BRENNEN

Industries / Construction and property / Real estate / Home inspection

Roof and exterior

This is the check of everything that keeps weather out of a house: the roof, the chimney, the walls' outer skin, decks and balconies, and the ground around the house.

5

Milestones achieved, from 1995 to 2024.

3

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1995

    Sealed stucco hides rot

    EIFS (exterior insulation and finish system), often called synthetic stucco, is a thin coat of plaster over foam board that seals a wall like a skin. In August 1995 Allen Golden, assistant director of the building inspections office in New Hanover County, North Carolina, reported that nearly all of the area's 3,200 EIFS-clad houses might hold damaging moisture inside their walls: he had probed 31 houses and found too much moisture in all but two. Probe tests later found moisture problems in 98% of 300 randomly chosen EIFS houses across the state, by the Journal of Light Construction's 1996 account. The first class action against EIFS makers was filed in North Carolina in 1995, and North Carolina and Georgia later banned the "barrier" type, which gives trapped water no way to drain.

    LessonA sealed wall can look sound while the frame behind it rots, so a visual check cannot clear it.

    jlconline.cominsurancejournal.comprobuilder.com

    Credit

    Allen Golden, New Hanover County building inspections

  2. 2011

    Leaky homes get a method

    New Zealand built many houses from the late 1980s to the mid-2000s with plaster-style "monolithic" cladding that let water in and held it, the problem known there as leaky homes. In May 2011 the Department of Building and Housing published a guide to diagnosing them in steps: look, then scan for moisture without making holes, then drill and compare the timber's moisture with a dry reference point on the same house (typically 9 to 14%), and only then cut out samples. It treats 18% moisture as the generally recognised safe level and warns that meters can read low while advanced decay is present. The government's consumer site says the standard pre-purchase inspection, NZS 4306:2005, is visual and will not find problems behind finished surfaces.

    LessonA buyer's visual inspection and a leak diagnosis are different jobs, and the standard inspection does only the first.

    building.govt.nzconsumerprotection.govt.nz

    Credit

    Department of Building and Housing, now the Ministry of Business, Innovation and Employment

  3. 2018

    Balconies inspected by law

    On 16 June 2015 a balcony fell from an apartment building on Kittredge Street in Berkeley, California, and six people were killed. California's SB 721, chaptered in September 2018, requires wood-supported balconies, decks, stairs and walkways more than six feet above the ground, on buildings with three or more apartments, to be inspected by 1 January 2025 and every six years after. The inspector must examine at least 15% of each type and write a report with photographs that sets a baseline for the next inspection.

    LessonThe law counts flashings, membranes and sealants as part of what must be inspected, because they are what keep water off the wood.

    leginfo.legislature.ca.govjlconline.com

    Credit

    California state senators Jerry Hill and Nancy Skinner

  4. 2021

    Fire zones checked at sale

    California's defensible space law requires vegetation to be managed for 100 feet around a building in wildfire areas. From 1 July 2021 a seller of a home in a high or very high fire hazard severity zone must give the buyer documentation that the property complies; if the seller has none, the buyer must agree to obtain it, within one year of closing where an agency offers the inspection.

    leginfo.legislature.ca.govleginfo.legislature.ca.gov

    Credit

    California Legislature (Civil Code section 1102.19)

  5. 2024

    Chimney checks need a camera

    NFPA 211, the US standard for chimneys and fireplaces, sets three levels of chimney inspection. A home inspector gives Level I, a look at the parts that are easy to reach; Level II, which adds attics, crawl spaces and basements, is tied to the sale or transfer of a property. The 2024 edition says a Level II inspection must view the inside of every flue liner with image-scanning equipment. The committee's stated reason was that the old words "or other means" had been read to allow a flashlight and a mirror.

    LessonLoose wording in a standard let the cheapest method pass as enough.

    structuretech.com

    Credit

    NFPA 211 technical committee

Watch for

  1. AI scores roof condition

    ScanShield AI says its software reads drone and ground photos, identifies roof damage and produces standardized condition scores and inspection reports. It announced a nationwide rollout after a six-month pilot with Fortress Roofing of Kennesaw, Georgia, which reported shorter reporting time; no accuracy figures were given.

    Achieved whenan outside party publishes how its damage calls and scores compare with hand inspections of the same roofs.

    roofingcontractor.com

    Claimed by

    ScanShield AI, March 2026

  2. Damage flagged, inspector decides

    SkyeBrowse says its Roof Damage Analysis reviews up to 24 images from one drone flight in about 20 seconds and marks hail hits, wind creases, lifted shingles and other damage as "likely" or "possible"; the inspector accepts or rejects each mark before it reaches the report, and the company calls the scan a screening aid.

    Achieved whenhit and miss rates against roofs checked by hand are published by someone other than SkyeBrowse.

    dronexl.co

    Claimed by

    SkyeBrowse, November 2026

  3. A five-foot ember zone

    California law now calls for an "ember-resistant zone" within five feet of a building, attached decks included, where materials likely to be lit by flying embers are removed. It starts for new buildings only when the state Board of Forestry updates its rules, and for existing buildings three years later; CAL FIRE may not change its inspection forms until the State Fire Marshal finds the money has been provided.

    Achieved whenthe board's rules take effect and defensible space inspections check the five-foot zone.

    leginfo.legislature.ca.gov

    Claimed by

    California Legislature (AB 1455), October 2025

Open

  1. 01

    Grade slope from a phone

    A phone app that scans the ground along each wall of a house and reports how far the soil falls in the first 10 feet (3 m) from the foundation, flagging any side that falls less than the code minimum.

    The brief
    Credit · unclaimed
  2. 02

    Tell synthetic stucco by sound

    A phone app that records a tap on a stucco wall, adds a photo, and says whether the wall is EIFS (thin plaster over foam) or traditional hard-coat cement stucco.

    The brief
    Credit · unclaimed

Open 01 · the brief

Grade slope from a phone

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A phone app that scans the ground along each wall of a house and reports how far the soil falls in the first 10 feet (3 m) from the foundation, flagging any side that falls less than the code minimum.

Why it is still open

The California Residential Code, following the International Residential Code (IRC) section R401.3, requires the ground to fall at least 6 inches (152 mm) within the first 10 feet, and paved surfaces to slope 2% away. A 2025 test of iPhone 14 Pro lidar on outdoor terrain found a vertical error (RMSE) of 0.16 m even with reference points every 20 m, about the size of the whole 6-inch fall. Phone lidar has been tested on paved curb ramps, where a Mountain-Plains Consortium study found an iPhone 13 Pro generally effective against a survey-grade Trimble TX8 scanner but with some variability in slope readings. This research found no test of phone scans against a level on the soil around houses.

meet.crossbeam-permits.comncbi.nlm.nih.govugpti.org

Built with what exists

An iPhone or iPad Pro with a lidar sensor; the 3D Scanner App (Laan Labs) or Apple's ARKit; Python with Open3D to fit the ground surface; a 10-foot straightedge with a digital level, or a rotating laser level, as the reference.

  1. First step

    Measure the four sides of one house with the phone and with a level this month, and publish the differences.

  2. Done looks like

    100 house sides measured both ways, with the app within 1 inch (25 mm) of the level's reading on at least 90 of them and every side that fails the 6-inch rule flagged; scans, readings and misses published.

Open 02 · the brief

Tell synthetic stucco by sound

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A phone app that records a tap on a stucco wall, adds a photo, and says whether the wall is EIFS (thin plaster over foam) or traditional hard-coat cement stucco.

Why it is still open

The American Society of Home Inspectors' guidance says telling the two apart is "largely a tactile experience" of tapping and pressing, with "no substitute for experience". This research found no published sound or image classifier for it.

homeinspector.org

Built with what exists

A phone microphone; Google's YAMNet audio model or a small classifier in scikit-learn; wall photos; the cladding type confirmed from building permits, builders' records or sample boards of known make.

  1. First step

    Record taps on sample boards of both systems at a building-supply yard or a stucco contractor's shop.

  2. Done looks like

    A public set of 200 walls with tap recordings, photos and confirmed cladding type, and a classifier that names the type correctly on at least 95% of 50 walls it has not seen, with every miss listed.