BRENNEN

Industries / Industrial equipment and services / Industrial services

Thermography

Thermography is the trade of pointing heat cameras at electrical gear, machines, buildings and plant equipment to find the faults that show up as heat, such as a loose connection, a dry bearing, a gap in insulation or a leaking pipe, before they fail or waste energy.

1965

AGA, a Swedish company, built its model 650 heat camera, which a history by FLIR, AGA's successor, calls "the first camera for predictive maintenance", adding "An industry was born." Electric utilities, among the first users, mounted it on vans to check substations.

irinfo.org

33

Milestones achieved across 6 domains.

9

To watch for: announced, not yet confirmed outside.

12

Open deliverables. Nobody has shipped them.

In one minute

Where it started

In 1800 William Herschel, measuring the temperature of the colors in sunlight, found it highest just beyond the red, in light the eye cannot see, now called infrared. Heat cameras were military equipment until 1965, when AGA of Sweden built one for checking equipment and electric utilities took it into their substations. Swedish building researchers published a manual for finding insulation faults with such cameras in 1972, and in 1988 the US Navy wrote rules for surveying ships' electrical gear.

Where it stands

Cameras that once needed liquid nitrogen now run on uncooled sensors declassified in 1992, and since 2014 one has clipped onto a phone for about $350. Standards set how machines, buildings and solar farms are surveyed and how thermographers are certified, insurers run survey programs for their clients, and a drone surveys a solar farm in about a third to half the time a person with a hand-held camera takes. The weak point is the reading, not the camera: wind, light load, shiny surfaces and the person behind the camera all change what is found, and in a 1983 US government test, contractors found under half of the defective wall area on average.

What is open

Most open jobs here are answer keys: test walls with voids of known size, pipe insulation wetted by weighed amounts, bolted joints run at set currents in measured wind, and district heating flyover calls matched to what the operator later dug up, so that people, software and AI models can be scored against the truth. Others are measurements nobody has published: how infrared windows in switchgear age, the emissivity of common plant surfaces, how far programs disagree when they read the same file, and how many hours of warning heat gives compared with vibration.

Domains

AchievedWatch forOpen

Open in thermography

3 of 12 open deliverables

Open · Electrical surveys

Age IR windows in public

A year-long bench test of the IR windows sold for switchgear, with no electrical equipment involved. Buy several windows of each optic material on sale, such as plain and coated calcium fluoride and polymer, keep sets in sealed boxes at fixed humidity, and once a month measure how much infrared each passes by imaging a steady hot target through it and without it. Publish every window's transmission over time and the temperature error a thermographer would make by keeping the value set when the window was new.

Built with what exists

IR windows bought from makers such as IRISS and Flir; sealed plastic boxes held at fixed humidity over saturated salt solutions, a standard laboratory method, with a humidity logger in each; a temperature-controlled hot plate painted with high-emissivity paint, or a blackbody calibrator, as the target; a radiometric thermal camera (one that records a temperature for every pixel); Python for the analysis.

Credit · unclaimed

Open · Mechanical surveys

Time heat against vibration

A public measurement of how many hours of warning heat gives compared with vibration as a bearing wears out. Step one uses public run-to-failure records that log both: for each run, apply fixed alarm rules (for example, vibration three standard deviations above its first hour, and temperature 10 °C above its first hour) and record how long before failure each one fires. Step two runs new bearings to failure on a guarded rig with a thermal camera filming the housing, to add images to the record.

Built with what exists

The BearingDatasets Python library, which loads PRONOSTIA and other sets in one format, plus the KAIST and Paderborn files; Python with pandas; for new runs, a guarded test rig with a radial load on deep-groove ball bearings, an accelerometer, a thermocouple and a radiometric thermal camera such as a FLIR Lepton 3.5 module; Hugging Face to host the recordings.

Credit · unclaimed

Open · Buildings

Insulation grades, checked by camera

A set of wood-frame test walls with insulation voids of measured size, from none to 5% of the wall area, each forming one face of an insulated box kept warm inside while the other side is cold. Certified thermographers, and any AI tool that claims to grade insulation, grade each wall blind against RESNET's three grades, and their calls are scored against the voids actually built in.

Built with what exists

Stud wall panels about 1.2 by 2.4 m (4 by 8 ft) lined with plasterboard, filled with fiberglass batts and blown cellulose, with voids cut to measured areas; an insulated box with a small electric heater and a thermostat; a cold side outdoors in winter or a walk-in cooler; a FLIR E-series camera and a phone-attached camera for comparison; thermocouples; Python with OpenCV to measure the marked areas.

Credit · unclaimed

Where it sits