BRENNEN

Industries / Industrial equipment and services / Industrial services / Non-destructive testing

Eddy current

Eddy current testing passes alternating current through a coil held near metal; the coil's magnetic field drives swirling electric currents in the metal, and a crack, a thin wall or a different alloy changes those currents in a way the coil can measure.

5

Milestones achieved, from 1879 to 2009.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1879

    A balance for metals

    David Edward Hughes described his induction balance in the Philosophical Magazine in July 1879, and in the same issue W. Chandler Roberts reported using it to examine alloys. Iowa State University's NDE-Ed resource says Hughes recorded changes in a coil's properties when it was placed near metals of different conductivity and magnetic permeability, the effects that eddy current testing measures. The effect behind it, electromagnetic induction, was Michael Faraday's discovery of 1831. The same resource says these effects were not put to practical use for testing materials until the Second World War, and that much of the development came in aircraft and nuclear work in the 1950s and 1960s.

    api.crossref.orgapi.crossref.orgnde-ed.org

    Credit

    David Edward Hughes

  2. 1948

    Testing instruments for industry

    Friedrich Förster, a physicist at the Kaiser Wilhelm Institute for Metal Research who had worked for years on ways to test metals without damaging them, founded his own company in Reutlingen, Germany, in 1948, to build rugged measuring and testing instruments based on electromagnetic principles. The company says his magnetic field probe became a standard part of automated eddy current and flux leakage testing systems, and it still makes eddy current testing equipment.

    foerstergroup.com

    Credit

    Friedrich Förster; Institut Dr. Foerster

  3. 1980s

    Sizing cracks under the sea

    Fatigue cracks grow in the welded joints of offshore oil platforms, and how deep they are decides how dangerous they are. Before alternating current field measurement (ACFM), such cracks under water were found and their length measured with magnetic particle inspection. Eddy current instruments of the time could not measure cracks deeper than 5 mm, and the method used for depth, alternating current potential drop, was slow under water because its probe needed very good electrical contact with the steel. A group of UK oil companies asked University College London for a method without that contact, and ACFM was developed in the 1980s. It induces a current in the steel and measures the magnetic field above it, and a sizing method built from theory turns the readings into a crack's length and depth. Certification authorities approved it for offshore inspection above and below water, and ASME's Section V has an article on it (Article 15, cited as 2006), according to an account by the technical director of TSC, a company that makes ACFM equipment. TWI later found it effective on coated steel in a feasibility study.

    qualitymag.comtwi-global.com

    Credit

    University College London, for a group of UK oil companies

  4. 1996

    Depth calls need proof

    In a pressurized water reactor, thousands of steam generator tubes carry radioactive water, and eddy current probes pulled through them are the main way to check them; plants must repair or plug any tube with damage deeper than 40% of its wall. In December 1996 the NRC wrote that eddy current methods had had "only limited success" in measuring the depth of damage, especially intergranular attack and stress corrosion cracking, and that several utilities were leaving damaged tubes in service on such depth estimates. It proposed requiring plants to show that each sizing technique was qualified for the kind of damage it measured, using, where practical, tubes removed from operating steam generators.

    LessonA method that reliably finds damage may still not reliably measure how deep it goes.

    govinfo.gov

    Credit

    the US Nuclear Regulatory Commission

  5. 2009

    Wall loss through insulation

    Pulsed eddy current testing sends pulses of magnetic field through insulation into a steel pipe and estimates the average wall thickness over a patch about 45 to 300 mm across, so pipes can be screened for corrosion without stripping the insulation. Colin Brett and Jan de Raad reported validating such a system for measuring wall thinning through insulation in 1996. In 2009 EPRI, the US power industry's research institute, checked the RTD-INCOTEST system of Röntgen Technische Dienst on insulated pipe elbows at a power plant running at 149 to 157 °C, against ultrasonic readings taken with the insulation removed. On the plant's elbows its minimum-wall readings came within 9% of the ultrasonic readings. On EPRI's mock-up its readings came within 7% of the averaged ultrasonic thickness, and within 3% in a mode meant for local wall loss. A crew examined about eight components in an eight-hour shift. EPRI called it an effective screening tool, not a way to find small local flaws.

    api.crossref.orgrestservice.epri.com

    Credit

    Röntgen Technische Dienst (RTD); evaluated by EPRI

Watch for

  1. Checking metal as it prints

    Wire arc additive manufacturing builds large metal parts from weld beads laid layer on layer, and it can leave weld-like flaws. A team at the University of Strathclyde mounted a phased array ultrasonic probe and an eddy current array on an industrial robot arm with force control, so that each layer is scanned during the build without changing tools. On two titanium alloy (Ti-6Al-4V) blocks with planted flaws, combining the two kinds of data raised the contrast between flaw and background by 4.44 dB and 9.02 dB, and the method also found tungsten inclusions in a printed titanium sample.

    Achieved whenthe system is used on production builds and an outside party confirms the flaws it flags, and those it misses, by CT scanning or cutting.

    strathprints.strath.ac.uk

    Claimed by

    Vedran Tunukovic and ten co-authors, University of Strathclyde, in NDT & E International, published online February 2026

  2. Arrays built for robot cells

    Eddyfi Technologies launched Ignite, an eddy current array instrument with 64, 128 or 256 channels, designed for fixed stations, robotic cells and crawlers, at the ASNT 2026 conference on 12 October 2026. Its announced uses include turbine disks and blades, rotating parts, composite-wrapped pressure vessels and welds; first commercial deliveries were scheduled for December 2026, and no customer results were reported.

    Achieved whena manufacturer reports routine use in a robotic cell, with miss and false-call rates compared with its earlier manual method.

    inspenet.com

    Claimed by

    Eddyfi Technologies, October 2026

Open

  1. 01

    Chiller tubes, cut and measured

    An open set of eddy current recordings from heat exchanger tubes taken out of retired water chillers and condensers, scanned with a bobbin probe, a coil pulled through the tube, and then cut open at every signal so the true depth of each pit, crack or wear mark is measured. Add a script that scores depth calls by people or by software.

    The brief
    Credit · unclaimed
  2. 02

    A crack pen under $50

    An open-hardware eddy current pen for finding surface cracks, built around an inductance-to-digital converter, a chip that turns a coil's response to nearby metal into numbers, with a phone app. Test it blind against a commercial eddy current flaw detector on reference blocks with machined notches and on parts with real fatigue cracks.

    The brief
    Credit · unclaimed

Open 01 · the brief

Chiller tubes, cut and measured

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open set of eddy current recordings from heat exchanger tubes taken out of retired water chillers and condensers, scanned with a bobbin probe, a coil pulled through the tube, and then cut open at every signal so the true depth of each pit, crack or wear mark is measured. Add a script that scores depth calls by people or by software.

Why it is still open

The NRC wrote in 1996 that eddy current had had "only limited success" in measuring flaw depth in steam generator tubes, and that qualification should rest, where practical, on tubes removed from service. Outside nuclear plants, Eddyfi Technologies says most assisted-analysis tools were built for steam generator tubes, that problems such as uneven pulling speed and missing tube maps are common, and that it has built its own AI tool. Tikesh Kumar Sahu and two co-authors trained a random-forest model to find flaws in heat exchanger tube data (Journal of Nondestructive Evaluation, July 2025). The open MDDECT set (Meng and colleagues, 2021) holds 48,000 eddy current scans of 18 defects 0.3 to 2.0 mm deep, but in a flat stainless steel sheet, not in tubes. Searches of Zenodo, Hugging Face and the web in November 2026 found no public bobbin-probe recordings paired with measured depths.

govinfo.govbindt.orgapi.crossref.orgarxiv.org

Built with what exists

Tube bundles from chillers that HVAC contractors replace, collected after the contractor has recovered the refrigerant; a commercial tube eddy current instrument and bobbin probes, rented with a Level 2 tube analyst; a calibration tube with drilled holes and grooves of known depth; a stereo microscope and a depth gauge for the cut tubes; Python for the scoring script.

  1. First step

    Ask an HVAC contractor to set aside the condenser bundle from one chiller it is replacing, and scan 20 of its tubes with a hired analyst.

  2. Done looks like

    200 tubes and at least 500 signals, each with a measured depth, released under an open license, with the depth errors of two human analysts and at least one model published for the same signals.

Open 02 · the brief

A crack pen under $50

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open-hardware eddy current pen for finding surface cracks, built around an inductance-to-digital converter, a chip that turns a coil's response to nearby metal into numbers, with a phone app. Test it blind against a commercial eddy current flaw detector on reference blocks with machined notches and on parts with real fatigue cracks.

Why it is still open

Researchers have built eddy current sensors on these chips to find defects in carbon fiber (Ma and colleagues, Sensors, 2024) and corrosion of steel bars inside concrete (Thibbotuwa and colleagues, Sensors, 2024), and tested them in their own labs. Open designs exist too: 3D printer owners build eddy current probes on TI's LDC1612 chip to map the height of a print bed, such as the open-source LDC1612-EDDY board, and circuit files for an ESP32-based eddy current flaw detector were posted on GitHub in November 2025 with no license and no test results. A Europe PMC search in November 2026 found no blind comparison of such a sensor with a commercial instrument on standard notch blocks.

ebi.ac.ukebi.ac.ukgithub.comgithub.com

Built with what exists

An inductance-to-digital converter from Texas Instruments' LDC series, on its evaluation board at first; a microcontroller board with Bluetooth, such as an ESP32; a small wound or printed coil in a 3D-printed pen housing; aluminum and steel reference blocks with machined notches 0.2, 0.5 and 1.0 mm deep from an NDT supplier; a commercial instrument and a Level 2 operator for the comparison.

  1. First step

    Buy an inductance-to-digital converter evaluation module and an aluminum notch block, and log the reading as the coil crosses the 0.5 mm notch.

  2. Done looks like

    200 blind trials on each block, notched and plain spots in random order, with detection rates and false calls for the pen and for the commercial instrument, and the design files, firmware and a parts list under $50 released.