BRENNEN

Industries / Construction and property / Real estate / Home inspection

Electrical, plumbing and heating

This work checks the wiring, pipes, water heater, furnace and air conditioning in working order, and records what each one is, how old it is and what is wrong with it.

5

Milestones achieved, from 1989 to 2011.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1989

    Water heaters strapped for quakes

    A law added to California's Health and Safety Code in 1989 requires every home water heater, new, replacement or existing, to be braced, anchored or strapped so that it does not fall over or slide in an earthquake. Under the current text, amended in 2003, the seller of any house with a water heater must certify to the buyer in writing that the heater complies, so the strapping comes up at every sale.

    leginfo.legislature.ca.gov

    Credit

    California Legislature

  2. 2005

    Alarms checked at every sale

    In January 2005 Nicole Garofalo, aged 7, of Plymouth, Massachusetts, died of carbon monoxide poisoning after a snowdrift blocked her home's heating vent. Carbon monoxide is a colorless, odorless gas given off by burning fuel. Governor Mitt Romney signed "Nicole's Law" on 4 November 2005. It requires carbon monoxide alarms in homes with a furnace, boiler, water heater, fireplace or other fuel-burning equipment, or with enclosed parking, and it requires the local fire chief to inspect every home for compliance when it is sold. Massachusetts sellers already had to fit approved smoke detectors before a sale.

    LessonTying a safety check to the sale reaches each house in turn without a separate inspection program.

    malegislature.govberkeleybeacon.comsecuritysales.commalegislature.gov

    Credit

    Massachusetts General Court

  3. 2007

    A table of system lifespans

    In the summer of 2006 the National Association of Home Builders (NAHB) asked manufacturers, trade associations and researchers by telephone how long the parts of a house last. Its report of February 2007, sponsored by Bank of America Home Equity, updated one from 1993. By its figures furnaces last 15 to 20 years on average, heat pumps 16 years, air conditioners 10 to 15 years and electric or gas tank water heaters about 10 years. The American Society of Home Inspectors (ASHI) summarized the study for its members.

    LessonThe numbers are estimates from a phone survey, not counts of real failures, and the report says to use them "as a general guideline only".

    standards.nsf.orghomeinspector.org

    Credit

    NAHB Economics Group

  4. 2007

    France checks gas at sale

    A French government order (arrêté) of 6 April 2007 set the form and method of a report on a home's indoor gas installation. A seller in France must hand the buyer this report if the gas installation is more than 15 years old, and a matching report if the electrical installation is more than 15 years old. A certified diagnostician (diagnostiqueur) does the work, the report must be less than 3 years old when the sale is signed, and a seller who does not provide it cannot be released from the warranty against hidden defects. Both reports sit in a file of required checks that also covers lead, asbestos, termites and energy use.

    service-public.frservice-public.frservice-public.fr

    Credit

    French government

  5. 2011

    Orange and blue pipes settle

    Kitec, made by IPEX, is a pipe system for water and hot-water heating sold mostly in the late 1990s and early 2000s, and it is easy to spot by its bright orange (hot) and blue (cold) covering. On 3 May 2011 IPEX settled class actions in the US and Canada alleging that the system could fail early, with a fund of US$125 million. CBC News reported in January 2019 that an estimated 292,000 North Americans had Kitec in their homes, that 4,412 owners had been paid, and that $97.7 million was still unclaimed in May 2018. A Nova Scotia owner told CBC she was told she could not sell her house with Kitec in it and paid about $9,000 to replace it.

    LessonOnce a pipe is known to fail, buyers treat it as a defect whether or not it has leaked.

    prnewswire.comcbc.ca

    Credit

    IPEX; the US and Canadian courts that approved the settlement

Watch for

  1. Data tags read by AI

    Zap Consulting, which assesses damaged heating and cooling equipment for insurers, says its Zap-Scan tool reads one photo of an air conditioner's data tag (the maker's label with model and serial numbers) and gives the brand, model, serial number, age, tonnage (cooling capacity), SEER rating (seasonal efficiency) and refrigerant "in just seconds". The tool is open only to its insurance clients, and the announcement gives no accuracy figures.

    Achieved whenan outside test on data tags with known manufacture dates publishes how often it gets the age right.

    aijourn.com

    Claimed by

    Zap Consulting, June 2025

  2. Replacement ages from service records

    ServiceTitan, which sells software to home service contractors, says replacement intervals observed on its platform give a median of 17.7 years for a furnace, 15.3 for an air conditioner, 13.3 for a heat pump and 11.3 for a water heater. The water heater and air conditioner figures are longer than NAHB's 2007 estimates. The figures come from its own customers' jobs, and the sample and method are not published.

    Achieved whenan independent dataset, such as public permit records, gives similar medians, or ServiceTitan publishes its sample and method for checking.

    servicetitan.com

    Claimed by

    ServiceTitan, June 2026

Open

  1. 01

    Data-plate ages, tested

    A public set of photos of furnace, boiler, air conditioner and water heater data plates on which the maker also printed the manufacture date, and a scored test of the tools inspectors use to read the age from the serial number: decoder charts, decoder apps and AI models, each given the photo with the printed date covered.

    The brief
    Credit · unclaimed
  2. 02

    Service lives from permits

    Survival curves (the share of units still in service at each age) for tank water heaters, and for furnaces where permits name them, built from public building-permit records by measuring the years between successive replacement permits at the same address.

    The brief
    Credit · unclaimed

Open 01 · the brief

Data-plate ages, tested

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public set of photos of furnace, boiler, air conditioner and water heater data plates on which the maker also printed the manufacture date, and a scored test of the tools inspectors use to read the age from the serial number: decoder charts, decoder apps and AI models, each given the photo with the printed date covered.

Why it is still open

Many plates do not print the date, and makers code it into the serial number in different ways, so inspectors look it up in decoders such as the Building Intelligence Center's charts or SwiftReporter's page, and some now ask AI assistants. In September 2026 Reuben Saltzman of Structure Tech, a Twin Cities inspection firm, gave one photo of his own furnace, made in March 2021, to eight AI model settings: four gave March 2021, three gave the wrong year and one did not answer. Shipshape's app and Zap-Scan say they estimate equipment age from photos but publish no accuracy figures. This research found no test across many plates.

structuretech.comshipshape.aiaijourn.com

Built with what exists

Phone photos of plates on units at supply houses or appliance recyclers, taken with the owners' permission; the Building Intelligence Center and SwiftReporter decoders; open vision-language models and at least two commercial AI models; Label Studio for labeling; Python for scoring.

  1. First step

    Photograph 100 plates that show a printed date at one supply house and score two decoders and two AI models on them.

  2. Done looks like

    At least 1,000 plate photos from at least 15 makers, each with a printed date, released under an open license, and for each tool the share of plates where it gets the year right and the share where it gets the month right, by maker.

Open 02 · the brief

Service lives from permits

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

Survival curves (the share of units still in service at each age) for tank water heaters, and for furnaces where permits name them, built from public building-permit records by measuring the years between successive replacement permits at the same address.

Why it is still open

The life spans quoted in inspection reports come from surveys: NAHB's 2007 figures from a phone survey of makers and trade groups, and a 2022 Connecticut study from surveys of households in state efficiency programs. ServiceTitan's 2026 medians come from its own customers' records. This research found no study built from permit records, although a query of the City of Austin's open permit data run for this research returned 59,222 permits mentioning a water heater, issued from September 1980 to November 2026.

standards.nsf.orgenergizect.comdata.austintexas.gov

Built with what exists

Open permit datasets such as Austin's Issued Construction Permits, downloaded through the Socrata API; Python with pandas for address matching and the lifelines library for survival analysis.

  1. First step

    Download Austin's permit records, keep the "replacement of an existing water heater" permits, and count the addresses that have two or more.

  2. Done looks like

    Median, 10th and 90th percentile intervals between water heater replacement permits for at least three cities, with the share of addresses that have two or more permits, the code and method published, and a stated comparison with NAHB's figure of about 10 years. Permit intervals count only permitted replacements, so the write-up says how that limits the result.