BRENNEN

Industries / Construction and property / Commercial and residential construction / Fencing

Gates and access control

Hanging gates and making them safe: self-closing hinges and latches, barriers around pools, and powered gates with the sensors and controls that open them.

5

Milestones achieved, from 1998 to 2019.

1

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1998

    Pool fences shown to work

    A Cochrane review, which pools the published studies on one question, found no trials of pool fencing but three case-control studies, which compare children who drowned with children who did not. The odds of a child drowning or nearly drowning were about a quarter as high in a fenced pool as in an unfenced one (odds ratio 0.27), and fencing on all four sides that cuts the pool off from the house did far better than fencing that left the house as the fourth side (odds ratio 0.17). The authors called for laws requiring such isolation fencing, with secure self-latching gates, for new and existing pools, with enforcement.

    cochranelibrary.comcochrane.org

    Credit

    D. C. Thompson and F. Rivara, Cochrane Database of Systematic Reviews (1998)

  2. 2000

    Gate motors must sense people

    UL 325 is the US safety standard for powered door, gate and window operators. Its first edition, in 1973, covered garage doors only. Gate makers in DORCMA, now the Gate Operator Division of the Door and Access Systems Manufacturers Association (DASMA), pushed for gate rules from the early 1990s, and Underwriters Laboratories adopted them in the fall of 1998. From March 2000 a vehicular gate operator had to come with, or accept, a primary and a secondary means of entrapment protection: ways to stop and reverse the gate before it traps a person against a post or wall, such as a photoelectric beam or a pressure-sensitive edge.

    dasma.comdasma.com

    Credit

    DORCMA (now DASMA) members and Underwriters Laboratories

  3. 2010

    Powered gates crush children

    In February 2010 Britain's Health and Safety Executive (HSE) warned gate makers and installers after a nine-year-old reached through a gap between a gate and its brick pillar to press an exit button and was crushed as the gap closed; the motor's obstacle sensors did not stop the gate. In September 2010 HSE reported two more young children killed by automatic sliding gates, trapped at the closing edge because the force was not limited to the values in the European standard BS EN 12453. HSE said force limiting on its own was "unlikely to be sufficiently reliable", and asked for pressure-sensitive edges as well on gates that run automatically in public places, with forces measured before use and rechecked at each service.

    LessonThe light beam on the first gate was set to detect cars, not a child at the hinge, so each gap and edge has to be checked as installed.

    hse.gov.ukhse.gov.uk

    Credit

    HSE Field Operations Directorate

  4. 2016

    Safety sensors must be monitored

    Inspections of US automated gates, and some accidents, showed that in many cases the external entrapment devices had never been installed. From January 2016 UL 325 required gate operators to monitor those devices at least once in every open and close cycle: if a sensor is missing, faulty or cut off, the gate moves only while someone holds a button down. An August 2018 change made clear that two independent means of protection are needed in each direction of each place a person can be trapped.

    LessonInstallers had read the 2000 rule's second device as optional, and UL had to issue a clarifying decision in 2009 before writing monitoring into the standard.

    dasma.com

    Credit

    Underwriters Laboratories, with DASMA; account by Rick Sedivy of DoorKing

  5. 2019

    Every pool on a register

    Between January 2000 and May 2019, 27 young children drowned in home pools or spas in Victoria, Australia, and in 20 of those cases the barrier did not meet safety standards, by the Victorian Auditor-General's count. Regulations in effect from 2019 required owners to register every pool with their council by 1 November 2020 and to have an inspector certify the barrier every four years; a barrier fails if, for example, its gate does not self-close and self-latch.

    LessonA register shows where pools are, not whether their gates work: the five audited councils had received only 45% of the compliance certificates due by 1 June 2022, so they could not say whether 3,535 pools were safe.

    audit.vic.gov.au

    Credit

    Victorian Government; audit by the Victorian Auditor-General's Office (February 2023)

Watch for

  1. Cameras in place of edges

    La Barrière Automatique, a French maker of barrier arms, folding gates and retractable bollards, sells LBAi Detect, an AI camera system it says "eliminates the need for installing sensors and pressure-sensitive bars" and loops buried in the road. One camera watches the safety zone; a second can be set to tell pedestrians, bicycles, cars, trucks and buses apart. This runs against HSE's 2010 advice to add pressure-sensitive edges in public places.

    Achieved whenan independent test laboratory publishes how reliably the system detects people in the gate's danger zone, in rain, fog and darkness, and a standards body accepts it in place of edges or loops.

    directindustry.comgrouplba.com

    Claimed by

    La Barrière Automatique, September 2025 (product listing) and October 2026 (company article)

Open

  1. 01

    Pool gate closings logged

    A small battery logger that clips to a pool gate and records every opening, and whether the gate then swung shut and latched on its own within a set time, such as 10 seconds. Run it on many home pool gates through a summer and publish how often self-closing gates fail between inspections.

    The brief
    Credit · unclaimed
  2. 02

    An open gate force meter

    An open design for the instrument that measures how hard a powered gate pushes when it meets an obstacle, recording the force curve as BS EN 12445 sets out, at a fraction of the price of a commercial meter, so that small installers can measure every gate they fit.

    The brief
    Credit · unclaimed

Open 01 · the brief

Pool gate closings logged

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A small battery logger that clips to a pool gate and records every opening, and whether the gate then swung shut and latched on its own within a set time, such as 10 seconds. Run it on many home pool gates through a summer and publish how often self-closing gates fail between inspections.

Why it is still open

Inspections check a gate on one day every few years, and the Victorian Auditor-General found that audited councils did not know whether 55% of due pools met the standards. Products that warn of an unlatched gate exist, such as D&D Technologies' MagnaLatch ALERT, which beeps and shows an "unlatched" alarm, but they sound an alarm rather than keep a record. A search of the web and GitHub in November 2026 found no field data on how often self-closing pool gates fail to latch.

audit.vic.gov.auimages.thdstatic.com

Built with what exists

An ESP32 microcontroller board; a magnetic reed switch or Hall-effect sensor at the latch; an accelerometer to sense the gate swinging; a lithium battery; Wi-Fi or LoRaWAN radio, or a memory card; a self-closing gate kit with a magnetic latch for bench tests.

  1. First step

    Build one logger, fit it to a self-closing gate, and run 200 staged closings, some held short of the latch, to check it records each one.

  2. Done looks like

    Bench tests in which the logger catches 100 of 100 staged closings that fail to latch, then 30 home pool gates logged for at least 90 days, with the share of openings that did not latch within 10 seconds published for each gate, beside its hinge and latch type and age.

Open 02 · the brief

An open gate force meter

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open design for the instrument that measures how hard a powered gate pushes when it meets an obstacle, recording the force curve as BS EN 12445 sets out, at a fraction of the price of a commercial meter, so that small installers can measure every gate they fit.

Why it is still open

HSE told installers in 2010 that without the right test equipment they cannot be sure a gate meets the standards and should not install it. A commercial closing-force meter such as PCE Instruments' FM100 lists at €1,587 before tax. Searches of the web and GitHub found no open design.

hse.gov.ukpce-instruments.com

Built with what exists

A 2 kN S-type load cell; a fast 24-bit analog-to-digital converter board such as the ADS1256; an ESP32 or Raspberry Pi Pico to log the curve; the spring set the standard specifies; a 3D-printed housing; a borrowed or rented calibrated commercial meter for reference; a small sliding-gate kit and operator on a bench frame, run with nobody in its path.

  1. First step

    Build the load cell and logger and calibrate them with known weights from 5 to 50 kg.

  2. Done looks like

    50 closing runs on the bench rig measured by both the open meter and a calibrated commercial meter, with peak and lasting forces agreeing within 5% or 10 N, whichever is larger; design files, firmware and all test data published.