BRENNEN

Industries / Technology / Lasers and photonics

Medical lasers

Medical lasers is the work of designing, testing and getting approval for the lasers doctors use to seal and reshape the eye, break up kidney stones and cut tissue, and of the safety rules that every laser product must meet.

7

Milestones achieved, from 1949 to 2022.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1949

    Sunlight seals the retina

    Gerhard Meyer-Schwickerath in Germany showed that burns made with focused light could treat patients whose retina was coming loose; he started with sunlight in 1949, then moved to carbon and xenon arc lamps. The lamps burned a lot of the tissue around the target and were awkward to aim. A laser gives one color in a narrow beam, and eye doctors took it up within a year of its invention: M. M. Zaret and colleagues reported eye lesions made by a ruby laser in Science in 1961, the ruby laser became the first commercial eye laser, and a blue-green argon laser followed in 1964, by the account of the American Society of Retina Specialists.

    retinahistory.asrs.org

    Credit

    Gerhard Meyer-Schwickerath; M. M. Zaret and colleagues

  2. 1976

    Scatter burns halve vision loss

    In proliferative diabetic retinopathy, fragile new blood vessels grow on the retina and can bleed and blind. The Diabetic Retinopathy Study, a US trial, treated eyes with extensive "scatter" photocoagulation, many small burns spread across the retina, from an argon laser or a xenon lamp, and kept other eyes untreated for comparison. Its first report in 1976 found that treatment prevented severe vision loss over two years, and by 1981 it put the reduction at 50% or more.

    LessonThe two light sources worked about equally well, but harmful effects such as narrowed side vision were more frequent and more severe with the xenon lamp.

    ebi.ac.ukebi.ac.uk

    Credit

    The Diabetic Retinopathy Study Research Group

  3. 1976

    A class for every laser

    The US rule for laser products, 21 CFR 1040.10, applies to every laser product made or assembled after 1 August 1976. It sorts products into classes by the most light a person can reach during use, from Class I, "not considered to be hazardous", to Class IV, "an acute hazard to the skin and eyes from direct and scattered radiation", and sets safety features such as a removable key for Class IIIb and IV systems. In February 2023 the FDA's Laser Notice 56 said it would not enforce parts of its own rule against makers that meet the matching clauses of the international standards IEC 60825-1 Edition 3 and, for medical lasers, IEC 60601-2-22 Edition 3.1.

    law.cornell.edufda.gov

    Credit

    US Food and Drug Administration

  4. 1995

    Excimer lasers reshape corneas

    An excimer laser makes pulses of far-ultraviolet light. In 1983 S. L. Trokel, R. Srinivasan and B. Braren reported that such pulses removed tissue from cow corneas by breaking molecular bonds rather than by heating: 1 joule per square centimeter took off 1 micrometer, with no heat damage beside the cut. On 20 October 1995 the FDA approved the SVS Apex excimer laser for photorefractive keratectomy (PRK), which reshapes the surface of the cornea to correct 1.5 to 7.0 diopters of short sight in adults aged 21 or over.

    ebi.ac.ukaccessdata.fda.govebi.ac.uk

    Credit

    S. L. Trokel, R. Srinivasan and B. Braren; Summit Technology, maker of the Apex

  5. 2019

    Laser before eye drops

    Selective laser trabeculoplasty (SLT) uses short pulses from a Q-switched Nd:YAG laser on the eye's drainage tissue to lower the pressure that damages the optic nerve in glaucoma. The LiGHT trial at Moorfields Eye Hospital and University College London gave 718 newly diagnosed patients either SLT or eye drops first. After three years, 74.2% of the SLT group needed no drops to stay at their target pressure, 11 patients in the drops group needed glaucoma surgery against none in the SLT group, and SLT first had a 97% probability of being the more cost-effective choice. In January 2022 NICE, which sets treatment guidance in England, told doctors to offer SLT as the first treatment to people newly diagnosed with glaucoma that is not advanced, and to many with raised eye pressure.

    ebi.ac.uknice.org.ukoptics.org

    Credit

    Gus Gazzard and the LiGHT Trial Study Group

  6. 2020

    A pricier laser adds nothing

    In femtosecond laser-assisted cataract surgery, a laser with pulses measured in femtoseconds, millionths of a billionth of a second, makes the cuts and breaks up the clouded lens before the usual ultrasound probe removes it. The FEMCAT trial in five French university hospitals randomized 907 patients (1,476 eyes) between the laser and standard surgery. Success at three months was 41.1% with the laser and 43.6% without, no significant difference, and standard surgery saved €10,703 for each extra successful patient. A UK trial, FACT, reported the same year that the laser was no worse than standard surgery.

    LessonA laser step that is more precise did not by itself give patients better results.

    ebi.ac.ukebi.ac.uk

    Credit

    C. Schweitzer and the FEMCAT study group, University of Bordeaux

  7. 2022

    Fiber lasers clear more stones

    Doctors break up kidney stones through a thin scope with a laser fiber; the holmium:YAG laser was the standard one. A thulium fiber laser makes its light inside a long optical fiber instead of a crystal. At Haukeland University Hospital in Bergen, Norway, 120 patients were randomized between the two: after one session 92% were stone-free with the thulium fiber laser against 67% with holmium, and bleeding that blocked the view fell from 22% of patients to 5%.

    LessonMore power is not always better. On 15 August 2021 the FDA had issued a Class II recall of Olympus's Soltive thulium fiber lasers after thermal injury when a user went past the standard 20 W power presets, and a 2026 trial at the same hospital found that 16 to 18 W did not shorten operations and left fewer patients completely stone-free (44% against 63%) than 4 to 6 W.

    ebi.ac.ukebi.ac.ukpmc.ncbi.nlm.nih.govebi.ac.uk

    Credit

    Ø. Ulvik and colleagues, Haukeland University Hospital

Watch for

  1. Incision-free glaucoma channels

    ViaLase says its femtosecond laser, guided by optical coherence tomography (an imaging method that uses near-infrared light), cuts a drainage channel about 500 by 200 micrometers through the eye's Schlemm's canal without any incision, and that this could control pressure for longer than SLT. It treated the first patient in a randomized US trial against SLT in December 2025; the laser has carried a CE mark for some European markets since August 2024.

    Achieved whenthe randomized trial's results are published and the FDA clears or approves the device.

    optics.org

    Claimed by

    ViaLase, December 2025

  2. Firing only at stones

    IPG Medical's StoneSense lets its thulium fiber laser fire only when the fiber tip is close to a stone. In a University of Kansas laboratory test on stone-like blocks, published in October 2026, the prototype fired only within about 2.3 to 2.7 mm of the stone, used 18% less energy and warmed the fluid by 4.2 °C instead of 5.1 °C, but took longer per case.

    Achieved whena trial in patients confirms the same benefits and the system is cleared and sold.

    ebi.ac.uk

    Claimed by

    IPG Medical; tested in vitro by M. E. Thoman, W. R. Molina and colleagues, October 2026

Open

  1. 01

    One table of stone heating

    An open table of every published measurement of how much the fluid around a stone heats up during laser treatment, in test tubes, model kidneys and animals, with the laser power, pulse settings, irrigation flow, fluid volume and fiber size beside each temperature curve; then a test of the two published heating models against all of it, and a check of laser makers' published power presets against the result.

    The brief
    Credit · unclaimed
  2. 02

    A tested laser-class calculator

    An open-source program that assigns a laser product its class and computes the maximum permissible exposure (MPE, the most light an eye or skin can take without injury) and the nominal ocular hazard distance (how far away the beam stays dangerous to eyes) under IEC 60825-1 and ANSI Z136.1, shipped with a public set of test cases whose answers come from published worked examples.

    The brief
    Credit · unclaimed

Open 01 · the brief

One table of stone heating

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open table of every published measurement of how much the fluid around a stone heats up during laser treatment, in test tubes, model kidneys and animals, with the laser power, pulse settings, irrigation flow, fluid volume and fiber size beside each temperature curve; then a test of the two published heating models against all of it, and a check of laser makers' published power presets against the result.

Why it is still open

Each published model was checked against its own laboratory's experiments: J. G. Williams and colleagues (2021) "with matched in vitro experiments", and A. D. Maxwell and colleagues (2019) against "previous in vitro temperature data in a test tube". A 2026 systematic review of 19 studies found that the injury threshold most of them use, 120 cumulative minutes at 43 °C, "has not been empirically validated for renal tissue", and that kidney damage may start at 20 to 70 minutes. Searches of Europe PMC on 20 November 2026 found many single-laboratory temperature studies and reviews, but no pooled public dataset.

ebi.ac.ukebi.ac.ukebi.ac.ukebi.ac.uk

Built with what exists

The Europe PMC search interface to find the studies; WebPlotDigitizer to read curves off published figures; Python with NumPy and SciPy; the Sapareto and Dewey thermal-dose formula that the 2026 review says all 19 studies used; a Claude-based document reviewer to pull laser settings out of methods sections for a person to check (see the Note "Seven more flagged").

  1. First step

    Pull the laboratory and animal temperature studies of 2018 to 2026 from Europe PMC and digitize the validation figures of the Williams and Maxwell papers.

  2. Done looks like

    At least 30 studies and 300 pairs of settings and measured temperature rise, each cited to a figure or table; each model's error in °C reported for every study; a second person re-reads a random 10% of curves and agrees within 1 °C; and every published preset of at least five stone lasers scored against the limits of 10 W in the ureter and 20 W in the kidney that a 2025 review by the European Association of Urology's endourology section supports.

Open 02 · the brief

A tested laser-class calculator

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open-source program that assigns a laser product its class and computes the maximum permissible exposure (MPE, the most light an eye or skin can take without injury) and the nominal ocular hazard distance (how far away the beam stays dangerous to eyes) under IEC 60825-1 and ANSI Z136.1, shipped with a public set of test cases whose answers come from published worked examples.

Why it is still open

A GitHub search on 20 November 2026 found four open laser-safety calculators, and none shows a test suite in its file listing: M-Tekin's IEC 60825-1 calculator holds two code files after two commits, SWC-Advanced-Microscopy's is one MATLAB live script for Class 3B lasers, and the other two are a single-commit app and a tool for one insect-control laser. Further searches for "laser MPE" and "Z136" found a one-page web calculator, a single index.html after two commits, and scripts that redraw the standard's figures, again with no tests. Makers classifying a product must meet the FDA rule or the IEC clauses the FDA accepts in Laser Notice 56.

github.comgithub.comgithub.comgithub.comgithub.comfda.gov

Built with what exists

Python and pytest; bought copies of the current IEC 60825-1 and ANSI Z136.1; the class definitions in 21 CFR 1040.10; a coding agent that writes code against the tests (see the Note "Code no person read", on a cloud emulator AWS says agents wrote and that was checked only by tests).

  1. First step

    Code the Class 1 emission limits for continuous visible lasers and write 10 test cases from worked examples in published laser-safety papers.

  2. Done looks like

    At least 100 test cases, each traced to a published source, all passing; a certified laser safety officer reviews 20 cases and finds no errors; and results match one commercial calculator within 1% on 50 random cases.