This work checks weights, scales, flow meters and fuel pumps against reference masses and volumes; much of it is required by law, because goods are bought and sold by weight and volume.

7

Milestones achieved, from 1889 to 2026.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1889

    One kilogram for all

    On 26 September 1889 the first General Conference on Weights and Measures sanctioned a platinum-iridium cylinder chosen by its committee as the international prototype of the kilogram, "the unit of mass". It was kept under three bell jars in a vault at the International Bureau of Weights and Measures (BIPM) outside Paris, and copies went to member countries as their national standards. For 130 years every calibrated weight in the world traced back to it through those copies.

    bipm.orgnist.gov

    Credit

    the 1st CGPM and the BIPM

  2. 1955

    A treaty for trade instruments

    States signed the Convention establishing the International Organization of Legal Metrology (OIML) in Paris on 12 October 1955, and it entered into force on 28 May 1958. Legal metrology is the part of measurement that the law controls, such as shop scales and fuel pumps. The convention charged the OIML with drafting model laws and regulations for measuring instruments, a model service for inspecting and checking them, and the technical requirements instruments must meet to be approved.

    oiml.org

    Credit

    the signatory states; the OIML

  3. 1999

    One cubic meter for gas

    When Germany's pigsar laboratory opened in Dorsten in 1993, gas meters calibrated there and in the Netherlands differed by up to 0.2%, within each laboratory's stated uncertainty but costly in trade: the partners estimate that a 0.1% difference could shift about €15 million in the Netherlands alone. In June 1999 the Dutch and German national metrology institutes, VSL and PTB, agreed to calibrate high-pressure gas meters to a single harmonized reference value, a weighted average of their independent results. France joined in 2004 and Denmark's FORCE Technology in 2013, forming EuReGa, and the 2004 comparison is registered with the BIPM as key comparison CCM.FF-K5.a.

    LessonTwo laboratories that each meet their own uncertainty can still differ enough to move money, and only regular comparison removes the gap.

    nfogm.noeuramet.org

    Credit

    VSL and PTB; EURAMET project 800 under Mijndert van der Beek of VSL

  4. 2011

    Canada restores pump checks

    Measurement Canada once examined every trade device each year, moved to every two years in the mid-1980s, and stopped requiring periodic examinations in 1994; by its own data, compliance rates have trended down by 4% to 7% since the 1980s. The Fairness at the Pumps Act, given Royal Assent on 23 March 2011, let the government appoint private "authorized service providers" to do the examinations, with the agency auditing them, and regulations proposed in 2013 would require retail gasoline pumps to be examined every two years. In 2025 Measurement Canada reports 135,771 retail petroleum devices inspected, 97% of them compliant.

    LessonCanada's government concluded that accuracy in the marketplace slips when routine checks stop, and chose private calibration firms under audit to restore them.

    gazette.gc.caised-isde.canada.ca

    Credit

    the Government of Canada and Measurement Canada

  5. 2014

    A 35-microgram slip found

    Before the kilogram was redefined, the BIPM took the international prototype out and compared it with its six official copies and with the BIPM's own working standards, the weights it used day to day to calibrate other countries' kilograms. Every working standard was lighter than at the last full check, in 1988 to 1992, so the mass unit the BIPM maintained for its calibrations was offset from the prototype by 35 micrograms. The same campaign found that the differences between the prototype and its copies had changed by an average of only 1 microgram since that check, which did not confirm the drift seen in earlier checks.

    LessonReference weights wear with use, so even the top of a calibration chain needs checking against the level above it.

    iopscience.iop.org

    Credit

    Michael Stock, Pauline Barat, Richard Davis, Alain Picard and Martin Milton of the BIPM

  6. 2019

    The kilogram leaves the vault

    From 20 May 2019, under a decision of the 26th CGPM in November 2018, the kilogram is defined by fixing the Planck constant at exactly 6.626 070 15 × 10⁻³⁴ J s, so the prototype's mass became something to measure instead of the definition. The same revision fixed the Boltzmann constant, the elementary charge and the Avogadro constant, redefining the kelvin, ampere and mole. One instrument that turns the new definition into a mass is the Kibble balance, which Bryan Kibble at NPL conceived in 1975: it balances a weight against an electromagnetic force measured with quantum electrical standards. NIST says its NIST-4 balance measured the Planck constant to within 34 parts per billion and that, since 20 May 2019, US mass calibrations trace back to it.

    bipm.orgnist.govnist.gov

    Credit

    the 26th CGPM; Bryan Kibble (NPL); NIST and other national laboratories

  7. 2026

    Three desk balances agree

    Three tabletop Kibble balances, built separately at Germany's Technische Universität Ilmenau, at PTB and at NIST, measured two sets of top-class weights from 1 mg to 10 g without seeing one another's results or the results of the weights' makers, whose accredited laboratories had calibrated them the conventional way, by comparison with reference weights. When the results were opened at a BIPM meeting in November 2025, they showed "generally good agreement", and the authors conclude that such balances can calibrate small weights at the two highest OIML accuracy classes, E1 and E2.

    nist.gov

    Credit

    Johannes Konrad and co-authors at TU Ilmenau, PTB and NIST, published in Metrologia in July 2026

Watch for

  1. Kibble balance for sale

    NIST says it has a cooperative research agreement with an American balance maker to commercialize its tabletop Kibble balance, KIBB-g2.2. The earlier KIBB-g2.0, delivered to the US Army's Redstone Arsenal in April 2024, realizes masses from 1 mg to 20 g with uncertainties of tens of micrograms, and the Army is funding larger versions up to 1 kg. NIST's Leon Chao says every mass laboratory having such balances is "not a question of if but when".

    Achieved whena manufacturer sells the instrument and a calibration laboratory outside NIST publishes calibrations made with it, or has them accepted by an accreditation body.

    nist.govnist.gov

    Claimed by

    NIST, June 2025

  2. Hydrogen flow traced to SI

    European laboratories in the H2FlowTrace project (EURAMET 23IND05, 2024 to 2027, coordinated by France's LNE-LADG) are building a direct route from SI units to flowing pure hydrogen, starting from a pressure-volume-temperature-time standard at Cesame and stepping up to 1,000 m³/h. The partners say the target uncertainty is 0.30% at about 95% confidence, planned for 2026, and that hydrogen network facilities so far rely on calibrations with other gases plus modeling.

    Achieved whencomparisons between independent hydrogen flow standards are published and registered with EURAMET or the BIPM, showing agreement within the stated uncertainties.

    nfogm.noeuramet.org

    Claimed by

    authors from VSL, PTB, FORCE Technology and Cesame-Exadebit, in a paper posted in September 2026

Open

  1. 01

    Which way pumps err

    A public dataset of retail fuel pump tests from several states or countries that records, for each test, how far the pump was off and in whose favor (more fuel than shown, or less), with an analysis of how often errors favor the station or the customer and whether errors grow with time since the last inspection.

    The brief
    Credit · unclaimed
  2. 02

    A robot runs balance checks

    A general-purpose robot arm that calibrates an ordinary laboratory balance from start to finish, following the free EURAMET calibration guide for non-automatic weighing instruments: repeated loadings of one weight, the same weight placed at the center and at four off-center spots, and test weights across the range, with readings taken over the balance's data port.

    The brief
    Credit · unclaimed

Open 01 · the brief

Which way pumps err

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public dataset of retail fuel pump tests from several states or countries that records, for each test, how far the pump was off and in whose favor (more fuel than shown, or less), with an analysis of how often errors favor the station or the customer and whether errors grow with time since the last inspection.

Why it is still open

Published figures give pass rates, not error sizes or directions. Measurement Canada reports only that 97% of 135,771 retail petroleum devices complied in 2025, and New York City's open dataset lists only devices inspected and approved per visit for its 8,066 petroleum inspection records from July 2023 to September 2026, pumps and octane samples together, with no test errors. The only analysis of direction found is a 2017 Arizona Daily Star study of more than 2,200 Arizona inspections since 2010, which found pumps shorting customers in 7.6% of inspections and favoring them in just over 12%. No study pooling several jurisdictions was found.

ised-isde.canada.cadata.cityofnewyork.ustucson.com

Built with what exists

Public-records requests to state weights-and-measures offices for retail motor-fuel dispenser test reports; the NYC Open Data API; an AI model that answers fixed-choice questions to sort free-text inspection notes, checked by hand (see the Note "A thousand questions, one pass"); Python with pandas; NIST Handbook 44, the US code of tolerances for weighing and measuring devices, for the limits each test is judged against.

  1. First step

    File records requests with three state weights-and-measures offices for five years of dispenser test results, and download the New York City dataset.

  2. Done looks like

    At least 10,000 dispenser tests from at least three jurisdictions, each with the size and sign of the error; 200 records chosen at random checked against the source documents and the error rate published; the share of tests favoring each side, with confidence intervals; data and code published.

Open 02 · the brief

A robot runs balance checks

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A general-purpose robot arm that calibrates an ordinary laboratory balance from start to finish, following the free EURAMET calibration guide for non-automatic weighing instruments: repeated loadings of one weight, the same weight placed at the center and at four off-center spots, and test weights across the range, with readings taken over the balance's data port.

Why it is still open

Robotic mass comparators have calibrated weights since 1999, when METROTEC and Mettler-Toledo installed the first commercial system, but they work inside their own cabinet on their own balance. Calibrating the balances that laboratories use every day is still done on site by a technician moving weights by hand. The balance maker Radwag showed in April 2024 a Universal Robots arm running a performance test on one of its own weighing modules, but published no results. No published test of a general-purpose robot doing a full calibration of this kind, on balances of different makes, was found.

imeko.orgeuramet.orgradwag.com

Built with what exists

A collaborative arm such as a Universal Robots UR5e, or an SO-101 arm for a first try, trained with Hugging Face's LeRobot (see the Note "No download") or an open robot model such as NVIDIA's GR00T 2 (see the Note "Five demonstrations per task"); an OIML class F1 weight set with a calibration certificate and weight forks; balances that accept commands over a serial or USB port, such as Mettler-Toledo's MT-SICS command set; Python.

  1. First step

    Script the repeatability test, ten loadings of one weight on one balance, with the arm placing the weight and the balance reporting over its data port.

  2. Done looks like

    Twenty filmed calibrations on five balances, from a 220 g analytical balance to a 6 kg bench balance, each compared with a technician's calibration of the same balance on the same day and agreeing within the combined uncertainty, with no weight dropped, and a published tally of failures and their causes.