Industries / Industrial equipment and services / Industrial services / Thermography
Process equipment
Process thermography reads the outside of furnaces, pipes, tanks and vessels in working plants to find overheating tubes, wet insulation, the level of what is inside and readings that cannot be trusted.
4
Milestones achieved, from 1970s to 2016.
2
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1970s
Cameras look inside furnaces
A fired heater is a furnace whose burners heat oil or gas flowing through steel tubes; a tube that runs too hot slowly stretches and can burst. Grant Jacobson of Becht, a refinery engineering firm, writes that high-temperature thermography was pioneered in the 1970s and 1980s to measure tube temperatures inside furnaces in operation, prompted by tube failures. Cameras for this work look through the flames with a filter that passes only infrared light near 3.9 micrometers (µm), a wavelength at which the hot furnace gases give off little, as FLIR, a camera maker, explains. The images also tell two problems apart: scale, an oxide crust on the outside of a tube, shows sharp-edged patches that look hot but are not overheating, while coke built up inside a tube shows a soft-edged glow that marks real overheating.
LessonJacobson writes that correcting the readings for scale, flames and reflections is hard, and that inaccurate use "erodes the technology's overall credibility".
Credit
refinery inspectors and camera makers, as described by Becht and FLIR; no single developer is named in the sources read
1996
Cameras screen wet insulation
Corrosion under insulation (CUI) is rust that forms out of sight where water is trapped between a pipe or vessel and its insulation. In Inspectioneering Journal in November 1996, Michael Twomey listed infrared among the ways to find it: in the right conditions wet insulation shows a temperature difference from dry insulation, and corrosion is a distinct possibility beneath it. The method is still in use: a guide from the Australasian Corrosion Association (ACA) lists thermography among the CUI inspection methods and says it finds water in the insulation and shows where to aim other methods.
LessonThe ACA notes that thermography does not generally detect the corrosion itself; wet insulation only signals that corrosion may be there.
Credit
Michael Twomey, Inspectioneering Journal; the ACA
2006
Levels read through walls
A thermal camera can show how full a tank is without opening it. Outdoors, the liquid in a tank changes temperature more slowly than the gas above it, so in the hours after sunset the wall shows a line at the liquid surface; images can also show sludge on the bottom and layers of wax, foam or paraffin, as a 2006 guide in Water Technology magazine describes. John Snell and Matt Schwoegler presented the method for tanks and silos at SPIE's Thermosense conference in April 2004.
LessonA tank that is completely full, completely empty or clad in a shiny skin shows an even image with no line, and the guide warns that no one should add product until the level has been confirmed.
Credit
thermographers, among them John Snell and Matt Schwoegler
2016
Hot walls skew tube readings
In a steam methane reformer, which makes hydrogen in catalyst-filled tubes inside a furnace, the tubes are usually the coldest objects in the box, and the walls, floor and ceiling can be 400 to 500 °F (about 220 to 280 °C) hotter. Majd Daher and Oliver J. Smith IV of Air Products, an industrial gas company, showed in Hydrocarbon Processing in June 2016 that radiation from those hotter surfaces, reflected off the tubes, makes a pyrometer (a spot infrared thermometer) read high, with corrections in their examples as large as 50 °F (28 °C) that varied with the tube's position, the view port and the height. Two surface thermocouples mounted on one tube agreed better with the corrected readings than with the raw ones. In 2024 training slides, Johnson Matthey, a catalyst maker that surveys reformers, showed a plant whose own pyrometer readings were "largely incorrect", with about 40 °C of real headroom once corrected, and a chart on which running 20 °C (36 °F) above the design temperature cuts expected tube life by about half.
LessonAn uncorrected reading costs either way: read high, it holds a plant below its real limit; read low, the tubes wear out early.
Credit
Majd Daher and Oliver J. Smith IV, Air Products, using a reflection model by P. Saunders and D. R. White (1996); Olawunmi Odunola, Johnson Matthey
Watch for
Fixed cameras on waste boilers
AMETEK Land, which makes fixed thermal cameras, says in an application note released on 10 April 2026 that fixed thermal imaging in energy-from-waste plants, which burn municipal and hazardous waste to make electricity and heat, can find developing problems such as localized cooling linked to boiler tube leaks early, and so reduce unplanned outages.
Achieved whenan energy-from-waste operator or its insurer reports tube leaks that fixed cameras found, and how much earlier than the plant's other leak checks.
Claimed by
AMETEK Land, April 2026
AI watch on furnace shells
DGC Africa, a refractory and furnace services firm, says it is rolling out Vision AI, a platform that turns cameras into round-the-clock thermal watch over furnace shells, kilns and boilers for mining and metals producers, and that it has supported energy cost reductions by finding abnormal hot zones earlier. It names no site and gives no figures.
Achieved whena named plant publishes faults found or energy saved before and after the system went in, checked by the plant or an outside engineer.
Claimed by
Justin Nothnagel, DGC Africa's commercial director, in Mining Weekly, May 2026
Open
01
Wet pipe insulation, weighed
A public answer key for finding wet pipe insulation by camera. Lengths of insulated pipe carrying warm water (at most 60 °C) and chilled water are set up outdoors with the insulation and metal cladding used on plant pipework. Water is injected into the insulation in weighed amounts at recorded points, cameras image the pipes through day and night, and at the end each section is cut open and weighed, so every image is labeled with how much water lies where. A scoring script lets anyone test a person or a model that marks wet areas.
The briefCredit · unclaimed02
Open code for tube readings
An open-source program that corrects infrared tube readings for the tube's emissivity (how well its surface gives off heat) and for radiation reflected from hotter walls, checked two ways: against the solved examples Air Products published in 2016, and on a bench where a water-cooled steel tube with thermocouples sits inside a ring of electric radiant panels held below 250 °C, so that reflection errors arise as they do in a furnace without a flame or a working plant.
The briefCredit · unclaimed
Open 01 · the brief
Wet pipe insulation, weighed
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public answer key for finding wet pipe insulation by camera. Lengths of insulated pipe carrying warm water (at most 60 °C) and chilled water are set up outdoors with the insulation and metal cladding used on plant pipework. Water is injected into the insulation in weighed amounts at recorded points, cameras image the pipes through day and night, and at the end each section is cut open and weighed, so every image is labeled with how much water lies where. A scoring script lets anyone test a person or a model that marks wet areas.
Why it is still open
Thermography finds water, not rust, and the published tests of how well it does so rest on private data or a single specimen. G. Cadelano and colleagues at Italy's National Research Council (CNR-ITC), with Tecnomare, injected 5 to 30 ml of water into the insulation of one 58 cm length of oil pipe in the laboratory and found it with heated-and-cooled image sequences (Journal of Nondestructive Evaluation, 2016); no images were released with it. Saudi Aramco engineers reported in 2021 that their machine-learning classifier predicted CUI anomalies with 85% to 90% accuracy, projected from 185 field assets, by their own test; Université Laval researchers reported in 2024 a passive method that separates trapped moisture from other thermal effects, with what they call promising performance. No image set from either was found. GitHub and Hugging Face searches in November 2026 found no labeled CUI thermal image set, only a capture program for a FLIR A70 camera written for a CUI project.
api.openalex.orgapi.openalex.orgcorrosion.com.augithub.comiris.cnr.it
Built with what exists
Steel or copper pipe in 3 m lengths; mineral wool, calcium silicate and foam pipe sections with aluminum or stainless cladding from an insulation supplier; a domestic water heater or a sous-vide circulator for the warm line and an aquarium chiller for the cold line; a syringe and a kitchen scale; a radiometric camera such as a FLIR E-series, or a FLIR Lepton module on a Raspberry Pi for time-lapse; a small weather station; Python and OpenCV.
First step
Insulate one 3 m warm-water pipe with mineral wool and cladding, inject 200 g of water at one marked point, and image it every 30 minutes for 48 hours.
Done looks like
At least 40 wet patches across three insulation types, imaged on at least 20 days and nights, about 10,000 images labeled by weighed water content and released under an open license; and for each insulation type and line temperature, the smallest amount of water found 80% of the time, published.
Open 02 · the brief
Open code for tube readings
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
An open-source program that corrects infrared tube readings for the tube's emissivity (how well its surface gives off heat) and for radiation reflected from hotter walls, checked two ways: against the solved examples Air Products published in 2016, and on a bench where a water-cooled steel tube with thermocouples sits inside a ring of electric radiant panels held below 250 °C, so that reflection errors arise as they do in a furnace without a flame or a working plant.
Why it is still open
The correction methods are published as worked examples in a trade journal (Air Products) and as a supplier's own "correction algorithm" in training slides (Johnson Matthey), and Becht writes that the complexity of correction has led to inaccurate use across the industry. Iñigo Martinez and colleagues (Measurement, 2022) set out an error budget and a deep-learning correction model for radiation thermometry in one petrochemical furnace; no code or bench data were found with it. GitHub searches in November 2026 for tube wall temperature correction, reformer tube temperature and pyrometer reflection correction returned no code, and no public bench data with thermocouple references were found.
prd-in.airproducts.commatthey.cominspectioneering.comarxiv.org
Built with what exists
Python with NumPy and the view-factor formulas in heat-transfer textbooks; steel tube with oxidized and clean sections; type K thermocouples and a data logger; ceramic infrared panel heaters on a steel frame; a recirculating water bath; a thermal camera and a spot pyrometer; high-emissivity tape as a reference.
First step
Code the single-reflection correction for one tube and one view port, and check it against the first worked example in the Air Products paper.
Done looks like
The code reproduces every solved example in the Air Products paper; on the bench, at least 50 readings over three surface finishes and two panel temperatures, with raw and corrected errors against the thermocouples published beside all data and the code under an open license.