BRENNEN

Industries / Energy, water and waste / Electric transmission and distribution

Transmission lines

Transmission is building and running the high-voltage lines, on towers or as buried and undersea cables, that carry power long distances from power plants to cities.

6

Milestones achieved, from 1891 to 2019.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1891

    Three-phase AC goes far

    For an electrical exhibition in Frankfurt, a line carried three-phase alternating current 175 km from Lauffen am Neckar at 15 kV. IEEE gives the power as 300 horsepower and the efficiency as over 75%, calls it the first long-distance, high-voltage transmission of three-phase AC, and says it helped make three-phase AC the world's main way to move power.

    ethw.org

    Credit

    Oskar von Miller; Michael Dolivo-Dobrowolsky (AEG); Charles E. L. Brown (Maschinenfabrik Oerlikon)

  2. 1952

    Sweden's 400 kV line

    Vattenfall connected a line of about 1,000 km from the Harsprånget hydro plant in northern Sweden to Hallsberg, designed for 380 kV and run at 400 kV. Vattenfall, the line's owner, calls it the world's first 400 kV line and says it chose AC because demand grew faster than forecast, leaving no time to develop direct current.

    history.vattenfall.comhistory.vattenfall.com

    Credit

    Vattenfall

  3. 1954

    Direct current under the sea

    The Gotland link carried 20 MW at 100 kV through a 96 km undersea cable to the Swedish island of Gotland. IEEE calls it the world's first commercial HVDC (high-voltage direct current) link. Its key part was the mercury-arc valve, which converts AC to DC and back, and IEEE says the link became the testbed for later links such as the one under the English Channel.

    ethw.org

    Credit

    an ASEA and Vattenfall team led by Uno Lamm

  4. 1965

    Hydro-Québec's 735 kV line

    On 29 November 1965 Hydro-Québec opened the first 735 kV line, part of about 600 km of line from the Manicouagan-Outardes dams to Montreal. IEEE says it was the first system in the world designed, built and run at an AC voltage above 700 kV.

    ethw.org

    Credit

    Hydro-Québec; engineer Jean-Jacques Archambault

  5. 1972

    Solid-state switches for HVDC

    A converter station turns AC into DC, or back again, at each end of a DC line. The 320 MW Eel River station in New Brunswick, Canada, used thyristors (solid-state switches) instead of mercury-arc valves, and IEEE calls it the world's first commercial solid-state HVDC converter station.

    ethw.org

    Credit

    Canadian General Electric and NB Power

  6. 2019

    A 1,100 kV DC line

    State Grid Corporation of China put into service a ±1,100 kV DC line about 3,300 km long, from Xinjiang in the west to Anhui in the east, which State Grid says can carry up to 12 GW. (± means one conductor at plus 1,100 kV and one at minus 1,100 kV.) IEEE Spectrum reported that it set world records for voltage, distance and power.

    spectrum.ieee.org

    Credit

    State Grid Corporation of China

Watch for

  1. Flexible DC at 800 kV

    State Grid is building a ±800 kV line about 2,370 km long from Gansu to Zhejiang, with voltage-source converters, a newer kind of converter, at both ends. Hitachi Energy, a supplier, calls it the world's first ultra-high-voltage flexible DC line. The 8,000 MW receiving station's AC side joined Zhejiang's grid on 27 May 2026, and China Daily gives April 2027 for full operation.

    Achieved whenthe whole line runs at rated power and someone outside the builders reports it.

    hitachienergy.comsubsites.chinadaily.com.cn

    Claimed by

    Hitachi Energy, June 2025; status reported by China Daily, May 2026

  2. Superconducting cable for Munich

    A superconducting cable is chilled until its conductor has almost no electrical resistance, so a slim cable can carry a large amount of power. The SuperLink team ran a 150 m demonstration cable rated 110 kV and 500 MVA for six months in Munich and reports low losses and little heat leaking into the cooled pipe.

    Achieved whena full-length cable carries city load in regular service and an outside party reports how it performs.

    publikationen.bibliothek.kit.edu

    Claimed by

    the SuperLink team (D. Willén and co-authors), IEEE Transactions on Applied Superconductivity, April 2026

Open

  1. 01

    An open cable failure record

    A public table of failures on high-voltage underground and undersea cables, one row per event, with the date, the cable, the cause where one was reported, the days out of service, and links to the notices and reports it came from.

    The brief
    Credit · unclaimed
  2. 02

    A public US line map

    An open map of US high-voltage transmission lines that stays current: the last federal public map, checked line by line against OpenStreetMap, with lines built since mid-2025 added and each change linked to its source.

    The brief
    Credit · unclaimed

Open 01 · the brief

An open cable failure record

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public table of failures on high-voltage underground and undersea cables, one row per event, with the date, the cable, the cause where one was reported, the days out of service, and links to the notices and reports it came from.

Why it is still open

CIGRE, the international council of grid engineers, runs the main survey of cable failures under confidentiality rules, never names cable owners, and publishes only aggregate rates. A 31-company research project led by DNV, Deltares and TNO analyzed 135 undersea cable failures, and its conference paper reports them as percentages, not as a list of events.

cigre.orgjicable.org

Built with what exists

Outage notices that EU grid operators must publish within an hour, with the reason, when an outage cuts cross-border capacity by 100 MW or more, or an offshore grid outage cuts wind output by 100 MW or more; operators' press releases and regulators' reports; a language model that drafts each row and cites the sentence it came from (see the Note "Findings that cite notes"); two human checkers.

eur-lex.europa.eu

  1. First step

    List Europe's HVDC interconnectors and collect one year of their forced-outage notices.

  2. Done looks like

    Every forced outage longer than seven days on a European HVDC interconnector since 2015, each with a cause or "not reported," a repair time and a source link, with a second checker agreeing on at least 90% of cause codes, published under an open license.

Open 02 · the brief

A public US line map

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open map of US high-voltage transmission lines that stays current: the last federal public map, checked line by line against OpenStreetMap, with lines built since mid-2025 added and each change linked to its source.

Why it is still open

The US Department of Homeland Security stopped updating its public HIFLD Open portal, which included a map of transmission lines, on 26 June 2025 and discontinued it on 26 August 2025; much of its data moved to a site open only to vetted partners. Volunteers saved the lines layer, covering lines from 69 kV to 765 kV, as a copy made on the day the portal closed.

projectgeospatial.squarespace.comportal.datarescueproject.org

Built with what exists

The archived layer; OpenStreetMap's power line data; GeoPandas for matching shapes; grid operators' and utilities' public project lists for new lines; satellite images for spot checks.

  1. First step

    Download the archived layer and match its 500 kV lines in one state against OpenStreetMap.

  2. Done looks like

    Every archived line at 345 kV and above matched to an OpenStreetMap line or flagged as missing, with the match rate published, and every 345 kV or larger line energized since June 2025 added with a source link, updated monthly for six months.