BRENNEN

Industries / Industrial equipment and services / Industrial machinery / Industrial filtration

Filter materials

Filter materials are the papers, felts, fibers and membranes that do the catching inside a filter, together with the tests that grade them.

6

Milestones achieved, from 1942 to 2020.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1942

    HEPA grows from gas masks

    By Camfil's account, British forces used a pleated cellulose-asbestos paper known as the "Absolute" filter in blower units for places where gas masks were impractical. When the Manhattan Project began in August 1942, the US Army Chemical Corps started a secret project to build on it and filter radioactive particles, and the Nobel laureate Irving Langmuir helped set 0.3 micron particles as the size that mattered most. The name HEPA, for high-efficiency particulate air, came into use in the 1950s, when the design was declassified. Today a HEPA filter for a US nuclear site must let through no more than 0.03% of 0.3 micron test particles, which means catching 99.97%.

    camfil.comosti.gov

    Credit

    US Army Chemical Corps, with Irving Langmuir

  2. 1954

    Fibers blown from melted plastic

    Van A. Wente, C. D. Boone and E. L. Fluharty of the US Naval Research Laboratory described how to make "superfine" fibers in NRL Report 4364 of 25 May 1954. In the process, now called meltblowing, melted plastic is pushed through a row of small holes and drawn out into fibers by jets of hot air, which land on a moving screen as a tangled web. Robert Buntin and Dwight Lohkamp described it in 1973 as "a one-step process for new non-woven products", and a 3M patent of 1988 for respirators made from blown fibers cites both papers. Meltblown fabric is now a key layer in face masks and respirators.

    trea.comnonwovens-industry.com

    Credit

    Van A. Wente and colleagues, Naval Research Laboratory; Robert A. Buntin and Dwight D. Lohkamp

  3. 1998

    EPA tests bag media

    The US EPA's technology verification program, started in 1995, wrote a laboratory test that runs cleanable filter media through pulse-jet cycles and measures how much fine dust, PM2.5 (particles under 2.5 microns), gets through, so buyers could see independent numbers. A 2012 paper by Minh Pham, Christina Clark and John D. McKenna says the protocol became the basis of ASTM D6830-02 and ISO 11057, and that California's South Coast air district and EPA's air standards office encourage the use of verified media. The EPA's 1998 cost manual already listed membrane media, a thin film of PTFE (the plastic sold as Teflon) laminated to felt, from Gore, Tetratec and BHA; with pores of about 1 micron, they catch fine dust from the start rather than after a dust cake forms.

    osti.govdoi.orgepa.gov

    Credit

    US EPA's verification program; J. C. Mycock, J. H. Turner and colleagues (1998 paper)

  4. 2004

    Nanofiber layers on filters

    Electrospinning, which draws very fine fibers out of a liquid with electric force, goes back to a British patent filed by John F. Cooley in 1900, but was little used for decades. A 2026 patent history in International Filtration News says Donaldson developed commercial nanofiber-coated filter media in the early 2000s, with patents starting from US 6,673,136 (2004), and that such media are now widespread in ventilation filters, gas turbine air intakes and dust collectors. Donaldson says its Ultra-Web layer, fibers 0.2 to 0.3 microns thick on a cellulose base, has been on its collector filters for more than three decades.

    filtnews.comdonaldson.com

    Credit

    Donaldson Company

  5. 2016

    Filters graded by particle mass

    ISO 16890, adopted in August 2016 and published in 2017 at international and European level, grades ventilation filters by the share of particle mass they catch in three size bands, PM1, PM2.5 and PM10 (0.3 to 1, 2.5 and 10 microns), the same bands air-quality rules use. The European standard it replaced, EN 779, rated most filters at a single average particle size of 0.4 microns. ISO 16890 also measures each filter twice: new, and after 24 hours in isopropanol vapor. Camfil says it replaced EN 779 from 1 July 2018, and that filters with the same EN 779 class can fall into different ISO classes.

    aivc.orgcamfil.com

    Credit

    ISO and the European Committee for Standardization; described by Alain Ginestet for the Air Infiltration and Ventilation Centre

  6. 2020

    One fabric runs short

    In early 2020 meltblown fabric, the filter layer of masks and respirators, ran short worldwide. Fastmarkets reports that a European mask maker paying about 10 euros per kilogram before the pandemic paid 40 euros in the first quarter of 2020, and up to 100 euros in the second, if any could be found; prices fell to about 18 euros by the end of 2020 as new lines started. Smithers, a market research firm, put the world meltblown market at 207,400 tonnes in 2019 and 367,800 tonnes in 2020, and by early 2022 said supply was "significantly higher than demand".

    LessonA thin layer can halt a whole product, and building capacity in a rush left far more than was needed.

    fastmarkets.comnonwovens-industry.com

    Credit

    reported by Fastmarkets and Nonwovens Industry, with figures from Smithers

Watch for

  1. Water repellent without PFAS

    Glass microfiber filter media are usually given a water-repellent treatment, and many such treatments use PFAS, long-lasting fluorinated chemicals now being restricted. Ahlstrom says a new glass microfiber medium for ventilation filters, made in Turin, Italy, has no intentionally added PFAS, keeps durable water repellency, and has up to 20% lower initial pressure drop than standard glass media.

    Achieved whenan independent lab publishes the medium's total fluorine content and its efficiency and pressure drop under a standard test such as ISO 16890 or EN 1822, matching the claim.

    ahlstrom.com

    Claimed by

    Ahlstrom, May 2026

  2. HEPA that survives fire

    Standard HEPA filters are glass-fiber paper in a frame, and fire can destroy them. Lawrence Livermore National Laboratory says its ceramic HEPA program, running for more than 20 years, has developed filters that can survive fire conditions, using methods from traditional HEPA materials to electrospinning and 3D printing, and lists the technical, regulatory and commercial work still needed.

    Achieved whena ceramic HEPA filter is qualified under ASME AG-1, the code for nuclear air-cleaning equipment, passes testing at DOE's Filter Test Facility, and is installed in a DOE facility.

    osti.gov

    Claimed by

    Michael Ross and colleagues, Lawrence Livermore National Laboratory, June 2025

Open

  1. 01

    Fluorine in filter media

    An independent survey of fluorine in commercial filter media, covering glass-fiber HEPA and ventilation media, meltblown, nanofiber-coated media and membrane-laminated bag media, including products sold as made without added PFAS, with the results published by product.

    The brief
    Credit · unclaimed
  2. 02

    PFAS-free bags against ePTFE

    A side-by-side laboratory test of membrane bag media made without PFAS against an ePTFE membrane control, under the standard pulse-jet test for cleanable media, with the raw data published.

    The brief
    Credit · unclaimed

Open 01 · the brief

Fluorine in filter media

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An independent survey of fluorine in commercial filter media, covering glass-fiber HEPA and ventilation media, meltblown, nanofiber-coated media and membrane-laminated bag media, including products sold as made without added PFAS, with the results published by product.

Why it is still open

Makers now sell media they describe as made without added PFAS, and a FILTECH 2026 paper by Clean & Science notes that ePTFE, the expanded PTFE in membrane media, counts as a PFAS. The only independent fluorine survey of filters found is of nine face masks, by Derek Muensterman and colleagues in 2022; an OpenAlex search in November 2026 found none for industrial or ventilation media.

doi.orgfiltech.de

Built with what exists

new filters bought from distributors and cut into samples; total fluorine measured by combustion ion chromatography, which burns a sample and measures the fluorine given off, at a contract environmental lab; a spreadsheet of results with lab reports attached.

  1. First step

    Buy ten filters off the shelf (HEPA panels, high-grade ventilation filters and one membrane filter bag) and get quotes from two labs that offer combustion ion chromatography.

  2. Done looks like

    At least 40 media samples from at least eight makers, each tested twice, including at least ten sold as made without added PFAS, with results, methods and detection limits published.

Open 02 · the brief

PFAS-free bags against ePTFE

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A side-by-side laboratory test of membrane bag media made without PFAS against an ePTFE membrane control, under the standard pulse-jet test for cleanable media, with the raw data published.

Why it is still open

The test method for this comparison exists in ISO 11057 and ASTM D6830, which grew from the EPA's verification protocol, but no published comparison of PFAS-free membrane bag media with ePTFE was found in November 2026. The FILTECH 2026 Clean & Science abstract says alternatives "will be proposed and compared" and gives no data.

doi.orgfiltech.de

Built with what exists

an ISO 11057 or ASTM D6830 test run by a university filtration lab or a commercial test lab, using the test dust the standard names; media samples requested from makers; Python to analyze and plot the results.

  1. First step

    List the membrane media now sold as PFAS-free for dust collectors, ask each maker for a 1 square meter sample, and get a quote for the test from a lab that runs ISO 11057.

  2. Done looks like

    At least three PFAS-free membrane media and one ePTFE control, each tested three times, with outlet PM2.5 concentration, residual pressure drop and time between cleaning pulses reported, and the raw data published.