Industries / Construction and property / Engineering and architecture
Mechanical and electrical design
Mechanical and electrical design is the work of planning the heating, cooling, fresh air, water, power, lighting and fire systems inside buildings and plants; the trade calls it MEP, for mechanical, electrical and plumbing.
7
Milestones achieved, from 1897 to 2016.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1897
A national wiring rulebook
The National Electrical Code, a US rulebook for how electrical wiring is designed and installed, first appeared in 1897. Its publisher, the National Fire Protection Association (NFPA), says all 50 US states now enforce it.
Credit
the National Fire Protection Association, which publishes it as NFPA 70
1902
Controlling indoor humidity
Humid air was causing trouble at the Sackett-Wilhelms Lithographing and Publishing Company in Brooklyn. Willis Carrier, an engineer at the Buffalo Forge Company, designed a system that controlled the humidity with cooling coils, which the US Department of Energy calls the first modern electrical air conditioning unit.
Credit
Willis Carrier, Buffalo Forge Company
1975
Energy limits for new buildings
After the energy crisis of the 1970s, the engineering society ASHRAE published Standard 90-75 for saving energy in new buildings. A federally funded study by Arthur D. Little reported in February 1976 that several US states had already adopted it, and trade press reported in 2010 that 38 states had codes meeting or beating a version of its successor, Standard 90.1.
Credit
ASHRAE
1976
Water systems spread disease
The US Centers for Disease Control (CDC) found the Legionella bacterium after an outbreak among people who had attended an American Legion convention in Philadelphia in 1976. In 2015 ASHRAE published Standard 188, which calls for a written water management program in large or complex buildings, and a 2016 CDC review found maintenance gaps that such a program could have addressed in 23 of 27 outbreaks (85%), with cooling towers the source in 6.
LessonHow a building's water systems are designed and kept can decide whether they spread disease.
Credit
US CDC; ASHRAE
1997
A public energy model
The US Department of Energy (DOE) has developed EnergyPlus since 1997. It is free, open-source software that estimates a whole building's energy use before the building exists, and it succeeded DOE-2, an earlier DOE-funded program written by James J. Hirsch & Associates with Lawrence Berkeley National Laboratory. DOE puts out two updates a year.
Credit
US Department of Energy and its national laboratories
2012
An airport stalled by smoke
Berlin Brandenburg Airport did not open as planned in 2012 because final safety checks found its smoke extraction system, the fans and ducts that clear smoke so people can escape a fire, was defective. In 2017 the inspection body TÜV still had not approved the system and found faults in 49 of 104 sprinkler zones; the aviation authority approved opening in October 2020.
LessonA building cannot open until its fire systems pass their acceptance tests, so a design flaw found late can hold up a whole project for years.
Credit
the Berlin Brandenburg airport company; inspections by TÜV
2016
Buildings use more than predicted
Chris van Dronkelaar and colleagues at University College London and BuroHappold Engineering reviewed published case studies and found that non-domestic buildings used 34% more energy than predicted on average, with a standard deviation of 55%, across 62 buildings. They traced the gap mainly to modeling assumptions, occupant behavior and poor operation.
LessonThe review found that energy predicted at design can be checked only against metered data, and called for that data to be accessible.
Credit
Chris van Dronkelaar, Mark Dowson, Esfand Burman, Catalina Spataru and Dejan Mumovic
Watch for
AI-routed electrical conduit
Augmenta says its software routes electrical raceways, the conduit and cable trays that carry wiring, automatically inside Revit building models, and that Mt. Hope Elementary School in Lansing, Michigan, is the first building constructed with an AI-designed electrical system. It reports 25% faster design, 15% less wasted material and a month less to get ready for prefabrication, all its own figures.
Achieved whenAn independent study, or several unrelated firms, publish measured results from real projects.
Claimed by
Augmenta, October 2025, as reported by AEC Magazine
Open
01
Routing test floors
A public set of test floors for software that lays out ducts, pipes and cable trays automatically, with fixed scoring rules: clashes left, total length, number of bends, slope for drainage and clearance for maintenance. Include a baseline router and its scores.
The briefCredit · unclaimed02
Design rating against the meter
An open table that matches, building by building, the two public energy ratings for buildings in England and Wales: the Energy Performance Certificate (EPC), calculated from the building's design and its heating, cooling and lighting systems, and the Display Energy Certificate (DEC), based on a year of metered energy use. Publish the gap by building type.
The briefCredit · unclaimed
Open 01 · the brief
Routing test floors
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public set of test floors for software that lays out ducts, pipes and cable trays automatically, with fixed scoring rules: clashes left, total length, number of bends, slope for drainage and clearance for maintenance. Include a baseline router and its scores.
Why it is still open
A 2025 review by Youngseo Hwang, Kenneth Park and Sungkon Moon of Ajou University and Aston University found "key limitations in existing MEP auto routing systems." Augmenta's results, listed under Watch for, are its own. The largest public data found for this work is for recognizing pipes in laser scans, not routing them, and the biggest such set, Industrial3D, had not yet released its data.
Built with what exists
The free Common BIM Files from the US Army Corps of Engineers and the National Institute of Building Sciences, three building models (an apartment building, a clinic and an office) with mechanical, electrical and plumbing systems; IfcOpenShell to read them; open path-finding code. AI models already route the copper tracks on circuit boards, a similar task (see the Note "Three working devices").
First step
Remove the ducts from one floor of the Common BIM Files office building and write the scoring rules against the original layout.
Done looks like
Ten test floors with their scoring code published, and a results table for at least two routers, one of them the baseline, that a second person reproduces.
Open 02 · the brief
Design rating against the meter
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
An open table that matches, building by building, the two public energy ratings for buildings in England and Wales: the Energy Performance Certificate (EPC), calculated from the building's design and its heating, cooling and lighting systems, and the Display Energy Certificate (DEC), based on a year of metered energy use. Publish the gap by building type.
Why it is still open
The 2016 review above rested on only 62 buildings and called for accessible energy data. The government's register now offers both certificate types for bulk download under the Open Government Licence, and this research found no published building-by-building match.
frontiersin.orgget-energy-performance-data.communities.gov.uk
Built with what exists
The bulk EPC and DEC files; Python; the Unique Property Reference Number (UPRN), where present, to match buildings; a language model to suggest matches between messy addresses, each checked by a person.
First step
Download the DEC file and the non-domestic EPC file and count how many records share a UPRN.
Done looks like
At least 5,000 matched buildings published with code, a hand check of 100 random matches finding at least 95% correct, and a table of the median gap for each building type.