Industries / Energy, water and waste / Environmental services / Hazardous waste disposal
Treatment and incineration
Treatment breaks hazardous waste down or changes it so it can do less harm, mostly by burning it at high temperature in incinerators or cement kilns, or by chemical processes that pull the dangerous parts of a molecule apart.
6
Milestones achieved, from 1971 to 2020.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1971
A national chemical waste plant
Danish municipalities agreed jointly in 1971 to start a plant in Nyborg to recover or incinerate chemical waste. Kommunekemi took waste from industry and from municipal collection schemes, burned the organic waste to make district heat and electricity, and sent residues to landfill. Denmark's national encyclopedia calls it "the first of its kind in the world."
Credit
Kommunekemi A/S and its municipal owners (later renamed NORD, then Fortum Waste Solutions, and from 2025 part of NG Nordic)
1977
Burning waste at sea
In 1977 the US Air Force used the incinerator ship Vulcanus to burn its surplus Agent Orange herbicide at sea. Through the 1970s, burning waste on ships was tested in the North Sea, the Gulf of Mexico and near Johnston Atoll, and it was sold commercially in the early 1980s.
LessonMore than 6,000 people came to an EPA hearing in Brownsville, Texas, in November 1983 to oppose the practice, and amendments to the London Convention adopted in 1993 banned burning industrial waste at sea.
Credit
Ocean Combustion Service, the Dutch company that built Vulcanus I in 1972; US Air Force
1981
The 99.99% rule
EPA's incinerator standard, first issued on 23 January 1981, requires a destruction and removal efficiency (DRE) of 99.99% for each principal organic hazardous constituent, the main hazardous chemicals the permit names for each waste feed. At most 1 kg of every 10,000 kg fed in may leave the stack. Wastes carrying the dioxin codes F020 to F023, F026 and F027 need 99.9999%.
Credit
US EPA
1999
Dioxin limits on waste burners
EPA set national limits on dioxins and furans, mercury and other metals, hydrochloric acid, chlorine gas and dust from hazardous waste incinerators and from cement kilns and lightweight aggregate kilns that burn hazardous waste as fuel. By EPA's count, in 1997 the US had 149 hazardous waste incinerator facilities, 20 of them commercial, and 18 cement plants running 38 kilns that burned hazardous waste fuels.
LessonEPA's June 2026 review counted about 160 combustors at about 90 facilities, found the limits still protective, and added limits for hydrogen fluoride and hydrogen cyanide, two gases the earlier rules did not cap.
Credit
US EPA, under the Clean Air Act and RCRA
2004
Japan breaks down stored PCBs
Japan's government-owned JESCO, set up in 2004, opened the first of five regional plants for high-concentration PCB waste in Kitakyushu in December 2004; the others followed from 2005 to 2008. PCBs (polychlorinated biphenyls) are oily insulating chemicals from old transformers and capacitors. The Tokyo plant uses hydrothermal oxidation and the other four use dechlorination, which strips the chlorine from the molecule, with plasma melting lines at two sites. By March 2022 JESCO had treated over 99.9% of the transformers and over 98.6% of the capacitors consigned to it.
LessonIn 2017 JESCO listed the search for hidden PCB equipment among the tasks still in front of it.
Credit
Japan Environmental Storage & Safety Corporation (JESCO)
2020
Foam burning halted in Cohoes
Researchers led by David Bond of Bennington College reported in April 2020 that PFAS levels in soil and water near the Norlite hazardous waste incinerator in Cohoes, New York, fell with distance from the plant, and that PFOS was about twice as high downwind as upwind. The plant had burned PFAS firefighting foam under a Defense Department contract and stopped in December 2019. In November 2020 New York banned burning such foam in designated environmental justice areas, a law written for Cohoes.
LessonThe state's regulator read the same data as consistent with low urban background, so sampling downwind of a plant can raise a question that a destruction rate on paper does not settle.
Credit
David Bond and colleagues, Bennington College; New York State Legislature
Watch for
Incinerators that destroy PFAS
Veolia says two test campaigns at its Port Arthur, Texas, hazardous waste incinerator, in July and October 2024, showed it destroys more than 99% of target PFAS and up to 99.9999% of PFOS and PFHxS, with no detectable target PFAS in 41 of 45 ash, slag and filter-cake samples. The stack testing firm AECOM and the laboratory Eurofins worked with Veolia on the tests. Its own report shows tetrafluoromethane (CF4), a small fluorinated gas, was less than 50% destroyed, which it says fits predictions that CF4 needs temperatures above 2,550 °F (about 1,400 °C). The Defense Department's March 2026 disposal guidance cites the study.
Achieved whena regulator or another party not paid by the operator samples the stack and residues itself, accounts for where the fluorine went, and gets matching results.
info.veolianorthamerica.comenvirotecmagazine.comwastedive.com
Claimed by
Veolia, May 2025
Open
01
One table of incinerator tests
A public table of the latest stack test for each of the roughly 160 US hazardous waste combustors: dioxins and furans, mercury, hydrochloric acid and chlorine, dust, and the destruction efficiency for the named test chemicals, each value set next to its legal limit and linked to the page of the test report it came from.
The briefCredit · unclaimed02
A scoreboard for PCB deadlines
A country-by-country table of progress toward the Stockholm Convention's 2028 goal for PCBs, built from the national reports parties file: metric tons of PCB equipment and waste found, metric tons destroyed and by what method (incineration, dechlorination or export), and what remains, with every figure linked to its report page.
The briefCredit · unclaimed
Open 01 · the brief
One table of incinerator tests
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public table of the latest stack test for each of the roughly 160 US hazardous waste combustors: dioxins and furans, mercury, hydrochloric acid and chlorine, dust, and the destruction efficiency for the named test chemicals, each value set next to its legal limit and linked to the page of the test report it came from.
Why it is still open
The last full compilation of incinerator test reports is EPA's own database for writing the rules, first drafted in November 1995. Each combustor must repeat its comprehensive performance test within 61 months of the last one, but results went to regulators on paper or as PDFs; electronic reporting through EPA's Electronic Reporting Tool starts only on 1 September 2026. EPA's June 2026 review relied on an "RTR emissions dataset" built for risk modeling and kept in its rulemaking docket. A search for an outside compilation by environmental groups or researchers found none.
archive.epa.govlaw.cornell.edulaw.cornell.edufederalregister.gov
Built with what exists
Test reports that regulators already post, such as EPA's copy of Veolia's 2014 Sauget, Illinois, report; Louisiana's standard summary tables, which list the results a report must give; EPA docket EPA-HQ-OAR-2004-0022 on regulations.gov; pdftotext; a model built for long-document extraction, such as Muse Ember (see the Note "The jobs agents repeat"); an agent that cites the page behind each value (see the Note "Findings that cite notes"); DuckDB.
First step
Fill Louisiana's summary tables from Veolia Sauget's posted 2014 report and note which values were hard to find.
Done looks like
At least 100 of the roughly 160 combustors listed with their latest test, every value linked to a report page, and a second person's check of 50 random values finds at least 48 correct.
Open 02 · the brief
A scoreboard for PCB deadlines
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A country-by-country table of progress toward the Stockholm Convention's 2028 goal for PCBs, built from the national reports parties file: metric tons of PCB equipment and waste found, metric tons destroyed and by what method (incineration, dechlorination or export), and what remains, with every figure linked to its report page.
Why it is still open
The last independent tally, by Lisa Melymuk, Miriam Diamond, Veena Singla and colleagues in 2022, found only 30% of parties on track for 2028, 42% not knowing how much PCB they hold or where, and more than 10 million metric tons of PCB-containing material left worldwide. The convention's secretariat is preparing its own report on progress toward eliminating PCBs for the parties' thirteenth meeting; a secretariat slide of 16 December 2025 marked it "under development." A search found no newer country-by-country tally.
Built with what exists
National reports under the Stockholm Convention; a model that answers the same fixed questions of every report in one pass, such as Gemini Decision 1 (see the Note "A thousand questions, one pass"); a spreadsheet; the 2022 study's method as a template.
First step
Take ten national reports and record their PCB inventory and destruction figures by hand, to fix the questions before any automation.
Done looks like
Every party with a filed report covered, each figure linked to its page, and the 2022 study's 30% on-track share reproduced within 5 percentage points when the method is run on the same reporting round.