Industries / Industrial equipment and services / Industrial machinery / Compressors
Piston compressors
A piston moving in a cylinder draws gas in through one valve and pushes it out through another at higher pressure; these machines reach the highest pressures of any compressor.
6
Milestones achieved, from 1776 to 2016.
2
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1776
Steam drives the blast
The first engine that Boulton & Watt built at Soho was ordered by John Wilkinson to blow the bellows of his ironworks at Broseley, England, and it was ready to run early in 1776. Neighboring ironmasters who had planned to buy older Newcomen engines waited to see it work, and its success made the firm's name in the Midlands.
Credit
James Watt and Matthew Boulton; John Wilkinson
1889
Air piped across a city
Victor Popp's company, which became the Compagnie Parisienne de l'Air Comprimé (CPAC) in 1889, sold compressed air in Paris as a public utility, first to drive pneumatic clocks and then motors, lifts and cold rooms. By 1894 it had two compressing plants, at rue Saint-Fargeau and quai de la Gare, of 13,000 horsepower in all, and 168.5 km of air pipes under the streets, by the account of the historians Mustafa Dikeç and Carlos López Galviz. By 1960 the network served nearly 10,000 customers at 5 to 6 bar. Its operator, by then called SUDAC, installed its first compressor on a customer's own site in 1973, and the network ran until 1994, when the City of Paris ended the concession.
LessonAir piped from central plants lost out to electricity and to compressors placed where the air is used.
Credit
Victor Popp; CPAC, later SUDAC
1895
A steel plate valve
On 20 November 1895 Hanns Hörbiger applied for a patent on a "friction-free guided plate valve", a thin steel plate that lifts off its seat to let gas through and drops back to seal. The patent was granted on 26 January 1897. His company's chronicle says the valve brought "an enormous increase in performance" in the compressors used in steel production at the time, and that the first blast furnace blower with Hörbiger valves outside Austria-Hungary started at the Alplerbecker Hütte in Westphalia in 1899. A one-piece plate and guide followed in 1906, and the rights to his US patent 921,892 went to Ingersoll Rand.
Credit
Hanns Hörbiger, by his company's account
1935
Pistons that never touch
A labyrinth piston compressor seals the gap around its piston with a row of fine grooves instead of rubbing rings, so the piston never touches the cylinder wall and no oil is needed inside it. Burckhardt Compression dates its first labyrinth piston compressor, sold as Laby, to 1935. The company still makes the type for gases that must stay free of oil and of wear debris from rings.
Credit
the company now called Burckhardt Compression, by its own account
1999
Hyper compressors for plastic
Low-density polyethylene, the soft plastic of film and bags, is made from ethylene gas at very high pressure. ICI chemists found it in 1933 in an experiment that reacted ethylene at high pressure and temperature. Burckhardt Compression's hyper compressors, the piston machines that feed such plants, raise ethylene to as much as 3,500 bar (50,000 psi), the company says. It says it delivered the most powerful hyper compressor then built, 23,500 kW, in 1999, and a 27,500 kW single-frame compressor in 2007.
collection.sciencemuseumgroup.org.ukburckhardtcompression.comburckhardtcompression.com
Credit
Eric Fawcett and Reginald Gibson at ICI (the chemistry); Sulzer-Burckhardt, now Burckhardt Compression (the 1999 machine)
2016
Station compressors fail most
The US National Renewable Energy Laboratory (NREL) collected maintenance records from hydrogen filling stations. In its 2016 review it reported that most maintenance was on compressors and dispensers, and that compressors had the worst record of any category, about 25 vehicle fills between failures, against a best median of about 345 for electrical parts.
LessonReviewers asked NREL to collect more detailed data on compressor failures, and NREL said it would ask its station partners for it.
Credit
Sam Sprik, Jennifer Kurtz and colleagues, NREL
Watch for
Liquid in place of pistons
The H2REF-DEMO project, led by France's mechanical industries technical center CETIM, says its system raises hydrogen pressure with a hydraulic power pack and bladder accumulators in place of a mechanical compressor. It claims 150 kg of hydrogen an hour dispensed at 350 bar for trucks, using less than 3.5 kWh per kilogram, and plans 500 hours of testing in 2026 at a station in Champagnier, France.
Achieved whenthe 500-hour results, with flow, energy per kilogram and every failure, are published and checked by someone outside the consortium.
Claimed by
the CETIM-led H2REF-DEMO consortium, December 2025
Piston packages for Hamburg
Hoerbiger says its HCP 500 package, built around an Ariel KBH piston compressor, moves more than 250 kg of hydrogen an hour, and that three will serve the Hamburg Green Hydrogen Hub, a 105 MW electrolyzer plant planned for 2027 on the site of the Moorburg coal power station.
Achieved whenthe Hamburg units are running and the plant's operator or another outside party reports their flow and availability.
Claimed by
Hoerbiger, October 2025
Open
01
Check shop compressor labels
A measured table of the air that 20 common small piston compressors, sold for homes and workshops, actually deliver at 90 psi (6.2 bar), with the power each draws, set against the figures printed on their labels and boxes.
The briefCredit · unclaimed02
Photos of failed valves
A public set of photographs of failed valve parts from piston compressors (plates, rings, springs and seats), each labeled with its failure mode, such as impact fatigue, cracking from flexing, sticking, foreign matter or liquid damage, and a phone model that names the likely mode from a photo.
The briefCredit · unclaimed
Open 01 · the brief
Check shop compressor labels
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A measured table of the air that 20 common small piston compressors, sold for homes and workshops, actually deliver at 90 psi (6.2 bar), with the power each draws, set against the figures printed on their labels and boxes.
Why it is still open
A delivered-air rating means little without the pressure it was measured at, as the engineer Richard Kinch points out on his page on true horsepower and airflow. The Journal of Light Construction's 2004 test of ten stacked-tank compressors, by Victor Rasilla, timed their recovery with a stopwatch and printed the makers' airflow figures without measuring flow. Searches found pump-up timings in forum threads, but no independent comparison of many models at one fixed pressure with a calibrated flow meter.
Built with what exists
A thermal mass flow meter made for compressed air, a pressure regulator and needle valve after the tank outlet, a plug-in power meter, a thermometer, and a laptop to log readings. Each unit runs as sold, at its own rated pressure.
First step
Borrow three popular models from a tool library or shop, test them with one flow meter, and publish the method and the logs.
Done looks like
20 models, each run warm and measured three times at 90 psi, with delivered airflow, input watts, and the ratio of measured to labeled airflow published with raw logs; a second tester repeats five of the models and lands within 5% of the first.
Open 02 · the brief
Photos of failed valves
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public set of photographs of failed valve parts from piston compressors (plates, rings, springs and seats), each labeled with its failure mode, such as impact fatigue, cracking from flexing, sticking, foreign matter or liquid damage, and a phone model that names the likely mode from a photo.
Why it is still open
Most operators report that valve failures are the largest cause of forced outages of piston compressors, Klaus Brun of Southwest Research Institute and Marybeth Nored of Apache wrote in 2012. The public fault data found are sensor recordings from test rigs, such as the EGB-250 valve-fault recordings from GIDTEC at Universidad Politécnica Salesiana, Ecuador, not photos of failed parts, and searches of Zenodo and GitHub found no labeled image set.
Built with what exists
Phone cameras and a simple light box; failed parts and repair notes from compressor valve repair shops; a pretrained image model fine-tuned with PyTorch.
First step
Ask one valve repair shop for 30 failed parts with their repair notes, and photograph each under the same light from a fixed set of angles.
Done looks like
1,000 photos of 200 failed parts from at least three shops, labeled by two experienced mechanics who agree on at least 85% of parts; a model that matches the mechanics on at least 80% of parts from a shop it was not trained on.