BRENNEN

Industries / Industrial equipment and services / Industrial services / Vibration analysis

Sensors

Sensors turn a machine's shaking into an electrical signal; the usual one is an accelerometer, which measures how fast a surface speeds up and slows down as it moves.

4

Milestones achieved, from 1943 to 2024.

1

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1943

    A crystal that feels shaking

    A piezoelectric material gives off an electric charge when it is squeezed, so a crystal loaded by a small weight puts out a signal that follows the shaking. Brüel & Kjær of Nærum, Denmark, says its Type 4301 of 1943, made with Rochelle salt crystals and developed by Per V. Brüel, was the world's first commercial piezoelectric accelerometer. The company writes that the discovery of a strong piezoelectric effect in lead zirconate titanate (PZT), a ceramic, by Jaffe in the early 1950s led to its first PZT accelerometer in 1957.

    hbkworld.com

    Credit

    Per V. Brüel, Brüel & Kjær

  2. 1967

    Electronics inside the sensor

    Bob Lally, who had co-founded the original Kistler Instrument Co. in 1955, formed PCB Piezotronics in 1967 with his brother Jim to build piezoelectric sensors with their electronics inside. Electronic Design credits him with bringing to market a two-wire accelerometer with built-in electronics, sold as ICP (integrated circuit piezoelectric), and calls his 1967 paper for the ISA, "Application of Integrated Circuits to Piezoelectric Transducers," among the first published technical explanations of the idea. It says the built-in electronics made sensors cheaper, easier to use and better suited to factories, and opened markets such as monitoring the health of industrial machinery.

    electronicdesign.comendevco.com

    Credit

    Bob Lally and Jim Lally, PCB Piezotronics

  3. 2020

    Drift measured on 50 sensors

    An accelerometer's sensitivity, its electrical output for a given amount of shaking, changes slowly with time, so it has to be checked against a reference. Malcolm Porterfield of Los Alamos National Laboratory compared the calibration records of 50 Meggitt piezoelectric accelerometers (models 7250A-10 and 7250AM1-10). Within two years of the first calibration most had drifted by no more than 1.2%, all stayed within the 10% band of their rating, and sensitivity tended to rise. He wrote that extrapolating beyond two years "would be prone to large error."

    LessonRecords of drift support trust only for as many years as they cover.

    osti.gov

    Credit

    Malcolm K. Porterfield, Los Alamos National Laboratory

  4. 2024

    Chip sensors tried on bearings

    MEMS (micro-electromechanical systems) accelerometers are sensors etched into silicon chips, and they cost less than piezoelectric ones. Marek Fidali, Damian Augustyn and Jakub Ochmann of the Silesian University of Technology in Gliwice, Poland, measured 11 healthy and damaged rolling bearings with two commercial MEMS-based digital vibration sensors and a piezoelectric reference that reached 10,000 Hz. The MEMS sensors, which worked in bands up to 3,500 Hz and 4,000 Hz, detected medium and severe damage, and the one with the higher band was the more sensitive to slight damage.

    LessonA sensor's upper frequency limit decides how early it can see bearing damage.

    pmc.ncbi.nlm.nih.gov

    Credit

    Marek Fidali, Damian Augustyn and Jakub Ochmann, Silesian University of Technology

Watch for

  1. Chips to replace piezo sensors

    STMicroelectronics says its IIS3DWB10IS, a MEMS vibration sensor, measures vibration and shocks up to 200 g (200 times the acceleration of gravity) at frequencies of 10 kHz and above, runs AI models on a processing unit inside the sensor, and is "the first compelling alternative to piezosensor" for condition monitoring.

    Achieved whenan outside laboratory or user publishes a side-by-side test against a piezoelectric reference showing that it catches slight bearing damage as early.

    newsroom.st.com

    Claimed by

    STMicroelectronics, June 2026

Open

  1. 01

    Sensors re-checked after years

    A public table of how much permanently mounted accelerometers drift in real plants. Collect sensors taken off running machines after five or more years in service, recalibrate each against a reference accelerometer, and record the change in sensitivity next to the sensor's model, age, mounting and the temperatures it saw.

    The brief
    Credit · unclaimed
  2. 02

    Wide-band chips on grown damage

    A side-by-side test of the new wide-band MEMS chips against a piezoelectric reference on bearings run until they fail on a test rig, so that the damage grows by itself rather than being cut in. All sensors record at once, and the results give the recordings and the day each sensor first crossed its alarm level.

    The brief
    Credit · unclaimed

Open 01 · the brief

Sensors re-checked after years

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public table of how much permanently mounted accelerometers drift in real plants. Collect sensors taken off running machines after five or more years in service, recalibrate each against a reference accelerometer, and record the change in sensitivity next to the sensor's model, age, mounting and the temperatures it saw.

Why it is still open

The Los Alamos study of 2020 covered 50 sensors over about two years of calibration records, said that predictions beyond two years would be "prone to large error," and recommended that a third party do the calibrations. Its sensors were laboratory test sensors, not ones left on machines. A web search in November 2026 found no multi-year study of sensors removed from plant machinery.

osti.gov

Built with what exists

A back-to-back comparison calibrator, a small shaker that drives the sensor under test and a reference sensor together; a reference accelerometer with a current certificate from an accredited calibration laboratory; a data acquisition card; Python with pandas.

  1. First step

    Ask two plants or a motor repair shop for the accelerometers they are retiring this year, with their installation dates, and recalibrate the first ten.

  2. Done looks like

    At least 50 sensors with at least five years in service, each with its change in sensitivity in percent, the share that moved more than 5% from its first calibration, and the raw calibration data, published under an open license.

Open 02 · the brief

Wide-band chips on grown damage

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A side-by-side test of the new wide-band MEMS chips against a piezoelectric reference on bearings run until they fail on a test rig, so that the damage grows by itself rather than being cut in. All sensors record at once, and the results give the recordings and the day each sensor first crossed its alarm level.

Why it is still open

The 2024 Gliwice test used commercial MEMS sensors with bands up to 4,000 Hz, and damage was put into some of its bearings by hand; it found that the band decided how early slight damage showed. STMicroelectronics' 2026 claim for a chip reaching 10 kHz has no outside test. A Crossref search in November 2026 found no run-to-failure comparison of MEMS and piezoelectric sensors.

pmc.ncbi.nlm.nih.govnewsroom.st.com

Built with what exists

A bearing test rig with a motor, a shaft and a radial load, inside a guard; a piezoelectric reference accelerometer; evaluation boards for STMicroelectronics' IIS3DWB10IS and Analog Devices' ADXL1002; a multichannel data acquisition card; Python with NumPy and SciPy.

  1. First step

    Mount the two chip evaluation boards beside a piezoelectric sensor on an existing bearing rig and record a week of healthy running.

  2. Done looks like

    At least ten bearings run to failure with every sensor recording, and a table of the days of warning each sensor gave at the same false-alarm rate, published with the data.