Industries / Health / Medical devices / Hearing aids
Batteries and charging
Hearing aids run on small batteries: disposable button cells that the wearer changes every few days, or rechargeable cells sealed inside the case.
7
Milestones achieved, from 1944 to 2026.
1
To watch for: announced, not yet confirmed outside.
3
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1944
Mercury cells shrink the aid
Early vacuum-tube aids carried their batteries in a separate pack. Smaller batteries and tubes made one-piece body aids possible in the early 1940s: Paravox brought one out in 1942, Mears in 1943 and Beltone in 1944, whose Mono-Pac used mercury batteries, according to the Becker Library.
Lessonthe chemistry that shrank the aid was later banned; the US Mercury-Containing and Rechargeable Battery Management Act, approved on 13 May 1996, ended the sale of mercuric-oxide button cells.
Credit
Paravox; Mears; Beltone
1977
Cells that breathe air
A zinc-air cell uses oxygen from the air as one of its two reactants, with zinc as the other and potassium hydroxide as the electrolyte. It starts working when the wearer peels a tab off its air holes. The Becker Library dates the zinc-air hearing aid battery to 1977. It says the battery held more charge than the mercury cell and, with smaller microphones and receivers, drove sales of in-the-ear aids. Sizes go by names set by the International Electrotechnical Commission (IEC), so size 13 is PR48 and size 675 is PR44.
Lessonlabels can promise more than cells deliver. In 2024 an NHS audiology team in Swansea tested three brands of zinc-air cells and found that all fell short of their makers' stated service hours, though all met IEC standards.
Credit
the battery makers; the library names no developer
2013
Silver-zinc in the door
ZPower, of Camarillo, California, built on NASA and military research into rechargeable silver-zinc cells and released its first hearing aid product line in late 2013, NASA's Spinoff report says. Its system put a rechargeable cell and charging contacts in a replacement battery door that fit many existing aids. The cell was changed once a year, and an aid would still run on a zinc-air cell if the wearer forgot to charge.
Lessonin 2015 ZPower's vice-president Barry Freeman wrote in Hearing Review that lithium-ion "cannot be scaled down" to the smaller hearing aid sizes, and Phonak announced a lithium-ion aid the next year.
Credit
ZPower, led by Ross Dueber; NASA's Glenn (then Lewis) Research Center
2015
Mercury leaves the cells
Until 2015 the EU let button cells, hearing aid cells among them, hold up to 2% mercury by weight. From 1 October 2015 it banned button cells with more than 0.0005%. The European Commission had reported in October 2014 that mercury-free zinc-air cells for hearing aids were available and that supply was not at risk. The report said the first mercury-free hearing aid cells sold in the US, in 2010, had performance problems that were later solved, and that lifetimes were about 2–10% shorter depending on brand. The Minamata Convention on mercury, in force since 16 August 2017, banned mercury-added batteries from 2020 but still exempts button zinc-air cells with less than 2% mercury.
Lesson30 US states had passed or proposed bans first, and the Commission used their experience to judge that the EU ban could go ahead.
publications.europa.eupublications.europa.eumercuryconvention.org
Credit
European Parliament and Council; European Commission; parties to the Minamata Convention
2016
Lithium-ion sealed inside
On 27 June 2016 Sonova announced its Phonak Audéo B-R for US release that August. Sonova called it the first hearing aid with a built-in lithium-ion battery, giving 24 hours of use from a 3-hour charge, with the battery compartment sealed. Sonova said wearers of aids with disposable cells typically went through about 100 batteries a year per aid.
Lessonsealing the battery replaced battery doors with trips to the repair desk. HearingTracker reports that the battery in Oticon's Intent cannot be replaced by the user or the clinic, so the whole aid goes back for service.
Credit
Sonova (Phonak)
2023
Zinc-air left out of rules
Reese's Law, signed on 16 August 2022, led the US Consumer Product Safety Commission (CPSC) to adopt two final rules on 21 September 2023. They require secure battery compartments in consumer products and warning labels on button and coin battery packs. Zinc-air cells are excepted from both. CPSC staff found that zinc-air batteries "are not associated with an ingestion hazard", and no commenter named any consumer product that uses them other than hearing aids, which are medical devices. Hearing aid cells are still swallowed often. In T. L. Litovitz's 1985 study of 125 swallowed batteries they were the most common type (33.9%), but 89.9% of the button cells passed through the gut on their own.
Lessonthe cell swallowed most often is not the one that does the most harm. A 2010 study by Litovitz and colleagues found that the 20 mm lithium coin cell was behind most severe outcomes.
Credit
US CPSC; T. L. Litovitz
2026
Rechargeables take private sales
In the first quarter of 2026, rechargeable aids were 93% of private hearing aid sales in the UK, by the count of the British Irish Hearing Instrument Manufacturers Association (BIHIMA). They were only 5.8% of the aids fitted by the National Health Service, up from about 3.6%, a share that had barely moved over the previous year. In April 2026 Oticon still launched Verit, a premium family of aids that run on zinc-air cells, for wearers who would rather swap in a fresh cell.
Credit
BIHIMA; Oticon (Demant)
Watch for
Thirty-eight hours per charge
Sonova says its Phonak EON aids, available to order in the US from 24 August 2026, run for up to 38 hours on one charge, including 8 hours of streaming and 3 hours in very loud noise. It credits a new chip that it says is 37% more power-efficient at its speech-in-noise processing than the previous generation. Sonova's footnote says actual runtime depends on hearing loss, the sound around the wearer, streaming, the features in use and battery condition.
Achieved whena lab with no tie to Sonova measures runtime on new and year-old units under a published daily pattern and finds it within 10% of the claim.
Claimed by
Sonova, August 2026, repeated at the EUHA congress in October 2026
Open
01
Runtime with streaming, measured
A public table of how long rechargeable hearing aids actually run on one charge under three published daily patterns: quiet use, use with 4 hours of phone streaming, and loud noise with any neural-network noise mode switched on. Each aid sits in a test box playing a recorded sound day, and the run ends when its output stops.
The briefCredit · unclaimed02
Battery fade over a year
A year-long record of how runtime falls as the sealed lithium-ion batteries in hearing aids age in normal use. Units charge nightly in their own chargers and play a fixed sound program each day. Once a month each unit runs a full runtime test.
The briefCredit · unclaimed03
Who can change the battery
A public register of rechargeable hearing aids sold in the EU. For each model it records who may replace the battery (the wearer, any independent repairer, the clinic or only the maker), with what tools, at what price and how fast. It draws on makers' manuals and service terms and is checked with one teardown per model family, so readers can see where each model stands against the EU's battery replacement rules that apply from 18 February 2027.
The briefCredit · unclaimed
Open 01 · the brief
Runtime with streaming, measured
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public table of how long rechargeable hearing aids actually run on one charge under three published daily patterns: quiet use, use with 4 hours of phone streaming, and loud noise with any neural-network noise mode switched on. Each aid sits in a test box playing a recorded sound day, and the run ends when its output stops.
Why it is still open
Datasheet battery figures come from a test mode with most features switched off. A 2013 test sponsored by Widex, of six wireless aids running on zinc-air cells, found measured current drain 7% to 62% away from the datasheets in everyday use and 2% to 74% away while streaming, which more than doubled the drain in some aids. Thomas and colleagues (2024) tested only disposable zinc-air cells and called for test conditions that reflect wireless features. Makers now quote rechargeable runtimes that include streaming, such as Phonak EON's 38 hours with 8 of streaming, and no outside measurement of them was found. HearingTracker, a large review site, scores battery life from "manufacturer-reported hours".
audiologyonline.compmc.ncbi.nlm.nih.govhearinghealthmatters.orghearingtracker.com
Built with what exists
A hearing aid test box with an IEC 60318-4 ear simulator or 2 cc coupler; the International Speech Test Signal (ISTS) and recorded restaurant noise, played from a calibrated loudspeaker; a phone streaming over Made for iPhone, Android's ASHA or LE Audio; an audio interface logging the coupler signal, and Python to find the moment output stops.
First step
Run one over-the-counter rechargeable pair through the streaming pattern twice, and publish both runtimes and the setup.
Done looks like
Runtime in hours for at least 10 rechargeable models, 3 units each, under all three patterns, published beside each maker's claim. A second lab reruns three models and matches within 10%.
Open 02 · the brief
Battery fade over a year
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A year-long record of how runtime falls as the sealed lithium-ion batteries in hearing aids age in normal use. Units charge nightly in their own chargers and play a fixed sound program each day. Once a month each unit runs a full runtime test.
Why it is still open
Advice on battery fade rests on examples, not measurements. HearingTracker's guide says an aid "may" run at 85% of its new runtime after a year and that most batteries last about 5 years. Makers rate runtime on new units. The nearest study, by the Technical University of Denmark with WS Audiology (Asikainen and colleagues, Journal of Power Sources, 2025), examined batteries from aids that had failed in the field and stressed new cells in cyclic tests; it found that high discharge current and deep discharge speed up fade, but its abstract reports failure mechanisms, not runtime over a year of normal use. A Europe PMC search (November 2026) for rechargeable hearing aid battery life and capacity found no fade curves from normal use.
Built with what exists
The rig from the runtime test; smart plugs to switch chargers on a schedule; a data logger; at least five models, three units each, bought new.
First step
Buy three units of one over-the-counter rechargeable model and record their first runtime test.
Done looks like
Monthly runtime for at least 15 units over 12 months, plotted as a percentage of the first test, with the raw logs and the share of units below 80% at month 12.
Open 03 · the brief
Who can change the battery
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public register of rechargeable hearing aids sold in the EU. For each model it records who may replace the battery (the wearer, any independent repairer, the clinic or only the maker), with what tools, at what price and how fast. It draws on makers' manuals and service terms and is checked with one teardown per model family, so readers can see where each model stands against the EU's battery replacement rules that apply from 18 February 2027.
Why it is still open
Article 11 of the EU Batteries Regulation (2023/1542) says that from 18 February 2027 products with portable batteries must let the end user remove and replace them with commercially available tools. A delegated regulation adopted on 14 July 2026, (EU) 2026/1770, lets wearable devices that are too small for a safe swap, or that rely on a sealed enclosure, have batteries replaceable only by independent professionals, where that is needed for safety. It gives smartwatches, fitness trackers and smart glasses as examples of wearables and does not name hearing aids. HearingTracker reports that Oticon Intent's battery can be replaced only at an Oticon facility, not by the wearer or the clinic, and an iFixit thread on hearing aid batteries holds owners' anecdotes and general advice. No public record of who can change the battery in each model was found.
publications.europa.eupublications.europa.euhearingtracker.comifixit.com
Built with what exists
Makers' instructions for use and their warranty and service pages; the FDA's AccessGUDID device records and the EU's EUDAMED database for lists of models; a web agent such as Browser Use 1.0 to collect the pages (see the Note "Deleting 80% to start over"); an AI model to pull the terms into a table; teardown photos from repair labs.
First step
Collect the battery replacement terms in the five major makers' published warranties into one table.
Done looks like
A register of at least 30 rechargeable models from the five major makers and three over-the-counter brands, with a source for every field, published before 18 February 2027 and rechecked three months later.