Industries / Government, education and community / Government / Emergency services

Training and equipment

Teaching responders the job safely, and the gear that keeps them alive while they do it: breathing sets, protective clothing and cameras.

6

Milestones achieved, from 1914 to 2024.

1

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1914

    A hood for smoky air

    Garrett A. Morgan of Cleveland, Ohio, received US patent 1,113,675 on 13 October 1914 for a "breathing device": a hood fed by tubes that hang down behind the wearer, so that the open end draws cleaner air from low down, below the smoke. On 25 July 1916, after an explosion in the Cleveland Waterworks tunnel under Lake Erie, Morgan wore it into the gas-filled tunnel to rescue workers and recover bodies, according to the Encyclopedia of Cleveland History.

    patents.google.comcase.edu

    Credit

    Garrett A. Morgan

  2. 1998

    Deaths investigated for lessons

    Since 1998 NIOSH, the US federal agency for workplace safety research, has run the Fire Fighter Fatality Investigation and Prevention Program. Its investigators, many of them former firefighters, visit line-of-duty deaths and serious injuries on request, and each report names the factors that likely contributed and the actions that would prevent a repeat. By the program's February 2026 fact sheet, about 70 to 80 US firefighters die on duty each year, and it has investigated more than 700 deaths, about 40% of the total. It does not investigate cancer deaths.

    cdc.govcdc.gov

    Credit

    NIOSH

  3. 2007

    Training fire kills a cadet

    In February 2007 Racheal Wilson, a 29-year-old Baltimore fire cadet, died in a row house set on fire for a training exercise. Investigators found that dozens of national safety standards had been broken, and NIOSH's report made 10 recommendations; three midlevel commanders were fired. The department said all its live-fire training would now follow NFPA 1403, the US standard for training with real fire, and that it would no longer burn acquired structures, real buildings handed over for training. Fire Engineering magazine traces NFPA 1403 to a 1982 training fire in Boulder, Colorado, that killed two firefighters, and counted 15 instructors or students killed in live-fire training from 1982 to early 2007.

    LessonA training fire is a real fire, and the rules written after earlier deaths protect students only when instructors follow them.

    firerescue1.comfireengineering.com

    Credit

    investigations by NIOSH and the Baltimore City Fire Department

  4. 2014

    Retired gear tested in labs

    Turnout gear is the protective coat and trousers firefighters wear into fires, and US guidance retires it after 10 years. Meredith McQuerry and colleagues tested 251 used and retired garments from career and volunteer departments, both with the visual checks the standard asks for and with lab tests of heat protection, flammability, strength and water penetration. Heat protection and flammability supported a life of at least 10 years, but tear, seam and breaking strength and water penetration supported no more than 10, and the visual leak check did not agree with the lab water test.

    LessonLooking at gear does not show everything a lab test does.

    link.springer.com

    Credit

    Meredith McQuerry, Stacy Klausing, Deena Cotterill and Elizabeth Easter, in Fire Technology

  5. 2022

    Firefighting itself causes cancer

    On 1 July 2022 the International Agency for Research on Cancer (IARC), the World Health Organization's cancer agency, announced that its experts had classified occupational exposure as a firefighter as "carcinogenic to humans" (Group 1), on "sufficient evidence" of cancer in humans. A summary by Demers and colleagues appeared in The Lancet Oncology on 30 June 2022, and the full assessment is Volume 132 of the IARC Monographs.

    iarc.who.int

    Credit

    the IARC Monographs working group

  6. 2024

    Chemicals measured in the gear

    Some layers of turnout gear are treated with or made from PFAS, a large family of long-lasting fluorinated chemicals. Acting on a 2020 law, NIST measured 51 PFAS in 20 turnout gear textiles before and after the kinds of wear they meet in service. In its January 2024 report, levels rose after abrasion, heat and weathering (ultraviolet light with humidity) and were similar or lower after laundering. In water-repellent outer shells, the median total rose from 1,430 µg/kg when new to 3,500 µg/kg after abrasion and 4,420 µg/kg after heating, and fell to 963 µg/kg after laundering.

    nvlpubs.nist.gov

    Credit

    Andrew Maizel, Rick Davis and colleagues at NIST

Watch for

  1. Gear made without added PFAS

    NFPA issued Standard 1970 in October 2024; it limits PFAS and other hazardous chemicals in turnout gear through a Restricted Substances List, from 18 September 2025. Globe, a turnout gear brand of MSA Safety, said in September 2025 that it offers an ensemble certified to NFPA 1971 "made without intentionally added PFAS", with a new moisture barrier from W. L. Gore certified to both standards. In August 2025 the International Association of Fire Fighters (IAFF), the firefighters' union, warned that a "PFAS-free" moisture barrier on the market contained the brominated flame retardant DBDPE at 19 times the concentration of PFAS in older barriers, and told departments to demand proof from an independent, accredited lab.

    Achieved whenan independent accredited lab publishes results showing that named PFAS-free ensembles meet NFPA 1970's restricted substances list and keep their heat and water protection after wear and laundering as well as the gear they replace.

    blog.msafire.comiaff.org

    Claimed by

    MSA Safety (Globe) and W. L. Gore, September 2025

Open

  1. 01

    Gear damage from photos

    A phone app that photographs a turnout coat or trousers, inside and out, and flags the damage a trained inspector looks for, such as tears, worn seams, heat damage, failed closures and lost reflective trim, then predicts whether the garment would fail the lab tests for strength and water penetration. Train and check it only on gear already retired from service.

    The brief
    Credit · unclaimed
  2. 02

    A thermal image reading test

    A public test of how well firefighters read a thermal camera, the handheld infrared camera crews use to see through smoke. It is made of short thermal clips filmed in a classroom or training building with no fire: warm manikins under furniture, heaters behind walls and doors, and stage smoke. Each clip has a known answer, such as where the person is or which door has heat behind it. The same test is then given to AI vision models.

    The brief
    Credit · unclaimed

Open 01 · the brief

Gear damage from photos

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A phone app that photographs a turnout coat or trousers, inside and out, and flags the damage a trained inspector looks for, such as tears, worn seams, heat damage, failed closures and lost reflective trim, then predicts whether the garment would fail the lab tests for strength and water penetration. Train and check it only on gear already retired from service.

Why it is still open

The inspections in the standard rely on visual checks, such as holding the garment to a light or shining a flashlight through it, and in a lab study of 251 used and retired garments the visual leak check did not agree with the lab water test. Searches of GitHub and Crossref found no image model for turnout gear inspection.

link.springer.com

Built with what exists

a phone camera and a light box; an open image model fine-tuned on labeled photos; retired garments from fire departments; a textile lab that runs tear, seam and water penetration tests.

  1. First step

    Ask two local fire departments for retired gear, photograph 30 garments, and have a certified gear inspector label the damage on each photo.

  2. Done looks like

    300 retired garments photographed and then tested in the lab, with the app's pass or fail calls compared with the lab results and with a certified inspector's visual calls on the same garments, and the share of lab failures each one caught published.

Open 02 · the brief

A thermal image reading test

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public test of how well firefighters read a thermal camera, the handheld infrared camera crews use to see through smoke. It is made of short thermal clips filmed in a classroom or training building with no fire: warm manikins under furniture, heaters behind walls and doors, and stage smoke. Each clip has a known answer, such as where the person is or which door has heat behind it. The same test is then given to AI vision models.

Why it is still open

NIOSH's report on the 2007 Charleston fire called for better use of thermal cameras. A 2008 University of Maryland study by Justin Rowe, done for NIST's camera test methods, had firefighters find a fire hazard in still infrared images while contrast, brightness, resolution and noise were varied; it measured the camera's display, not how well firefighters read realistic scenes. Fire360, a June 2025 benchmark of 228 videos from firefighter training, tests AI models on scenes from training sessions and reports a single expert score for one task; it does not test firefighters reading thermal images. Searches of Crossref and arXiv found work on AI detection in thermal images but no published scored test of firefighters' reading.

stacks.cdc.govdrum.lib.umd.eduarxiv.org

Built with what exists

a firefighting thermal camera; training manikins with heating pads; space heaters; a stage smoke machine; an online survey tool; current AI vision models as a second set of test takers.

  1. First step

    Film 30 clips with three hidden heat sources in a training room and try the test on 10 firefighters.

  2. Done looks like

    200 clips with known answers, taken by at least 100 firefighters from at least five departments, with accuracy reported by question type and by years of service, and the same scores reported for at least two AI models.