Industries / Construction and property / Real estate
Running a building
Running a building means operating it day to day: its heating, cooling and ventilation controls, its lifts, its energy use and reporting, and its safety records.
7
Milestones achieved, from 1883 to 2024.
2
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1883
Room temperature by wire
Warren S. Johnson patented an "electric tele-thermoscope", a device in a room that signaled by electric wire when the room reached a set high or low temperature, so heating could be controlled from a distance. In 1885 he and William Plankinton formed the company that became Johnson Controls.
Credit
Warren S. Johnson
1995
A common language for controls
BACnet is a published communication standard that lets heating, cooling, lighting and other control equipment from different makers exchange data. ASHRAE, the US heating and air-conditioning engineers' society, published it as Standard 135 in 1995, and it became an international (ISO) standard in 2003.
Credit
ASHRAE's BACnet committee, whose work began in June 1987
1998
Regular lift examinations
UK regulations require lifting equipment used at work, including lifts that carry people, to be thoroughly examined by a competent person at least every six months, or to a written examination scheme.
Credit
UK government (Lifting Operations and Lifting Equipment Regulations 1998)
2002
Energy certificates across Europe
An EU directive required an energy performance certificate, a rating of how efficiently a building uses energy, to be available when a building is built, sold or rented, and large public buildings had to display theirs. Member states had until January 2006 to bring it into law, and a 2010 directive later replaced it.
Credit
European Parliament and Council (Directive 2002/91/EC)
2009
Owners must report energy
New York City's Local Law 84 requires owners of large buildings to measure and report their energy and water use every year, using the US Environmental Protection Agency's free ENERGY STAR Portfolio Manager tool. The EPA says nearly 25% of US commercial floor space now reports through that tool.
Credit
New York City Council; US Environmental Protection Agency
2022
Grenfell and the golden thread
On 14 June 2017 fire spread through Grenfell Tower, a London apartment block, and 72 people died. The Building Safety Act 2022 followed. It requires the person accountable for a residential building at least 18 m or seven stories tall to keep its safety information digital, current and available, a record the government's guidance calls the "golden thread".
LessonIf nobody keeps a full, current record of how a building was built and changed, the people running it cannot manage its fire risk.
Credit
UK Parliament; Grenfell Tower Inquiry
2024
Emissions caps on buildings
New York City's Local Law 97, passed in 2019, set greenhouse-gas limits for most buildings over 25,000 square feet. The first limits applied to 2024, owners filed their first compliance reports by 1 May 2025, and stricter limits begin in 2030.
Credit
New York City Council; NYC Department of Buildings
Watch for
AI runs heating and cooling
A Schneider Electric study says AI control of a building management system cuts heating, ventilation and air-conditioning (HVAC) energy by 15% to 27%, worth $13,600 to $49,300 a year per building. The figures come mainly from computer models of one office building placed in Brisbane, Miami and Mumbai. Memoori, an independent analyst firm, wrote in April 2026 that vendors usually report savings of 20% to 50% while independent evaluators find 3% to 15%.
Achieved whenIndependent measurement in occupied buildings, such as a utility or state program evaluation, confirms savings of that size.
Claimed by
Schneider Electric, September 2026
Lifts that report faults
KONE says connecting lifts and escalators to remote sensors and AI analysis brought 40% fewer breakdown callouts from customers, 40% fewer people trapped, and 70% more faults found before customers noticed. The figures appear in a trade-press case study that does not give their source.
Achieved whenLift inspectors, a regulator or building owners' audited records confirm the reductions.
Claimed by
KONE, reported by Plant Services, October 2025
Open
01
Name the building's data points
A tool that maps the short, cryptic names of a building's control points, such as "AHU1_SAT_SP" for an air handler's supply air temperature setpoint, to the Brick schema, an open vocabulary that labels building data the same way in every building. With points labeled, analysis software works across buildings without a person relabeling each one.
The briefCredit · unclaimed02
Check controls against Guideline 36
An open tool that reads months of trend logs from a building's air handlers and checks, step by step, whether they follow ASHRAE Guideline 36, a published set of standard control sequences for heating, ventilation and air conditioning, and reports where operation has drifted from it.
The briefCredit · unclaimed
Open 01 · the brief
Name the building's data points
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A tool that maps the short, cryptic names of a building's control points, such as "AHU1_SAT_SP" for an air handler's supply air temperature setpoint, to the Brick schema, an open vocabulary that labels building data the same way in every building. With points labeled, analysis software works across buildings without a person relabeling each one.
Why it is still open
In a 2025 report from Pacific Northwest National Laboratory (PNNL), the best method tested labeled 35.6% of more than 7,429 point names in eight buildings correctly, judged against labels checked by experts; an open AI model, Llama 3, scored 26.6% on its own. A June 2026 method from Amazon researchers, Brick-DICL, claims better accuracy, but its summary gives no figures.
Built with what exists
The Brick schema and its Python library; point lists exported from building automation systems that use BACnet; a small model taught the task on one graphics chip (see the Note "One GPU to fine-tune"); PNNL's figures as the baseline to beat.
First step
Get the point list of one building whose facilities team agrees, such as a school or office, and label 200 points by hand.
Done looks like
Over 80% accuracy on at least five buildings the tool was not tuned on, with expert-checked labels released for at least one of them.
Open 02 · the brief
Check controls against Guideline 36
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
An open tool that reads months of trend logs from a building's air handlers and checks, step by step, whether they follow ASHRAE Guideline 36, a published set of standard control sequences for heating, ventilation and air conditioning, and reports where operation has drifted from it.
Why it is still open
PNNL's open framework for this kind of check, ConStrain, describes its library as "a preliminary development and implementation", with a handful of checks such as supply air temperature control. Lawrence Berkeley National Laboratory's Guideline 36 Conformance Test, released in December 2025, tests control makers' logic, not trend logs from running buildings.
Built with what exists
ConStrain; the labeled fault data curated by the US Department of Energy and Lawrence Berkeley National Laboratory, covering seven common HVAC systems in 257 faulted and fault-free states over a full year; Python; an AI coding agent such as Claude Code to draft each check from the guideline's text, for a person to review.
First step
Write one sequence, such as supply air temperature reset, as a ConStrain check and run it on a year of the fault data.
Done looks like