Industries / Construction and property / Heavy civil / Asphalt production
Emissions
Emissions work measures and limits what a mixing plant puts into the air: dust and burner gases from the drum, vapour and fumes from hot binder, and the carbon dioxide from drying and heating stone.
5
Milestones achieved, from 1974 to 2024.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1974
A federal limit on dust
From 8 March 1974, US rules for new hot mix asphalt plants, those whose construction or modification began after 11 June 1973, limited their stack gases to 90 mg of particulate matter per dry standard cubic metre (0.04 grains per dry standard cubic foot) and to less than 20% opacity, a measure of how much light the plume blocks. The rule covers dryers, the screening, storing and weighing of hot stone, mixers and the dust collectors themselves.
Credit
US Environmental Protection Agency (EPA), New Source Performance Standards, 40 CFR Part 60, Subpart I
1976
Bags fitted to drum plants
A baghouse is a bank of fabric filter bags that catches dust from the exhaust. Early drum plants could not use one, because hydrocarbon smoke from asphalt flashing in the hot drum "will rapidly and permanently clog" the bags, so they relied on wet scrubbers that needed a large supply of water, sometimes trucked in. James D. Brock and Erbie G. Mize of Astec Industries filed in 1976 for a drum plant that injected the asphalt farther from the burner, behind a shield against its radiant heat, so that it did not smoke; the patent was granted in 1980. Fabric filters became the usual collector: EPA's factors put a drum dryer's dust at 28 lb per ton of mix uncontrolled and 0.014 lb per ton behind a fabric filter, and EPA notes that electrostatic precipitators "have met with little success" at asphalt plants.
Lessonthe dust could not be filtered until the smoke that fouled the filters was stopped where it formed.
Credit
James D. Brock and Erbie G. Mize, Astec Industries
2000
Load-out fumes get numbers
When hot mix drops into storage silos and trucks it gives off organic vapour and a fine aerosol of condensed oil, which EPA notes contain small amounts of hazardous air pollutants. In December 2000 EPA added emission factors for silo filling, truck load-out and the first eight minutes after loading to AP-42, its handbook for estimating air emissions, as equations that rise with mix temperature and with the binder's volatility. In March 2004 it added factors for the hot-oil heaters that keep binder warm.
Credit
US EPA
2020
Asphalt vapour forms fine particles
Peeyush Khare, Drew Gentner and colleagues heated road and roofing asphalts in the laboratory at the temperatures of storage (80 to 140 °C), paving and summer roads, and found emissions at 140 °C about ten times those at 60 °C. The vapours form secondary organic aerosol, fine particles made in the air from gases. For the Los Angeles basin the team estimated asphalt-related sources at 1,000 to 2,500 tonnes a year of potential aerosol, more than either gasoline or diesel vehicles, although such emissions were "essentially absent from inventories". In 2023 Mackenzie Humes, Neil Donahue and colleagues reheated real asphalt to about 130 °C in a smog chamber and found that both primary aerosol (emitted as particles) and secondary aerosol form.
Lessona material treated as inert once made was a large source missing from air quality inventories.
Credit
Peeyush Khare and Drew Gentner; Mackenzie Humes and Neil Donahue
2024
Carbon counted per ton
A 2024 reference by Joseph Shacat, Richard Willis and Ben Ciavola for the National Asphalt Pavement Association (NAPA) puts a typical US mix made with natural gas at 53.7 kg of carbon dioxide equivalent (CO2e) per ton from raw materials to plant gate: 57% from raw materials, mostly the binder, 5% from hauling them, and 38% (20.5 kg) from running the plant, where burner fuel is the largest source. By its figures, a plant burning natural gas emits 26% less at the plant stage than one burning diesel. Plants report such figures in Environmental Product Declarations (EPDs), verified reports made in the US with NAPA's Emerald Eco-Label tool, which "Buy Clean" policies of several federal, state and local agencies require paving contractors to submit.
Credit
Joseph Shacat, Richard Willis and Ben Ciavola, NAPA
Watch for
Hydrogen in the burner
Heidelberg Materials UK says its Criggion plant in mid-Wales made the UK's first 20 tonnes of asphalt with 100% hydrogen as burner fuel in July 2025, using a three-fuel burner developed and supplied by Vulcan Asphalt Group. The trade site The Construction Index reported in March 2026 that the trial, part-funded by the UK Department for Energy Security and Net Zero, made 1,303 tonnes of asphalt with 4,522 kg of hydrogen, cut direct (scope 1) emissions by 76% and cut the asphalt's overall carbon footprint by 23%; the company's own page gives no figures.
Achieved whenan independent party publishes measured stack emissions, nitrogen oxides included, and test results for the mix, or the plant runs on hydrogen in routine production.
Claimed by
Heidelberg Materials UK, July 2025 and March 2026
Open
01
Test the fume-temperature curve
A laboratory test of how organic emissions from hot mix change with temperature, run on the same mixes from warm mix to hot mix temperatures (about 120 to 165 °C), and compared with the curve EPA uses to estimate load-out emissions.
The briefCredit · unclaimed02
Tank vapour, measured again
Measurements of the vapour above heated paving binders, with and without common additives, at storage temperatures, compared with the default values EPA gives for estimating emissions from asphalt tanks.
The briefCredit · unclaimed
Open 01 · the brief
Test the fume-temperature curve
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A laboratory test of how organic emissions from hot mix change with temperature, run on the same mixes from warm mix to hot mix temperatures (about 120 to 165 °C), and compared with the curve EPA uses to estimate load-out emissions.
Why it is still open
EPA's load-out equations, rated C on its A-to-E quality scale, multiply emissions by e^(0.0251 × T), with T in °F. By the equation's own terms that is about 2.5 times more emission for each 20 °C (36 °F) rise, so a warm mix made 28 °C (50 °F) cooler should give off about 70% less; that arithmetic is this file's, not EPA's. Khare and colleagues measured a rise of about 70% per 20 °C for heated binder alone between 60 and 140 °C, levelling off at higher temperatures. No source found for this file sets the two side by side or tests the curve on finished mix.
Built with what exists
A university asphalt lab's mixer and ovens; a sealed, heated chamber read by a flame ionization detector (FID), the total hydrocarbon analyser EPA Method 25A uses; mixes made with and without a warm-mix additive; binder volatility measured by the rolling thin film oven test (ASTM D2872), the input AP-42's equations use.
First step
Make one mix in a university asphalt lab and measure its emissions at 135 °C and 155 °C in a sealed chamber.
Done looks like
Total organic emissions measured at five temperatures from 120 to 165 °C for at least six mixes, three runs each, published with a fitted temperature coefficient and its uncertainty beside AP-42's 0.0251 per °F.
Open 02 · the brief
Tank vapour, measured again
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
Measurements of the vapour above heated paving binders, with and without common additives, at storage temperatures, compared with the default values EPA gives for estimating emissions from asphalt tanks.
Why it is still open
AP-42 gives one pair of default constants for "an average liquid asphalt binder" and assigns estimates made with them its lowest rating, E. Inside Climate News reported in 2021 that the formula used to estimate emissions from heated asphalt and heavy fuel oil tanks "leads to underestimates of vapor pressure", that EPA had known of problems with it since at least 2007, and that additives, up to 20% of stored product, have raised vapour pressure inside tanks. Texas's Air Quality Research Program paid the University of Texas at Austin in 2016 and 2017 to compare ways of measuring the vapour pressure of heavy refinery liquids; its scope of work names liquid asphalt, says its vapour pressure was "not known with any certainty", and planned tests on at least three asphalt stocks. Its final report could not be opened for this file, and this research found no public set of measurements on paving binders with additives.
Built with what exists
Litre samples of binder bought from suppliers; sealed headspace vials heated in a laboratory oven; gas chromatography with an FID or a mass spectrometer (GC-MS); EPA's tank-emission method in AP-42 Section 7.1 for comparison.
First step
Buy three binders from local suppliers and run headspace tests on them at 150 °C in a university lab.
Done looks like
Vapour concentrations above the binder at four temperatures from 120 to 180 °C for at least 20 binders from at least five refineries, ten of them with additives, published with fitted vapour-pressure curves beside AP-42's defaults.