Industries / Health / Medical devices
Manufacturing
Manufacturing is making devices in volume, the same way every time, in plants that regulators inspect.
6
Milestones achieved, from 1961 to 2026.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1961
Syringes made to throw away
Glass syringes used to be cleaned, sterilized and used again. BD mass-produced disposable syringes in 1954 for Jonas Salk's polio vaccine program for one million American children, and in 1955 Roehr Products of Waterbury, Connecticut, made the Monoject, which the trade magazine Medical Device and Diagnostic Industry (MD+DI) calls the world's first plastic disposable syringe, and sold it for 5 cents. Doctors still thought it was cheaper to sterilize and reuse glass, and MD+DI credits BD's Plastipak, introduced in 1961, with bringing the disposable plastic syringe into wide use.
LessonA throwaway product does not take over until buyers believe it costs less than cleaning and reusing the old one.
Credit
Becton, Dickinson and Company (BD); Roehr Products
1961
Lenses spun in a mold
In 1952 the Czech chemist Otto Wichterle and Drahoslav Lim made pHEMA, a plastic that takes up water, and Wichterle molded the first soft contact lenses from it five years later, but their quality was poor. At home over Christmas 1961 he built a machine from his son's Merkur construction set and a bicycle light generator to make lenses by spin casting, in which a spinning mold shapes the liquid plastic as it sets. On Christmas Day he made the first four usable spin-cast soft lenses at his kitchen table.
Credit
Otto Wichterle
1978
Factory rules for devices
On 21 July 1978 the US Food and Drug Administration (FDA) issued current good manufacturing practice (CGMP) rules for medical devices: requirements for how device makers run and control their plants. They took effect on 18 December 1978 as part 820 of the US Code of Federal Regulations. In 1996 the FDA rewrote them as the Quality System regulation, which covered the methods, facilities and controls used to design, make, package, label, store, install and service devices.
Credit
FDA
2017
A hurricane stalls device plants
Hurricane Maria hit Puerto Rico in September 2017. In October the FDA Commissioner, Scott Gottlieb, said the island had more than 50 plants making medical devices, and that most, if not all, were still running on generator power and could not return to the output they had before the storm.
LessonWhen many plants that make a device sit in one place, one storm can threaten its supply.
Credit
FDA, as reported by the American Hospital Association
2026
US rules adopt ISO 13485
On 2 February 2026 the FDA's Quality Management System Regulation (QMSR) took effect. It replaces most of the FDA's own quality rules with ISO 13485:2016, the international standard for quality management at device makers, which the International Organization for Standardization (ISO) first issued in 1996. The FDA says ISO 13485 is used by many regulators and in the Medical Device Single Audit Program (MDSAP), in which the FDA and regulators from four other countries take part and the FDA accepts certain third-party audits of a plant in place of its own routine inspections.
Credit
FDA; ISO
2026
Hospital-made implant cleared
On 18 June 2026 the FDA cleared the 3D MAC Titanium Cranial Plate System, a 3D-printed titanium plate that repairs the skull, made by the 3D Medical Applications Center (3D MAC) at Walter Reed National Military Medical Center. The US Army is the applicant of record, and the company 3D Systems helped the center set up its quality system and validate its printing process. The trade site 3D Printing Industry reports it as the first time the FDA has cleared an implant produced by a point-of-care institution, meaning a hospital that makes devices for its own patients.
Credit
Walter Reed's 3D Medical Applications Center; Defense Health Agency; 3D Systems
Watch for
Optical inspection of implants
Norman Noble, a contract maker of implants, says it has added an automated 3D optical measuring system that scans implant surfaces with a pivoting light head. It is meant for parts with small diameters, steep angles or shiny surfaces, which are hard to measure, and the company says it measures them "with unparalleled accuracy and precision". It gave no figures.
Achieved whena customer or a lab outside the company measures the same implants with this system and with a contact measuring machine and publishes how closely the two agree and how well each repeats.
Claimed by
Norman Noble (Annie Wolfe, director of quality), September 2025
Open
01
Teach a robot tubing joints
A low-cost robot arm that joins plastic medical tubing to a connector: it picks up a cut length of tube, pushes it onto the connector, applies a UV-curing adhesive and cures it under a lamp. It learns the job from recorded demonstrations. The joints are test pieces only and are never used on anyone.
The briefCredit · unclaimed02
Map single-plant devices
A public table that takes each device on the FDA's medical device shortage list, which names each shortage by FDA product code, and counts the registered plants worldwide that list that product code in the FDA's establishment registration and device listing files. It flags the codes made at only one or two plants and the countries they are in.
The briefCredit · unclaimed
Open 01 · the brief
Teach a robot tubing joints
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A low-cost robot arm that joins plastic medical tubing to a connector: it picks up a cut length of tube, pushes it onto the connector, applies a UV-curing adhesive and cures it under a lamp. It learns the job from recorded demonstrations. The joints are test pieces only and are never used on anyone.
Why it is still open
Joining tubes to valves and connectors is mostly hand work at low volumes. In Assembly magazine, Howie Speiden of Sortimat Technology explained that tubing bends, stretches and keeps the curl of its reel, and said "the vast majority of lower volume assemblies are produced with manual labor and benchtop tooling". That quote is from 2009. Robot-learning research on flexible, cord-like objects works on wires and ropes, as in the 2026 WireCraft benchmark for industrial wire handling. The closest learned assembly found, by Kernbach and colleagues in February 2026, plugged rigid wire-harness connectors together with over 90% success after up to 300 demonstrations on an industrial arm. A search of arXiv and GitHub found no published robot that learned to assemble medical tubing joints and had them pull-tested.
Built with what exists
Hugging Face's LeRobot library and its low-cost SO-101 arm; open robot policies such as ACT or SmolVLA, or NVIDIA's GR00T models, which learn a task from a few dozen demonstrations (see the Note "Five demonstrations per task", the Note "No download" and the Note "A real production line"); PVC tubing and plastic luer connectors bought as parts; a UV lamp; a digital force gauge on a manual test stand.
First step
Make 30 joints through the arm's leader arm while recording them, and pull-test 10 hand-made joints to set the baseline.
Done looks like
100 joints made by the robot and 100 made by hand from the same batch of parts, each pulled apart on the force gauge with every failure force published. The robot's median failure force is within 10% of the hand-made median, the cycle time per joint is reported, and the robot runs are filmed.
Open 02 · the brief
Map single-plant devices
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public table that takes each device on the FDA's medical device shortage list, which names each shortage by FDA product code, and counts the registered plants worldwide that list that product code in the FDA's establishment registration and device listing files. It flags the codes made at only one or two plants and the countries they are in.
Why it is still open
In July 2024 the US Department of Health and Human Services' planning office (ASPE) matched 14,117 US device plants from the same FDA files against the federal government's natural-hazard risk index. It did not break the plants down by product or cover plants abroad, and it wrote that "similar methods could be applied to examine other elements of the supply chain or product types". A 2022 study in Health Affairs, led by Trinidad Beleche of the same department with FDA staff, counted 61 device shortages from January 2006 to July 2020 and their causes, not the plants behind each product.
First step
Download the current registration and listing files and count the plants for 10 product codes on the shortage list by hand.
Done looks like
every product code on the shortage list on a stated date has a count of plants and countries, with each plant's role. A second person rechecks 50 random rows against the FDA files and agrees with at least 95% of them. The table and code are public and refreshed monthly for three months.