton hit, and sort 200 fences by type and condition by hand.

  2. Done looks like

    At least 2,000 fences along one storm's path, each sorted by type and condition by two people who agree on at least 90% of them, with the share down by fence type in each wind band published and locations rounded to the block for privacy.