BRENNEN

Industries / Government, education and community / Government / Emergency services

Fighting building fires

Putting out fires in homes, shops, factories and vehicles once the crews arrive, and getting the people inside out alive.

7

Milestones achieved, from 1824 to 2020.

1

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1824

    A city runs the brigade

    In 1824 Edinburgh formed a fire brigade run by the town itself, a municipal service, with James Braidwood, then 24, as its first master of fire engines. Each company had a captain, a sergeant and 18 firemen, and its stations stood on high ground so the engines could reach fires quickly. The Victorian Web, a scholarly history site, calls it the UK's first municipal fire brigade and says it set the pattern for brigades founded around the world in the Victorian period; the Scottish Fire and Rescue Service, its successor, calls it the world's oldest municipal fire service. Braidwood later helped form the London Fire Engine Establishment, which became the London Fire Brigade.

    victorianweb.orgexpressandstar.com

    Credit

    James Braidwood; the town of Edinburgh

  2. 1853

    Paid crews and steam

    On 1 April 1853 Cincinnati, Ohio, set up what the city calls the first professional, fully paid fire department in the United States. Three months earlier the city had been given a steam-powered pump built at Miles Greenwood's Eagle Ironworks by Abel Shawk, Alexander Bonner Latta and Greenwood. A steam pump needed a few trained operators instead of the crowds of volunteers who worked the handles of hand pumps, and American Heritage magazine records that volunteer companies of the time often brawled at fires; in Cincinnati, a building burned unnoticed during one street fight. Steam pumps were not new: by American Heritage's account, Braithwaite and Ericsson built one in London in 1829.

    LessonNew equipment can change who does the work: a machine that needed trained operators replaced a volunteer system that rules alone had not reformed.

    cincinnati-oh.govamericanheritage.com

    Credit

    Miles Greenwood, Abel Shawk and Alexander Bonner Latta; the City of Cincinnati

  3. 2007

    Nine die in a showroom

    On 18 June 2007 nine career firefighters of the Charleston Fire Department in South Carolina died at the Sofa Super Store, a furniture showroom and warehouse. NIOSH, the US federal agency for workplace safety research, found that the fire spread rapidly after a door to the burning loading dock was opened, that crews became disoriented when thick black smoke filled the showrooms from ceiling to floor, and that burning gases then ignited and raced through the main showroom. Its February 2009 report recommended a single incident commander at a fixed command post, tracking of every crew inside, a rapid intervention team (a crew kept ready only to rescue firefighters), better management of breathing air and better use of thermal cameras. NIST, the US measurement and standards agency, separately recommended that model codes require sprinklers in all new furniture stores.

    LessonCrews inside a large burning building need someone outside who knows where they are and how much air they have left.

    stacks.cdc.govnist.gov

    Credit

    investigations by NIOSH and NIST

  4. 2012

    Tactics tested on burning houses

    Flashover is the moment when everything in a room catches fire at once. In tests by Stephen Kerber of Underwriters Laboratories (UL), published in 2012, living rooms with modern synthetic furniture reached flashover 3 min 20 s to 4 min 45 s after ignition, while rooms with mid-20th-century furniture took 29 min 30 s and 34 min 15 s, and one never reached it. In July 2012 UL, NIST and the New York City Fire Department (FDNY) burned 20 empty townhouses on Governors Island to test how crews ventilate and attack fires. They found that opening doors and windows feeds a fire starved of air and can bring rapid flashover, and that water sprayed into the burning room from outside, through a window or door, improved conditions throughout the house. FDNY Commissioner Salvatore Cassano said the department had "adjusted how we operate".

    LessonTactics set when fires grew slowly must be tested again when the fuel in homes changes.

    link.springer.comphys.orgfsri.org

    Credit

    Stephen Kerber and UL's fire researchers (now UL's Fire Safety Research Institute); Dan Madrzykowski of NIST; FDNY

  5. 2017

    Stay put held too long

    In the early hours of 14 June 2017 a kitchen fire in Grenfell Tower, a block of flats in London, escaped into the cladding on the outside wall and within a few hours engulfed almost the whole building; 71 people who were in the tower that night died. Residents had been told to "stay put", the usual advice in blocks whose walls and floors are built to hold a fire inside one flat. The public inquiry found in October 2019 that the London Fire Brigade's planning for such a fire was "gravely inadequate": its commanders had no training in recognizing the need for an evacuation or organizing one, and there was no evacuation plan for the tower. It found that the decision to evacuate "could and should have been made between 01.30 and 01.50" and would likely have meant fewer deaths; the incident commander withdrew the advice at 02.50, almost two hours after the first 999 call at 00.54.

    LessonAdvice that suits a building as designed has to be dropped as soon as the building stops behaving as designed.

    assets.publishing.service.gov.uk

    Credit

    the Grenfell Tower Inquiry, Phase 1 report

  6. 2019

    A robot inside Notre-Dame

    When the roof of Notre-Dame cathedral in Paris burned in April 2019, the Paris Fire Brigade sent Colossus, a remote-controlled tracked robot with a water cannon, into the cathedral. A brigade spokesman said its job was to "extinguish the fire and lower the temperature inside the nave", and IEEE Spectrum reported that it led the way into the most dangerous areas. Its maker, the French company Shark Robotics, says it can carry up to 1,000 kg and be driven from up to 300 m away. Drones borrowed from two government ministries and flown by a police drone unit showed commanders from above where to aim the hoses, The Verge reported.

    firehouse.comspectrum.ieee.orgtheverge.com

    Credit

    Paris Fire Brigade; Shark Robotics

  7. 2020

    Batteries that reignite

    The US National Transportation Safety Board (NTSB) studied three crashes and one non-crash fire involving electric cars. It found that a damaged high-voltage battery keeps "stranded energy", energy with no path to discharge, which can shock responders and reignite the battery after the flames are out. The batteries in two of the crashes reignited at least six times after crews put out the fires, one of them five days after the crash. In its November 2020 report the NTSB checked the emergency response guides of 36 makers, the documents that tell crews how to make a vehicle safe, against 11 kinds of critical information, found that most lacked vehicle-specific instructions for fighting a battery fire, and recommended that makers follow the ISO 17840 international format.

    LessonA battery fire that looks out may not be out.

    ntsb.gov

    Credit

    National Transportation Safety Board

Watch for

  1. Rescue sheets that list hazards

    Euro NCAP, the European car safety rating program, already requires carmakers to give it a rescue sheet for each model it rates: a quick-reference card for crews, in the ISO 17840 layout, no longer than four pages. Its 2026 protocol adds that each sheet must state which hazards, such as the high-voltage battery, have been made safe, and a technical bulletin, TB030, written with fire service input, on what crews need the sheets to show.

    Achieved whensheets for cars rated under the 2026 protocol are published with the new section filled in, and a fire service or other outside body checks a sample of them against the real vehicles.

    ctif.org

    Claimed by

    Euro NCAP, as reported by CTIF, the international association of fire and rescue services, May 2025

Open

  1. 01

    Score every EV response guide

    A public scorecard that grades the emergency response guide for every electric and plug-in hybrid model on sale in the United States against the NTSB's published yes/no checklist: ISO 17840 layout, steps to disconnect the high-voltage battery, how to stabilize the car, general battery-fire warnings, vehicle-specific instructions on where and how to apply water, submerged vehicles, towing and storage. Re-run it every year so readers can see which makers improve.

    The brief
    Credit · unclaimed
  2. 02

    Code the fatality reports

    A public table of every firefighter death report NIOSH has published, one row per death, with the contributing factors the report names coded into fixed categories, such as disorientation in smoke, running out of air, flashover, collapse, no crew tracking, radio failure or a training fire run outside the rules, and a link to the report.

    The brief
    Credit · unclaimed

Open 01 · the brief

Score every EV response guide

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public scorecard that grades the emergency response guide for every electric and plug-in hybrid model on sale in the United States against the NTSB's published yes/no checklist: ISO 17840 layout, steps to disconnect the high-voltage battery, how to stabilize the car, general battery-fire warnings, vehicle-specific instructions on where and how to apply water, submerged vehicles, towing and storage. Re-run it every year so readers can see which makers improve.

Why it is still open

The NTSB's check of 36 makers' guides dates from 2020. Euro NCAP collects rescue sheets for the cars it rates in Europe, but CTIF's account does not say how their content is checked. In July 2025 the US Fire Administration and the National Highway Traffic Safety Administration published their own response guide for electric-vehicle fires; it notes "limited credible response guidance for emergency responders" and does not grade makers' guides. A search found no later published check of US guides against the NTSB criteria.

ntsb.govctif.orgusfa.fema.gov

Built with what exists

makers' published guides; pdftotext; a language model that answers fixed yes/no questions about each document, such as Gemini Decision 1 (see the Note "A thousand questions, one pass"); two people checking a sample of the answers.

  1. First step

    Find the current guides for the makers in the NTSB's 2020 table, score them by hand on the same criteria, and compare with the 2020 results.

  2. Done looks like

    every electric and plug-in hybrid model of the 2026 model year sold in the US scored on all of the NTSB's criteria, with at least 20% of the scores checked by two people and their agreement rate published, and the scorecard and code released; a second round a year later showing what changed.

Open 02 · the brief

Code the fatality reports

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public table of every firefighter death report NIOSH has published, one row per death, with the contributing factors the report names coded into fixed categories, such as disorientation in smoke, running out of air, flashover, collapse, no crew tracking, radio failure or a training fire run outside the rules, and a link to the report.

Why it is still open

Since 1998 NIOSH has investigated more than 700 line-of-duty deaths, about 40% of all US firefighter deaths, and every report lists contributing factors, but the reports are published one at a time, from 2017 on the program's page and earlier ones in CDC Stacks. NIOSH's own 2020 summary sorted the 1,067 recommendations in its 282 reports from 2006 to 2014 into categories, such as training, standard operating procedures and incident command, and published only the totals, not a table by report. Automated coding has been tried on other fire service records, on near-miss narratives (Lehto, Smith and Taylor, 2013) and on 911 incident descriptions (Furek and colleagues, 2025), but a search, including GitHub, found none for these reports.

cdc.govcdc.govcdc.govstacks.cdc.govstacks.cdc.gov

Built with what exists

the report PDFs; pdftotext; a language model that answers a fixed list of questions about each report, such as Gemini Decision 1 (see the Note "A thousand questions, one pass"); two people coding a random sample by hand.

  1. First step

    Download the reports from 2017 on, write a 15-factor codebook from the recommendations in 20 of them, and code those 20 by hand.

  2. Done looks like

    every NIOSH firefighter fatality report from 1998 to 2026 in one public table with at least 15 coded factors; 10% of reports coded independently by two people, with their agreement and the model's agreement with them published for each factor.