BRENNEN

Industries / Construction and property / Engineering and architecture

Mechanical and electrical design

Mechanical and electrical design is the work of planning the heating, cooling, fresh air, water, power, lighting and fire systems inside buildings and plants; the trade calls it MEP, for mechanical, electrical and plumbing.

7

Milestones achieved, from 1897 to 2016.

1

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1897

    A national wiring rulebook

    The National Electrical Code, a US rulebook for how electrical wiring is designed and installed, first appeared in 1897. Its publisher, the National Fire Protection Association (NFPA), says all 50 US states now enforce it.

    nfpa.org

    Credit

    the National Fire Protection Association, which publishes it as NFPA 70

  2. 1902

    Controlling indoor humidity

    Humid air was causing trouble at the Sackett-Wilhelms Lithographing and Publishing Company in Brooklyn. Willis Carrier, an engineer at the Buffalo Forge Company, designed a system that controlled the humidity with cooling coils, which the US Department of Energy calls the first modern electrical air conditioning unit.

    energy.gov

    Credit

    Willis Carrier, Buffalo Forge Company

  3. 1975

    Energy limits for new buildings

    After the energy crisis of the 1970s, the engineering society ASHRAE published Standard 90-75 for saving energy in new buildings. A federally funded study by Arthur D. Little reported in February 1976 that several US states had already adopted it, and trade press reported in 2010 that 38 states had codes meeting or beating a version of its successor, Standard 90.1.

    osti.govhpac.com

    Credit

    ASHRAE

  4. 1976

    Water systems spread disease

    The US Centers for Disease Control (CDC) found the Legionella bacterium after an outbreak among people who had attended an American Legion convention in Philadelphia in 1976. In 2015 ASHRAE published Standard 188, which calls for a written water management program in large or complex buildings, and a 2016 CDC review found maintenance gaps that such a program could have addressed in 23 of 27 outbreaks (85%), with cooling towers the source in 6.

    LessonHow a building's water systems are designed and kept can decide whether they spread disease.

    cdc.govcdc.gov

    Credit

    US CDC; ASHRAE

  5. 1997

    A public energy model

    The US Department of Energy (DOE) has developed EnergyPlus since 1997. It is free, open-source software that estimates a whole building's energy use before the building exists, and it succeeded DOE-2, an earlier DOE-funded program written by James J. Hirsch & Associates with Lawrence Berkeley National Laboratory. DOE puts out two updates a year.

    energy.govdoe2.com

    Credit

    US Department of Energy and its national laboratories

  6. 2012

    An airport stalled by smoke

    Berlin Brandenburg Airport did not open as planned in 2012 because final safety checks found its smoke extraction system, the fans and ducts that clear smoke so people can escape a fire, was defective. In 2017 the inspection body TÜV still had not approved the system and found faults in 49 of 104 sprinkler zones; the aviation authority approved opening in October 2020.

    LessonA building cannot open until its fire systems pass their acceptance tests, so a design flaw found late can hold up a whole project for years.

    irishtimes.comthelocal.deberliner-kurier.de

    Credit

    the Berlin Brandenburg airport company; inspections by TÜV

  7. 2016

    Buildings use more than predicted

    Chris van Dronkelaar and colleagues at University College London and BuroHappold Engineering reviewed published case studies and found that non-domestic buildings used 34% more energy than predicted on average, with a standard deviation of 55%, across 62 buildings. They traced the gap mainly to modeling assumptions, occupant behavior and poor operation.

    LessonThe review found that energy predicted at design can be checked only against metered data, and called for that data to be accessible.

    frontiersin.org

    Credit

    Chris van Dronkelaar, Mark Dowson, Esfand Burman, Catalina Spataru and Dejan Mumovic

Watch for

  1. AI-routed electrical conduit

    Augmenta says its software routes electrical raceways, the conduit and cable trays that carry wiring, automatically inside Revit building models, and that Mt. Hope Elementary School in Lansing, Michigan, is the first building constructed with an AI-designed electrical system. It reports 25% faster design, 15% less wasted material and a month less to get ready for prefabrication, all its own figures.

    Achieved whenAn independent study, or several unrelated firms, publish measured results from real projects.

    aecmag.com

    Claimed by

    Augmenta, October 2025, as reported by AEC Magazine

Open

  1. 01

    Routing test floors

    A public set of test floors for software that lays out ducts, pipes and cable trays automatically, with fixed scoring rules: clashes left, total length, number of bends, slope for drainage and clearance for maintenance. Include a baseline router and its scores.

    The brief
    Credit · unclaimed
  2. 02

    Design rating against the meter

    An open table that matches, building by building, the two public energy ratings for buildings in England and Wales: the Energy Performance Certificate (EPC), calculated from the building's design and its heating, cooling and lighting systems, and the Display Energy Certificate (DEC), based on a year of metered energy use. Publish the gap by building type.

    The brief
    Credit · unclaimed

Open 01 · the brief

Routing test floors

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public set of test floors for software that lays out ducts, pipes and cable trays automatically, with fixed scoring rules: clashes left, total length, number of bends, slope for drainage and clearance for maintenance. Include a baseline router and its scores.

Why it is still open

A 2025 review by Youngseo Hwang, Kenneth Park and Sungkon Moon of Ajou University and Aston University found "key limitations in existing MEP auto routing systems." Augmenta's results, listed under Watch for, are its own. The largest public data found for this work is for recognizing pipes in laser scans, not routing them, and the biggest such set, Industrial3D, had not yet released its data.

iaarc.orgpointcloudyc.github.io

Built with what exists

The free Common BIM Files from the US Army Corps of Engineers and the National Institute of Building Sciences, three building models (an apartment building, a clinic and an office) with mechanical, electrical and plumbing systems; IfcOpenShell to read them; open path-finding code. AI models already route the copper tracks on circuit boards, a similar task (see the Note "Three working devices").

  1. First step

    Remove the ducts from one floor of the Common BIM Files office building and write the scoring rules against the original layout.

  2. Done looks like

    Ten test floors with their scoring code published, and a results table for at least two routers, one of them the baseline, that a second person reproduces.

Open 02 · the brief

Design rating against the meter

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open table that matches, building by building, the two public energy ratings for buildings in England and Wales: the Energy Performance Certificate (EPC), calculated from the building's design and its heating, cooling and lighting systems, and the Display Energy Certificate (DEC), based on a year of metered energy use. Publish the gap by building type.

Why it is still open

The 2016 review above rested on only 62 buildings and called for accessible energy data. The government's register now offers both certificate types for bulk download under the Open Government Licence, and this research found no published building-by-building match.

frontiersin.orgget-energy-performance-data.communities.gov.uk

Built with what exists

The bulk EPC and DEC files; Python; the Unique Property Reference Number (UPRN), where present, to match buildings; a language model to suggest matches between messy addresses, each checked by a person.

  1. First step

    Download the DEC file and the non-domestic EPC file and count how many records share a UPRN.

  2. Done looks like

    At least 5,000 matched buildings published with code, a hand check of 100 random matches finding at least 95% correct, and a table of the median gap for each building type.