Industries / Construction and property / Elevator and escalator services
Inspection and safety codes
Safety codes set how lifts and escalators must be built, tested and kept, and inspection is the regular check, by a public inspector or a licensed private one, that each machine still meets them.
7
Milestones achieved, from 1921 to 2023.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1921
ASME's first elevator code
The American Society of Mechanical Engineers (ASME) issued a 25-page Safety Code for Elevators covering switches, door locks and speed, later known as A17. Its successor, ASME A17.1/CSA B44, written jointly with the Canadian Standards Association, runs to more than 350 pages, ASME says. In 2007 ASME and CSA added A17.7/CSA B44.7, which ASME calls the first performance-based safety code, meaning one that states the level of safety to reach rather than the parts to use.
Credit
ASME
1998
Britain's six-monthly examinations
The UK's Lifting Operations and Lifting Equipment Regulations (LOLER), in force from 5 December 1998, require employers to have equipment that lifts people thoroughly examined at least every six months, or under an examination scheme, and again after anything that may have harmed its safety.
Credit
UK government, Statutory Instrument 1998 No. 2307
2009
Cars moving with doors open
On 3 June 2006, at City Heights Takeshiba, a public housing block in Minato, Tokyo, a lift rose with its doors open as a high school student was stepping out, and he was crushed between the car floor and the top of the landing doorway and died. The investigation found that a short circuit in the brake coil had worn the brake lining until the brake could no longer hold the car. Japan made its periodic inspection criteria more specific from 1 April 2008 and, from 28 September 2009, required new lifts to carry a device that stops a car moving with its doors open. Existing lifts were not covered; after a similar death in a Kanazawa hotel lift on 31 October 2012, the ministry again urged owners to fit the device and began subsidies.
LessonA rule written for new lifts leaves the existing ones exposed to the same failure.
Credit
MLIT; Japan's Consumer Safety Investigation Commission reported on the accident in 2016
2012
Hong Kong registers lift workers
Hong Kong's Lifts and Escalators Ordinance (Cap. 618), enacted in April 2012, came fully into operation on 17 December 2012, replacing the older Cap. 327. It raised the qualifications for registered engineers, added a register of lift and escalator workers and renewal for contractors, and raised penalties. EMSD says registered engineers must examine lifts at least once a year and escalators at least every six months, and contractors must attend failures of a lift's emergency devices within 4 hours.
Credit
Hong Kong government and EMSD
2016
One EU law for lifts
The EU Lifts Directive 2014/33/EU entered into force on 20 April 2016, replacing Directive 95/16/EC. It covers lifts that carry people at more than 0.15 m/s. A lift built to a harmonized standard cited in the EU's Official Journal, now EN 81-20:2020, is presumed to meet the law's essential requirements, the European Commission says; harmonized standards are written by the committee CEN/TC 10.
Credit
European Commission and CEN
2018
Auditors watch the inspectors
New York City's Department of Buildings (DOB) hires private contractors to inspect many of the city's elevators. Auditors from the New York State Comptroller went along on inspections of 12 elevators in nine buildings and found that violations were missed or overlooked on 11 of them, and a review of inspection data found that 14,828 inspections scheduled for contractors in 2015 and 2016 had not been done. A 2019 follow-up found that DOB had carried out three of the nine recommendations in full and four in part.
LessonA record that an inspection took place says nothing about how well it was done.
Credit
Office of the New York State Comptroller
2023
China adds self-testing years
China's market regulator (SAMR) issued new lift inspection rules (TSG T7001-2023) and lift self-testing rules (TSG T7008-2023), in force from 2 April 2023 with a one-year transition. As Chongqing's regulator sets them out, a lift up to 15 years old gets an official periodic inspection in its 1st, 4th, 7th, 9th, 11th, 13th and 15th years and a self-test, by its user, its maintenance firm or a testing body, in the other years; lifts older than 15 years are inspected every year.
Credit
SAMR
Watch for
ISO lift standard for Europe
CEN published EN ISO 8100-1:2026, the international version of the main lift safety standard, on 17 June 2026. The European Elevator Association and European Lift Association, working from an analysis by CEN/TC 10's working group, say it covers the new health and safety requirements of the EU Machinery Regulation (EU) 2023/1230, which apply to lifts from 20 January 2027 where the Lifts Directive does not cover a risk. Until the Commission cites it in the Official Journal, it gives no presumption of conformity.
Achieved whenthe European Commission cites EN ISO 8100-1:2026 in the Official Journal under the Lifts Directive.
Claimed by
European Elevator Association, European Lift Association and CEN/TC 10, June 2026
Open
01
Lift accident reports, one table
A public table of official investigation reports into lift and escalator deaths and serious injuries from at least five places that publish them, such as Japan's transport ministry, Hong Kong's EMSD and Chinese provincial regulators. Each case is coded for equipment type, the part that failed, whether design, maintenance or use was blamed, and what rule changed afterward.
The briefCredit · unclaimed02
Check the overdue lift list
A check of New York City's public lift records. Take the active elevators whose latest Category 1 filing (the yearly no-load safety test) is from 2024 or earlier, or missing, find how many are truly overdue and how many are record errors, such as removed devices still listed as active, and publish the corrected count and the error rate.
The briefCredit · unclaimed
Open 01 · the brief
Lift accident reports, one table
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public table of official investigation reports into lift and escalator deaths and serious injuries from at least five places that publish them, such as Japan's transport ministry, Hong Kong's EMSD and Chinese provincial regulators. Each case is coded for equipment type, the part that failed, whether design, maintenance or use was blamed, and what rule changed afterward.
Why it is still open
Existing studies stay inside one country or one system. CPWR's 2006 report counted 244 US deaths related to elevators and escalators from 1992 to 2003 using labor and consumer-safety records, and a study of the Guangzhou Metro analyzed 967 escalator passenger accidents. A 2015 paper by González Ruibal and colleagues at thyssenkrupp, TMB Barcelona and LECS gathered escalator accident figures from several sources, found that they did not agree when crosschecked, and noted that no single body gathers such data worldwide; it reports that the European Lift Association's statistical committee has collected accident reports, with causes and severity, from its members in 30 countries since 2008, but a search found no public release of those cases. A search found no table that sets the findings of official investigations from several countries side by side.
Built with what exists
Report PDFs from regulators' websites; PyMuPDF and pdftotext for text; machine translation; an AI model that drafts each coding with the page it came from, such as an agent built with Cursor's agent kit (see the Note "Findings that cite notes"); two human coders.
First step
Collect EMSD's yearly lists of equipment failures and Japan's published lift accident reports, and code the first 20 cases.
Done looks like
At least 100 investigated accidents from five jurisdictions, each coded by two people with their agreement measured by Cohen's kappa, a standard score for how often two coders agree beyond chance, and the table and coding rules published.
Open 02 · the brief
Check the overdue lift list
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A check of New York City's public lift records. Take the active elevators whose latest Category 1 filing (the yearly no-load safety test) is from 2024 or earlier, or missing, find how many are truly overdue and how many are record errors, such as removed devices still listed as active, and publish the corrected count and the error rate.
Why it is still open
In the DOB NOW Elevator Safety Compliance data on 18 November 2026, 2,773 of 81,473 active elevators had no Category 1 report year or one before 2025, by a query of the city's data for this file. DOB itself announced in August 2025 that it would issue violations to owners who had not filed their 2024 test and inspection reports, and the state comptroller's 2018 audit counted inspections not done in 2015 and 2016. But the city comptroller's 2013 follow-up audit found that DOB had set no benchmarks to manage its backlog of overdue elevators, and no published count says how many of the flagged devices are record errors. The Elevator Uptime building page read for this file lists inspection records and complaints, not whether the yearly test is overdue.
Built with what exists
NYC Open Data's API; DOB's public device lookup; Python with pandas; a random sampling plan.
First step
Pull the flagged list from the open data API and draw the random sample.
Done looks like
A random sample of 200 flagged devices, each checked against DOB's own device record, with the share truly overdue and its 95% confidence interval published alongside the corrected citywide count.