Industries / Construction and property / Commercial and residential construction / Glazing
Replacement
Replacement is the work of renewing the windows and glass in existing buildings: repairing old sash, adding storm windows, replacing whole windows or only their sealed glass, and dealing with what comes out.
5
Milestones achieved, from 1981 to 2014.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1981
Repair before replacing
The US National Park Service's Preservation Brief 9, "The Repair of Historic Wooden Windows" by John H. Myers (1981), set out how to judge old windows unit by unit and grouped repairs into three classes: routine maintenance, such as reglazing with a bed of putty under the glass and a beveled bead over it; structural stabilization, such as consolidating decayed wood; and splices and parts replacement. It applies the Secretary of the Interior's Standards for Rehabilitation, which call for repairing and keeping original features wherever possible. It says repair can still pay where the share of replaced parts is low or few windows need it, and that a repaired window should be weatherstripped to cut air leakage. The Park Service still publishes it among its Preservation Briefs.
Credit
John H. Myers, US National Park Service
2002
Replacement windows need approval
In England and Wales, the Building (Amendment) Regulations 2001, in force from 1 April 2002, made fitting a window, rooflight, roof window or mostly glazed door in an existing home "building work" under Part L, the rules on conserving fuel and power, so replacements had to meet energy requirements and be approved. In April 2002 the government also authorised FENSA (the Fenestration Self-Assessment Scheme), the first competent person scheme for window and door installers: a registered firm certifies its own work and FENSA notifies the local building control office, instead of an inspector visiting. FENSA says it had issued more than 13 million certificates by 2018.
Credit
UK government; FENSA
2010
Old glass rebuilt on site
All 6,514 double-hung windows of the Empire State Building in New York were rebuilt in a workshop inside the building instead of being replaced. Crews removed windows at night; the glass was taken out of the frames, cleaned and reassembled with new spacers, a suspended coated film and a gas fill into insulating glass units, and refitted in the existing frames. Serious Materials did the work for Johnson Controls and finished in October 2010, after seven months. By the owner's and contractors' figures, 96% of the glass and frames was reused, each window cost about $700 against about $2,500 for a comparable new one, and the units were expected to go from about R-2 to between R-5 and R-8 in insulation value. The windows were one of eight measures in a retrofit that the owner says has met its guaranteed 38% cut in energy use every year since 2010.
Credit
Serious Materials; Johnson Controls; Empire State Building Company
2012
Retrofits rival new windows
The National Trust for Historic Preservation's Preservation Green Lab, with Ecotope and the Cascadia Green Building Council, simulated a typical older house in Boston, Atlanta, Chicago, Phoenix and Portland, Oregon, before and after seven window upgrades, from weatherstripping to new high-performance replacement windows. In every city at least one, and often two, of the cheaper measures saved energy within the range expected of new windows: interior window panels, exterior storm windows with insulating cellular shades, and sometimes exterior storm windows alone. Almost every retrofit except weatherstripping and surface films gave a better average return on investment than replacement. The report, "Saving Windows, Saving Money", warns that its percentages are for comparing measures, not for predicting a home's savings.
LessonKeeping an old window and adding a layer to it can save nearly as much energy as replacing it, for much less money.
Credit
Preservation Green Lab, Ecotope and Cascadia Green Building Council, with funding from the National Park Service
2014
Low-e storms measured
A storm window is a second window fitted inside or outside an existing one; a low-e storm has a thin coating that reflects heat. Pacific Northwest National Laboratory (PNNL) measured them in its Lab Homes, a matched pair of factory-built houses on its campus with identical double-pane, clear-glass aluminum windows. Exterior low-e storm panels saved about 10% of annual heating and cooling energy (May 2014). Interior low-e storms over 74% of the window area saved 8.1% in the heating season and 4.2% in the cooling season, about 7.8% or 1,006 kWh a year after modeling (October 2015), mainly by cutting heat flow through the glass rather than air leakage, and the researchers expect leakier homes to save more. ENERGY STAR's first storm-window specification, Version 1.0 of September 2018, requires low-e glass with an emissivity of 0.22 or less, limits on air leakage, and testing in recognized laboratories.
Credit
Jake Knox and Sarah Widder; J. M. Petersen, K. A. Cort and colleagues (PNNL); US Environmental Protection Agency
Watch for
Old windows back into float
In a pilot called Windows of Opportunities, launched in mid-2025 and led by the Zurich University of Applied Sciences (ZHAW) with the Swiss glassmaker Glas Trösch, 375 window sashes were taken from a residential building in Winterthur; installers separated the insulating glass from the PVC frames by hand, a recycler crushed and cleaned the glass, and the cullet (crushed glass) was checked for purity and remelted into new float glass. The partners call it the first documented chain of its kind in Switzerland and say every step works, though slowly, because much of it was done by hand. In July 2025 Richard Calcutt, who runs closed-loop recycling for Saint-Gobain in the UK, said less than 1% of post-consumer float glass in Europe is recycled into new float glass, and that Saint-Gobain aims for 40% by 2030.
Achieved whenthe pilot's tonnages and cullet test results are published, or an outside body reports how much end-of-life window glass a country remelts into flat glass each year.
Claimed by
Glas Trösch and ZHAW, March 2026; Saint-Gobain, July 2025
Open
01
Where old window glass goes
A weighed tally of what happens to the glass from replaced windows in one metropolitan area over a year: how many tonnes come out, and how much is landfilled, crushed for fill or aggregate, sent to bottle or glass-fiber makers, or remelted into new flat glass, with the reasons loads were turned away.
The briefCredit · unclaimed02
Failed seals spotted in photos
An open set of photographs of sealed double- and triple-glazed units in homes, each labeled clear, fogged, or hazy with mineral deposits once both outer faces have been cleaned, and a model that flags failed units from a phone photo. Test alongside it whether a clip-on thermal camera shows failed units, as some inspectors suggest. Ground-floor windows only.
The briefCredit · unclaimed
Open 01 · the brief
Where old window glass goes
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A weighed tally of what happens to the glass from replaced windows in one metropolitan area over a year: how many tonnes come out, and how much is landfilled, crushed for fill or aggregate, sent to bottle or glass-fiber makers, or remelted into new flat glass, with the reasons loads were turned away.
Why it is still open
The US Environmental Protection Agency's estimates of construction and demolition debris cover steel, wood, drywall and plaster, brick and clay tile, asphalt shingles, concrete and asphalt concrete, and leave glass out. In Europe, Saint-Gobain says less than 1% of post-consumer float glass returns to float glass, and the 2026 Swiss pilot published no tonnages. An open-source calculator on GitHub, VITRIFY, compares reuse and recycling routes for insulating glass units but holds no field data. A November 2026 GitHub search for "glass recycling window" found nothing else.
Built with what exists
Delivery and disposal tickets from window installers and waste haulers; a platform scale at an installer's yard for job-level checks; a low-cost AI model that reads tickets into a table, checked by a person (see the Note "The jobs agents repeat"); a spreadsheet or Python.
First step
Ask five window-replacement firms in one city where their old units go, and weigh the intact old units from three jobs at an installer's yard, without breaking or scraping them.
Done looks like
Tickets from at least 200 replacement jobs by at least 10 installers in one area, giving the tonnes of glass per window and the share sent to each destination, with the totals checked against two haulers' own records.
Open 02 · the brief
Failed seals spotted in photos
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
An open set of photographs of sealed double- and triple-glazed units in homes, each labeled clear, fogged, or hazy with mineral deposits once both outer faces have been cleaned, and a model that flags failed units from a phone photo. Test alongside it whether a clip-on thermal camera shows failed units, as some inspectors suggest. Ground-floor windows only.
Why it is still open
Home inspection standards of practice exclude identifying failed seals, because a newly failed unit can look normal and fog may be hidden by insect screens or dirty glass, writes Reuben Saltzman, a Minneapolis home inspector. Roboflow sells camera inspection of insulating glass units on the factory line, before glazing, not of installed windows. Searches of the web, GitHub and Crossref in November 2026 found no published data set or model for installed units.
Built with what exists
Phone cameras; a clip-on thermal camera such as the FLIR One; CVAT for labeling; an open image model such as Ultralytics YOLO; a fixed protocol of repeat photos after quick changes in temperature, when Saltzman says fog appears.
First step
Photograph every ground-floor pane in five homes, clean both faces of those that look hazy, photograph them again and label them.
Done looks like
At least 3,000 labeled panes from at least 60 homes, with labels checked by a second person; a model that catches at least 90% of fogged or hazy units in homes it was not trained on, with false alarms counted; and a tally of how often the thermal camera agreed.