Ventilation and controls is the work of stopping a contaminant before it reaches a worker's breath, in the order hygienists rank the options: remove the material, enclose it or extract it at the source with hoods and fans, and only as a last resort fit the worker with a respirator.

6

Milestones achieved, from 1930 to 2024.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1930

    Dry drilling at Hawks Nest

    From spring 1930 nearly 3,000 men drove a 3-mile (about 5 km) tunnel for Union Carbide through Gauley Mountain, West Virginia, in sandstone that one account puts at 90 to 97% silica. To save time the contractor, Rinehart and Dennis, drilled mostly dry, although wet drilling, ventilation and masks were known ways to keep the dust down. Congressional testimony in 1936 put the deaths from silicosis at up to 300; Martin Cherniack, who wrote a 1986 book on the tunnel, estimates at least 764.

    LessonKnown controls protected no one, because the job counted as construction rather than mining, so mine safety rules did not apply, and the contract paid a bonus for finishing early.

    npr.orgheinonline.com

    Credit

    investigated by the US House Committee on Labor in 1936

  2. 1951

    A design manual for ventilation

    ACGIH first published Industrial Ventilation: A Manual of Recommended Practice, a reference for designing the hoods, ducts and fans that pull contaminants away at the source. It is now in its 28th edition, as the Design Manual, with a companion manual on operation and maintenance.

    acgih.org

    Credit

    ACGIH's Industrial Ventilation Committee

  3. 1988

    Extraction tested every 14 months

    Britain's Control of Substances Hazardous to Health (COSHH) Regulations 1988 required employers to have local exhaust ventilation (LEV), the hoods and ducts that extract dust or fume at the source, thoroughly examined and tested at least once every 14 months, and to keep the records for at least 5 years. The 2002 regulations kept the rule, and HSE's guide HSG258, in its third edition since 2017, sets out how the examination is done.

    legislation.gov.ukhse.gov.uk

    Credit

    the UK Health and Safety Executive

  4. 1995

    Nine classes of respirator filter

    A NIOSH rule of 8 June 1995, in force from 10 July, replaced respirator classes named for dust, fume and mist with nine filter classes: N (not for oil mists), R and P (for oil mists), each at 95%, 99% or 99.97% efficiency. Filters are now tested with particles of about 0.3 µm, the size that gets through most easily, using salt or an oily test aerosol, so a filter's class holds whatever the dust. The N95 class comes from this rule.

    govinfo.govlaw.cornell.edu

    Credit

    NIOSH

  5. 1998

    A fit test every year

    OSHA's respiratory protection standard of 8 January 1998 requires a written respirator program, and requires anyone who wears a tight-fitting respirator to pass a fit test before first use, with any new model or size, and at least once a year. In a quantitative fit test an instrument measures how much test aerosol leaks in; a half mask passes at a fit factor of 100, meaning the air outside holds 100 times the concentration inside, and a full facepiece at 500.

    osha.gov

    Credit

    OSHA

  6. 2024

    Australia bans engineered stone

    Engineered stone, used for kitchen benchtops, is crushed stone, mostly quartz, bound with resin, and can be more than 90% crystalline silica, against 10 to 45% for granite (figures from an OSHA and NIOSH hazard alert, as reported by AIHA). After silicosis rose among the workers who cut and fit it, Australia's work health and safety ministers agreed on 13 December 2023, on the advice of Safe Work Australia, to ban its manufacture, supply, processing and installation from 1 July 2024. AIHA and Dezeen report it as the first country to do so.

    LessonRemoving the material, the first step in the ranking of controls, protects workers whether or not anyone switches on the extraction.

    aiha.orgdezeen.com

    Credit

    Australia's federal, state and territory work health and safety ministers, advised by Safe Work Australia

Watch for

  1. Stone with almost no silica

    Caesarstone began a US rollout of its ICON surfaces in May 2025 and announced the line in July, saying they contain less than 1% crystalline silica and about 80% recycled material; it moved 19 existing quartz products to the new formula. The company still advises fabricators to use safety measures. Australia's ban decision stated that there is no scientific evidence that lower-silica engineered stone is safer to work with.

    Achieved whena regulator or university publishes air samples taken while workers cut and polish the new slabs, showing respirable crystalline silica well under the 0.05 mg/m³ limit and naming the other dusts released.

    stoneworld.comaiha.org

    Claimed by

    Caesarstone, July 2025

  2. Breath sensors check the seal

    Engineers at the Universidad de Concepción, Chile, fitted a small sensor module inside a reusable industrial respirator that measures pressure, temperature and humidity with each breath and sends the readings to a phone. Trained on more than 10,000 breathing cycles from 20 volunteers, in fit and misfit conditions labeled with OSHA's qualitative fit test, their best models scored F1 values (a combined measure of missed and false alarms) near or above 95%. Today's fit tests are periodic and cannot catch a seal that slips during a shift.

    Achieved whenan independent group tests the system on workers during real shifts and compares its alarms with fit factors measured by a quantitative instrument.

    pmc.ncbi.nlm.nih.gov

    Claimed by

    P. Aqueveque and colleagues, Universidad de Concepción, November 2025

Open

  1. 01

    Judge smoke tests by camera

    A program that watches a video of a smoke test at an extraction hood and says whether the smoke was captured, escaped, or drifted toward a manikin's breathing zone, with a short clip showing where it escaped.

    The brief
    Credit · unclaimed
  2. 02

    Check ventilation reports for gaps

    A checker that reads an LEV thorough examination and test report, the report British law requires at least every 14 months, and lists what is missing from the contents HSE's guide sets out, plus any reading that falls below the report's own benchmark.

    The brief
    Credit · unclaimed

Open 01 · the brief

Judge smoke tests by camera

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A program that watches a video of a smoke test at an extraction hood and says whether the smoke was captured, escaped, or drifted toward a manikin's breathing zone, with a short clip showing where it escaped.

Why it is still open

HSE's LEV guide, HSG258, has the examiner watch smoke and dust-lamp tests, by eye or camera, and judge leakage, eddying and smoke reaching the breathing zone; the result is a judgment, not a number. The nearest automated work found is a 2014 US patent application that scores kitchen range-hood capture from shadow images, and research datasets of smoke from chimneys; searches of papers and GitHub found no tool or dataset for industrial hood smoke tests.

hse.gov.ukpatents.justia.com

Built with what exists

A benchtop fume extractor or small capturing hood with a variable-speed fan; a smoke generator that uses glycol fluid, sold for ventilation testing; a hot-wire anemometer; a phone camera and a dust lamp (a bright, parallel beam that makes fine particles visible); a video segmentation model such as Meta's SAM 2 to outline the smoke; a fixed-answer classifier for the captured or escaped call (Notes: "A thousand questions, one pass").

  1. First step

    Build the bench with one hood, away from any smoke detector, film 30 smoke tests at three fan speeds, and ask one qualified LEV examiner to label them.

  2. Done looks like

    200 filmed tests at set fan speeds, distances and cross-drafts, each also judged by three LEV examiners, with the program agreeing with the examiners' majority on at least 90% of tests and the videos and labels published.

Open 02 · the brief

Check ventilation reports for gaps

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A checker that reads an LEV thorough examination and test report, the report British law requires at least every 14 months, and lists what is missing from the contents HSE's guide sets out, plus any reading that falls below the report's own benchmark.

Why it is still open

HSG258 lists what each report should hold, from the date of the last test to a diagram with the test points, and the Institute of Local Exhaust Ventilation Engineers (ILEVE) publishes a report template. The reports themselves are free-form PDFs, and some are public in UK council environmental-permit files: a July 2025 report in Knowsley's records a duct at 9.8 m/s against its own benchmark of 10 m/s. The one open-source tool found, an Office add-in posted on GitHub in 2026, inserts standard HSG258 recommendation text into reports; it does not check them. No study of report completeness was found.

hse.gov.ukcibse.orgknowsley.gov.ukgithub.com

Built with what exists

Public reports from UK council permit registers; the ILEVE template; the report section of HSG258 (paragraph 349); a document-reading AI model that accepts PDFs, such as Claude; a table extractor such as pdfplumber (Notes: "Seven more flagged", "The jobs agents repeat").

  1. First step

    Collect 20 public LEV reports from council permit registers and turn HSG258 paragraph 349 and the ILEVE template into a checklist.

  2. Done looks like

    50 public reports checked, with the program's list of missing items and failed readings matching an independent check by a qualified LEV examiner on at least 90% of items, and every miss and false flag published.