BRENNEN

Industries / Industrial equipment and services / Industrial services / Industrial hygiene

Chemicals and skin

This is the work of finding and controlling chemicals that harm workers through the skin, or after the body has taken them up, and of choosing gloves and safer substitutes.

7

Milestones achieved, from 1775 to 2026.

1

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1775

    Soot cancer in sweeps

    The London surgeon Percivall Pott described a cancer of the scrotum in chimney sweeps, who often climbed chimneys as small boys, and blamed soot lodged in the folds of the skin. A 2024 review in Cureus calls it the first known report of a job causing cancer. The advice that followed was regular washing and clean clothes, and Britain's Chimney Sweepers Act of 1788 required masters to wash their boys at least once a week.

    LessonWhat stays on the skin can do as much harm as what is breathed in.

    pmc.ncbi.nlm.nih.gov

    Credit

    Percivall Pott

  2. 1981

    Iron sulfate tames cement eczema

    Wet cement holds traces of hexavalent chromate, a chromium compound that makes skin allergic, and cement eczema was once a common work disease of builders. Fregert, Gruvberger and Sandahl reported in 1979 that adding 0.35% by weight of iron sulfate to cement turns the chromate into a form that does not cause the allergy, and Denmark has added it to all its cement since 1981, keeping soluble chromate below 2 mg per kg. An EU directive of 2003 banned cement with more than 2 ppm of soluble chromate, applied in the UK from January 2005. Stocks and colleagues counted UK cases reported by dermatologists and found that allergic skin disease blamed on chromate fell by about half (an incidence rate ratio of 0.48) between 2002 to 2004 and 2005 to 2009.

    ebi.ac.ukebi.ac.ukebi.ac.uk

    Credit

    Fregert, Gruvberger and Sandahl; Denmark; EU Directive 2003/53/EC

  3. 1981

    A standard test for gloves

    ASTM F739, first issued in 1981, set a laboratory method for timing how long a liquid or gas takes to pass through a piece of glove or suit material at the molecular level. That process, called permeation, can happen with no visible change in the glove. The test reports a breakthrough time, the time until the chemical passes through at 0.1 µg per square centimetre per minute, and a permeation rate, and these are the figures that glove makers such as Ansell print in their charts.

    pmc.ncbi.nlm.nih.govastm.org

    Credit

    ASTM International's committee F23, building on work by Nelson and colleagues

  4. 1986

    Cameras measure skin deposits

    Fenske, Leffingwell, Wong and Spear described a way to measure what lands on the skin. A fluorescent whitening agent is mixed into a pesticide spray, workers are viewed under ultraviolet light afterwards, and a television camera linked to a microcomputer measures the glow, down to 100 nanograms per square centimetre. In their tests the tracer and the pesticide malathion landed in step (correlation 0.985 under controlled spraying, 0.942 in the field). A British version, the Health and Safety Laboratory's FIVES system, estimated doses on skin to within plus or minus 70% of known amounts in 1997 tests.

    ebi.ac.ukebi.ac.uk

    Credit

    Fenske, Leffingwell, Wong and Spear; M. W. Roff for FIVES

  5. 1996

    A substitute solvent harms workers

    Workers at a Korean electronics company were reported in 1996 with reproductive and blood disorders after the company replaced chlorofluorocarbons, solvents that damage the ozone layer, with a solvent containing 2-bromopropane. In 1998 rat tests by Gaku Ichihara's group showed that its close relative 1-bromopropane, sold as another ozone-safe substitute, was more toxic to nerves. A New Jersey neurologist reported the first human case of 1-bromopropane nerve damage in 1999, and cases followed in North Carolina, Utah, Pennsylvania, Taiwan, Japan and New Jersey, where dry cleaners had switched to it from perchloroethylene.

    LessonA replacement chemical needs its own toxicity tests before it is put into use.

    pmc.ncbi.nlm.nih.gov

    Credit

    Gaku Ichihara and colleagues

  6. 1997

    Gloves that let poison through

    In 1996 Karen Wetterhahn, a chemistry professor at Dartmouth College, spilled one to several drops of dimethylmercury, a liquid mercury compound then used to calibrate laboratory instruments, on the back of her latex-gloved hand while working in a fume hood. She died of mercury poisoning in June 1997. An independent laboratory then found that the chemical passes through latex, PVC and neoprene gloves almost at once. OSHA's 1998 bulletin said that only a laminate glove (Silver Shield) had held it back for at least 4 hours, and warned that safety data sheets may not give adequate guidance on gloves.

    LessonA glove protects only against the chemicals it has been tested against.

    osha.govsites.dartmouth.edu

    Credit

    OSHA's Boston Regional Office, which investigated the death

  7. 2026

    EU law adds skin warnings

    Directive (EU) 2026/2450, signed on 21 October 2026, sets binding air limits for cobalt compounds, mixtures of polycyclic aromatic hydrocarbons (PAHs, measured as benzo[a]pyrene), isoprene and 1,4-dioxane. It marks the PAH mixtures and 1,4-dioxane "skin", a note that they pass through skin, and marks cobalt as a cause of skin and lung allergy. It also sets a binding limit for 1,4-dioxane in urine: 45 mg of its breakdown product HEAA per gram of creatinine at the end of a shift. EU countries must apply it by 20 November 2028.

    publications.europa.eu

    Credit

    the European Commission, Parliament and Council

Watch for

  1. Glove data for 20,000 chemicals

    uvex says its Glove Expert gives permeation data and breakthrough times by glove material from an online database, with a glove-plan tool covering more than 20,000 chemicals, and that its glove centre in Germany will test chemicals that are not listed. The article does not say how many entries come from laboratory tests and how many are estimated.

    Achieved whenuvex publishes which entries were measured and to which standard, and an outside laboratory's retest of a sample of entries agrees with them.

    hsmsearch.com

    Claimed by

    uvex, in an article by its head of marketing, May 2026

Open

  1. 01

    One table for glove tests

    A free, machine-readable table of the permeation results that glove makers publish, one row per test: chemical and its CAS number, maker, glove model, material, thickness, test standard, breakthrough time, permeation rate, and the page it came from. Then use the table to check the glove advice in section 8 of safety data sheets, the documents that travel with every chemical product.

    The brief
    Credit · unclaimed
  2. 02

    Measure glove contamination by phone

    A phone-camera method that measures how much of a harmless fluorescent tracer lands on gloves and sleeves during simulated tasks, such as pouring a liquid or handling wet parts, reported in micrograms per square centimetre and checked against the amount washed off and measured in a fluorometer.

    The brief
    Credit · unclaimed

Open 01 · the brief

One table for glove tests

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A free, machine-readable table of the permeation results that glove makers publish, one row per test: chemical and its CAS number, maker, glove model, material, thickness, test standard, breakthrough time, permeation rate, and the page it came from. Then use the table to check the glove advice in section 8 of safety data sheets, the documents that travel with every chemical product.

Why it is still open

Each maker publishes its own charts or its own selection tool, such as Ansell's resistance guide and uvex's Glove Expert. A 2019 review notes that results for the same chemical and the same nominal glove material can differ between makers, and that the test standards in use (ASTM F739, EN 374 and ISO 6529) can give different breakthrough times for the same material. The free ProtecPo tool from France's INRS predicts resistance from solubility theory, not test results, and says its picks should be confirmed by tests. Searches of GitHub and the literature found no open table that combines makers' results.

pmc.ncbi.nlm.nih.govprotecpo.inrs.fr

Built with what exists

Makers' public PDF charts, such as Ansell's 8th edition permeation guide; a general AI model that copies each table row with its page number, with a person checking a sample (Notes: "The jobs agents repeat"); Python and pandas; a CSV file on GitHub.

  1. First step

    Download five makers' charts and copy by hand the rows for ten common solvents, such as acetone, toluene and methanol, to settle the table's columns.

    safety.duke.edu

  2. Done looks like

    At least 3,000 rows from at least five makers, every row linked to its page; a published count of chemical and material pairs where one maker reports breakthrough under 10 minutes and another over 60 minutes for gloves of similar thickness; and, for 200 public safety data sheets for common solvents, the share that name a glove material and a breakthrough time, and the share whose named material the makers' own data rate poorly.

Open 02 · the brief

Measure glove contamination by phone

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A phone-camera method that measures how much of a harmless fluorescent tracer lands on gloves and sleeves during simulated tasks, such as pouring a liquid or handling wet parts, reported in micrograms per square centimetre and checked against the amount washed off and measured in a fluorometer.

Why it is still open

OSHA says measuring what lands on the skin is not a simple or routine procedure and is still limited to research and specially designed studies. A large European test reported in 2020, the SysDEA project (TNO, the Benaki Phytopathological Institute and BAuA), photographed volunteers in a purpose-built ultraviolet room. Its fluorescence method worked for spraying (correlation above 0.77) but correlated poorly for pouring and for handling wet or dusty objects (−0.17 to 0.28), and it excluded hands. A search found no phone-based method checked against wash-off measurements.

osha.govpublications.tno.nl

Built with what exists

A phone that saves raw images; a 365 nm ultraviolet torch, with UV-blocking glasses, and a dark box; riboflavin (vitamin B2), which glows under ultraviolet light, as the tracer; nitrile gloves on mannequin hands, so that nobody is exposed; OpenCV image software; a low-cost fluorometer for the wash-off reference.

  1. First step

    Pipette known amounts of riboflavin solution onto glove squares, photograph them in a dark box under the torch, and plot pixel brightness against dose.

  2. Done looks like

    On 100 glove squares dosed by pipette with known amounts from 1 to 100 µg/cm², the phone estimate within 30% of the applied amount for at least 90; then 20 filmed pouring and handling tasks on mannequin hands, each with the phone estimate and the wash-off result side by side; images, code and results published.