Industries / Construction and property / Damage restoration
Water extraction and drying
Water extraction and drying is pumping out standing water and then drying the building's materials with dehumidifiers, air movers and heat, guided by humidity and moisture readings.
6
Milestones achieved, from 1972 to 2026.
2
To watch for: announced, not yet confirmed outside.
3
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1972
Drying moves on site
After the flash flood of 9 June 1972 in Rapid City, South Dakota, which killed 238 people, Lloyd Weaver, doing unpaid cleanup work in his hometown, began drying carpets and building materials inside people's homes instead of hauling carpets to a cleaning plant. Cleaning & Restoration, the magazine of the Restoration Industry Association (RIA), credits him with "the first specialty designed Porta Dryer for on-location wet carpet drying", and says his seminars from the mid-1970s drew carpet cleaners into insurance water-damage work.
Credit
Lloyd Weaver
1980s
Desiccant drying on a trailer
Claude Blackburn, a carpet cleaner in Skagit County, Washington, opened Dri-Eaz Products in his basement in 1981; its first product was a foam block for lifting furniture off wet carpet. In the mid-1980s Dri-Eaz built the Dri-Eaz 750, a trailer-mounted desiccant dehumidifier, which dries air by passing it over a water-absorbing material. RIA's magazine says the first unit sold for $25,000, and that Blackburn's seminars, priced under $100, sold water-damage work to carpet cleaners and fire restorers across North America.
Credit
Claude Blackburn, Dri-Eaz
1985
Dehumidifier maker dries buildings
Munters, the Swedish dehumidifier maker founded by Carl Munters in 1955, launched Moisture Control Services (MCS) in 1985 to dry water-damaged buildings, and by the 1990s it worked in more than 20 countries. By the account of Polygon, its successor, MCS operated in "a high-volume, low-value business environment that relied on large numbers of people to deliver the service" and "never reached the profitability expectations of the parent company". Munters sold it in 2010, and it became Polygon.
LessonOwning the drying machines did not make drying buildings pay, because the cost is in the people on site.
Credit
Munters; Polygon
1994
A standard for water damage
The Institute of Inspection, Cleaning and Restoration Certification (IICRC) published the first edition of S500, its standard for professional water damage restoration, in 1994, with new editions in 1999, 2006, 2015 and 2021; the 2021 fifth edition is an American National Standard. It sorts water by contamination: Category 3 is "grossly contaminated" water such as sewage, seawater and rising river water. When the water is Category 1 the restorer can dry without containment, while Category 2 and 3 losses need contamination controls and cleanup before drying. The standard leaves finding and fixing the source of the water to the owner. A new consensus body is now revising the 2021 edition.
Credit
IICRC S500 Consensus Body
2013
Drying paid by formula
On 14 May 2013 the US National Flood Insurance Program (NFIP), run by FEMA, told the insurers that handle its claims how much structural drying to pay for: one, two or three days, depending on how long the building stayed wet; low grain refrigerant dehumidifier capacity in pints of the industry's AHAM rating equal to the room volume in cubic feet divided by 50; one air mover per 16 linear feet of exposed wall on day one and half as many on day two; and no drying of carpet and drywall that flood water had ruined and that should be removed. A drying log, the daily record of indoor and outdoor temperature and humidity, moisture readings and equipment, must back the invoice, and charges beyond these limits go to an independent review.
LessonOnce a payer fixed equipment counts by formula, the drying log became the evidence that settled the bill.
Credit
FEMA, National Flood Insurance Program
2026
Wind-driven rain clarified
The 2021 S500 lists "wind-driven rain from hurricanes, tropical storms, or other weather-related events" among examples of water that "can" be Category 3. On 10 February 2026 the S500 consensus body said that roof leaks, wind-driven rain and other storm water "are not automatically considered Category 3 Water": "can" marks a possibility, not the standard of care, and the category is set by inspecting the loss.
LessonAn example in a standard had come to be read as a rule, with costly containment and tear-out following from it.
Credit
ANSI/IICRC S500 Consensus Body
Watch for
Remote monitoring cuts drying days
Dantherm Group says sensors that send humidity and moisture readings from the drying area to the office, and let staff switch equipment off remotely, cut costs by "up to 30%". In its worked example for 10,000 claims a year at EU average prices, drying time falls from 24 to 21 days per claim and driving per claim from 200 km to 80 km. Remote monitoring is not new (Caption Data released its HygroNet wireless monitor in 2012), but these savings are a modeled scenario.
Achieved whenan insurer or an outside party publishes measured drying days and site visits for matched claims with and without monitoring.
Claimed by
Dantherm Group, August 2026
LGR claims at low humidity
A low grain refrigerant (LGR) dehumidifier is a refrigerant unit built to keep pulling water when the air is already dry, near the end of a job. Legend Brands, maker of Dri-Eaz units, says many units sold as LGR are "not often checked thoroughly" at dry test conditions such as 80 °F and 20% relative humidity, and that its engineers test each model at 15 to 20 conditions for up to 1,500 hours, giving "superior performance versus competitive models across the full drying range".
Achieved whenan independent laboratory publishes water removed per day for several makers' units at the same dry conditions.
Claimed by
Legend Brands, June 2025
Open
01
Open drying logs
A public dataset of drying records from closed water-damage jobs, with addresses removed: daily temperature and relative humidity inside and outside the drying area, moisture readings for each material, equipment counts and run hours, the water's category, and the day each material reached its dry goal. Add a baseline model that predicts the days to dry from the first day's readings.
The briefCredit · unclaimed02
Air movers in a tent
A repeatable garage test of how drying time changes with the number of air movers. Build identical wall sections from new studs and drywall, with new carpet and pad below, soak each with a weighed amount of clean tap water, and dry them inside a plastic-sheet drying chamber with one LGR dehumidifier and zero to four air movers. Weigh the sections continuously and log temperature, humidity and power until each returns to its dry weight, then discard the materials.
The briefCredit · unclaimed03
Dehumidifiers at late-job conditions
An independent chamber test of restoration dehumidifiers, LGR and desiccant, at the dry conditions found late in a job (for example 80 °F at 20% relative humidity and 70 °F at 30%) as well as the 80 °F, 60% point used for ratings, publishing water removed per day and per kilowatt-hour for each model.
The briefCredit · unclaimed
Open 01 · the brief
Open drying logs
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public dataset of drying records from closed water-damage jobs, with addresses removed: daily temperature and relative humidity inside and outside the drying area, moisture readings for each material, equipment counts and run hours, the water's category, and the day each material reached its dry goal. Add a baseline model that predicts the days to dry from the first day's readings.
Why it is still open
Drying records stay inside contractors' and vendors' systems. Fraunhofer IBP in Stuttgart has run many chamber tests of how walls, floors and ceilings dry after artificial water damage, but "on behalf of industrial customers". Dantherm's 24-to-21-day figure comes from a modeled scenario, not a dataset. No public collection of job drying logs was found.
Built with what exists
Exports from the job-documentation software firms already use; an AI model to read scanned paper drying logs, with a person checking a sample; Python with pandas and scikit-learn; Hugging Face Datasets for release under an open licence.
First step
Ask two restoration firms for 50 closed Category 1 jobs each, exported with names and addresses removed.
Done looks like
At least 1,000 jobs from at least five firms in at least two countries, published under an open licence, and a baseline model whose median error in days to dry on held-out jobs is reported beside a simple rule of thumb.
Open 02 · the brief
Air movers in a tent
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A repeatable garage test of how drying time changes with the number of air movers. Build identical wall sections from new studs and drywall, with new carpet and pad below, soak each with a weighed amount of clean tap water, and dry them inside a plastic-sheet drying chamber with one LGR dehumidifier and zero to four air movers. Weigh the sections continuously and log temperature, humidity and power until each returns to its dry weight, then discard the materials.
Why it is still open
Payers already count air movers by rule: the National Flood Insurance Program's 2013 claims guidance pays for one air mover per 16 linear feet of wet wall on the first day and half as many on the second, but cites no test behind those numbers. The published tests found are single runs or private. A 2017 pilot reported in Restoration & Remediation magazine dried one flooded room during a training class in Ohio, and Fraunhofer IBP's chamber tests were made for clients.
Built with what exists
New studs, gypsum board, carpet and pad; load cells with an HX711 amplifier on an Arduino or Raspberry Pi; Sensirion SHT4x temperature and humidity sensors; a pin moisture meter; a plug-in energy meter; a rented LGR dehumidifier and axial air movers; Python.
First step
Build two identical wall sections, soak one, and log its weight and humidity through one full drying run.
Done looks like
Five repeats at each of five air-mover counts (25 runs), with the hours to return within 1% of dry weight and the kilowatt-hours per kilogram of water removed for each, the data and build drawings published, and a second group repeating one setting within 15% of the first group's drying time.
Open 03 · the brief
Dehumidifiers at late-job conditions
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
An independent chamber test of restoration dehumidifiers, LGR and desiccant, at the dry conditions found late in a job (for example 80 °F at 20% relative humidity and 70 °F at 30%) as well as the 80 °F, 60% point used for ratings, publishing water removed per day and per kilowatt-hour for each model.
Why it is still open
A maker, Legend Brands, wrote in June 2025 that LGR claims are "not often checked thoroughly" at such conditions. For household dehumidifiers the US Department of Energy moved ratings to cooler, "more realistic" test conditions from 2019, which lowered rated capacities; no comparable independent test of restoration units was found.
Built with what exists
A psychrometric test room at a university heating and cooling lab, or a sealed insulated room with a heater and an ultrasonic humidifier as the moisture load; calibrated humidity probes; a scale for the condensate; an energy meter; units rented from equipment dealers.
First step
Run one rented LGR unit for 24 hours at 80 °F and 60%, then at 80 °F and 20%, in a sealed room, weighing the water it collects.
Done looks like
At least eight models from at least four makers, each run three times for 24 hours at four conditions, with liters per day and liters per kilowatt-hour published beside each maker's rating and the method written so another lab can repeat it.