BRENNEN

Industries / Consumer goods / Consumer appliances

Energy efficiency

Making appliances use less electricity and water, and the rules, labels and tests that measure how much they use.

7

Milestones achieved, from 1977 to 2021.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1977

    California sets the first standards

    California's 1974 Warren-Alquist Act created the California Energy Commission (CEC) and, in the CEC's words, mandated "the first-ever energy efficiency standards for appliances and buildings". The CEC first developed its appliance standards in 1977. The CEC credits the argument that a better refrigerator alone could save as much energy as a nuclear plant then proposed for the state. A national law, the National Appliance Energy Conservation Act, followed in 1987, and the first federal refrigerator standard took effect in 1990. The Appliance Standards Awareness Project, an advocacy group, says new US refrigerators use about one quarter of the energy of 1972 models while holding almost 30% more.

    energy.ca.govenergy.ca.govappliance-standards.org

    Credit

    the California Energy Commission; the US Congress

  2. 1995

    Europe labels its fridges

    A Council directive of 22 September 1992 set up one European energy label for household appliances, among them refrigerators, freezers, washing machines and dryers, because separate compulsory national labels would have created barriers to trade between member states. A Commission directive of January 1994 fixed the label for refrigerators and freezers, and member states had to apply it from 1 January 1995.

    eur-lex.europa.eueur-lex.europa.eu

    Credit

    the Council of the European Communities and the European Commission

  3. 2004

    Japan's best becomes the rule

    Japan's Top Runner program, introduced in 1998, takes the most efficient model in a product category as the target that each maker's sales-weighted average must reach by a target year, and names makers that fall short. A government advisory subcommittee reported in 2006 that refrigerators sold in the target year, fiscal 2004, used 290.3 kWh a year on average, 55.2% less than the 647.3 kWh before the program; the expected cut had been 30.5%.

    LessonThe same report found the 1999 test method "far from actual status of use", because of how thermostats were set and heaters ran, and replaced it with a new Japanese standard in 2006.

    eccj.or.jpbigee.net

    Credit

    Japan's Ministry of Economy, Trade and Industry and its Agency for Natural Resources and Energy

  4. 2005

    China grades its appliances

    In March 2005 China began requiring an energy label that ranks models of the same type in five grades, from 1, the most efficient, to 5, the legal minimum. It started on refrigerators and air conditioners and covered 15 products by the end of 2009. Ratings rest on energy use reported by the makers themselves. China had run a voluntary endorsement label since 1998.

    LessonBerkeley Lab researchers left the label's effect out of their 2011 estimate of China's appliance savings for lack of market data.

    osti.gov

    Credit

    China's national government

  5. 2008

    The ice maker loophole

    The US test for refrigerators required the ice maker to be on but not making ice; LG read that as switching it off. Consumer Reports tested an LG model in 2008 and measured about 547 kWh a year with the ice maker idle and about 1,110 kWh with it working. On 14 November 2008 LG agreed with the US Department of Energy (DOE) to pay buyers of about 377,500 LG-made refrigerator-freezers, including Kenmore models, for energy use above their labels. By January 2010 DOE had found that LG was using the ENERGY STAR label on about 40,000 products that did not qualify, and a federal court refused LG's request to stop DOE (Inside Climate News).

    LessonA test that does not match how people use an appliance can be read in a way that halves the energy a label shows.

    insideclimatenews.orgenergy.gov

    Credit

    a failure; found by Consumer Reports' testing and acted on by DOE

  6. 2010

    A one-watt standby ceiling

    A European Commission regulation of December 2008 capped the power that household and office equipment may draw when switched off or waiting in standby. From one year after it took effect, the cap was 1 W (2 W with a status display); from four years after, 0.5 W (1 W with a display). The Commission put the EU's standby and off-mode use at 47 TWh in 2005 and expected the rule to save 35 TWh in 2020. A 2013 regulation added limits for networked standby, when a connected product waits for a signal from the network. A 2023 regulation replaced both from 9 May 2025 and caps networked standby at 2 W for most connected equipment, including ovens, microwaves and tumble dryers; washing machines and dishwashers have had their own 2 W cap since 1 March 2021.

    eur-lex.europa.eueur-lex.europa.eueur-lex.europa.eu

    Credit

    the European Commission

  7. 2021

    Labels reset, tests policed

    On 1 March 2021 the EU replaced the refrigerator label's A+++ to D scale with a new A to G scale, leaving the top class nearly empty, and added a QR code linking each label to the model's entry in a public EU product database (EPREL). Which? reports that fridges once rated A+++ are now rated D, and in October 2026 it listed five A-rated fridge freezers it had tested. In the same year the EU-funded ANTICSS project, led by Germany's Öko-Institut from April 2018 to September 2021, finished lab tests of 24 product models and found 6 that behaved differently under test, mostly through a preset or manual change that affected performance or energy use during testing.

    LessonLater EU rules ban products that detect a test and change how they run during it, and forbid software updates that worsen declared results.

    eur-lex.europa.euwhich.co.ukcordis.europa.eueur-lex.europa.eu

    Credit

    the European Commission; the Öko-Institut and the ANTICSS partners

Watch for

  1. LG's beyond-A claims

    LG says its flagship washing machine beats the A-grade requirement by up to 70%, its bottom-freezer refrigerators by up to 35%, and its Hybrid Air Dry dishwashers by up to 30%, and that it is moving this efficiency from flagship into mainstream models. The report names no models, does not say which label scheme is meant, and does not say who measured the figures.

    Achieved whenthe named models' entries in the EU product database carry these values and a market surveillance authority or independent lab measures them within the allowed tolerance.

    itbrief.co.uk

    Claimed by

    LG Electronics, August 2026, as reported by IT Brief UK

  2. ENERGY STAR changes hands

    The US Environmental Protection Agency (EPA) signed an agreement in March 2026 for the Department of Energy to take over the ENERGY STAR label, with the program leaving EPA entirely from June 2026. Congress had funded it at US$33 million for fiscal 2026 and required the money to be spent, while the administration's fiscal 2027 budget again proposes eliminating the EPA office that used to run it.

    Achieved whenDOE publishes an updated ENERGY STAR specification for a home appliance and the list of newly certified appliance models keeps growing under DOE.

    facilitiesdive.com

    Claimed by

    EPA and DOE, March 2026, as reported by Facilities Dive in April 2026

Open

  1. 01

    Fridges metered at home

    An open dataset of 100 refrigerators and fridge-freezers, all rated on the EU's A to G label, each metered in a home for 12 months: electricity every minute, kitchen temperature and door openings. Match each fridge to its official record through the QR code on its label, and publish each model's measured use against its labeled annual use, and how that gap changes with kitchen temperature and age.

    The brief
    Credit · unclaimed
  2. 02

    Connected appliances on standby

    A public table, naming each model, of networked standby power, the power an appliance draws while waiting for a command from its app, for 30 Wi-Fi washers, dryers, dishwashers, ovens and microwaves sold in the EU. Measure each with a power analyzer under the EU method, record how long each takes to drop into that mode, and compare both with the 2 W limit and the maker's declared value.

    The brief
    Credit · unclaimed

Open 01 · the brief

Fridges metered at home

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open dataset of 100 refrigerators and fridge-freezers, all rated on the EU's A to G label, each metered in a home for 12 months: electricity every minute, kitchen temperature and door openings. Match each fridge to its official record through the QR code on its label, and publish each model's measured use against its labeled annual use, and how that gap changes with kitchen temperature and age.

Why it is still open

Field comparisons exist but are old, small or closed. Meier and Jansky at Berkeley Lab compared 209 US refrigerators with their labels around 1991 and found the label overstated field use for a typical unit by about 15%. Biglia and others (2020) compared lab and home use for 124 UK cold appliances and found 61% used more at home. Hüppe and others (2021) modeled German use from a survey of 706 households and found efficiency losses of at least 1% a year. The open REFIT dataset (Murray and others, 2017) logged nine appliances in each of 20 UK homes every 8 seconds for two years, without matching them to their labels. Which? measures energy in its own lab and keeps full results for members. None of these publishes home data, model by model, for fridges on the current label.

eta.lbl.govdoi.orgmb.uni-paderborn.deebi.ac.uk

Built with what exists

Smart plugs that measure energy, such as the Shelly Plug S Gen3, each checked against a calibrated meter before use; Zigbee door and temperature sensors; Home Assistant to log the data; the public EU product database (EPREL) for each model's declared values.

  1. First step

    Meter two fridges for a month, scan their labels' QR codes into a sheet, and compare the readings with the declared values.

  2. Done looks like

    100 fridges with at least 12 months of data each, published under an open license with each model's ratio of measured to labeled annual energy and a 95% confidence interval for the median ratio of each label class.

Open 02 · the brief

Connected appliances on standby

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public table, naming each model, of networked standby power, the power an appliance draws while waiting for a command from its app, for 30 Wi-Fi washers, dryers, dishwashers, ovens and microwaves sold in the EU. Measure each with a power analyzer under the EU method, record how long each takes to drop into that mode, and compare both with the 2 W limit and the maker's declared value.

Why it is still open

Market surveillance authorities test connected products but publish results without model names. In the EU's EEPLIANT2 joint action (2017 to 2020), 59 connected products, among them coffee machines and robot vacuum cleaners, were tested, and 80% had some compliance problem, 29% with standby power. EEPLIANT4's December 2025 newsletter says early findings from its review of networked products under the 2023 rule show "whole industry segments with very low compliance rates", with many suppliers failing to publish the information the rule requires. The IEA's 4E program measured 236 smart lamps, not appliances. No public, model-by-model measurements of connected major appliances against the limits were found.

energimyndigheten.seenergimyndigheten.seeur-lex.europa.euiea-4e.org

Built with what exists

A plug-in power analyzer suited to IEC 62301, the standard for measuring standby power, such as a Yokogawa WT310E; a home Wi-Fi router; each maker's app to send the wake-up command; Home Assistant or a spreadsheet to log readings.

  1. First step

    Borrow a power analyzer, measure two connected appliances already in a home, and write the procedure up so others can repeat it.

  2. Done looks like

    30 models measured three times each, published with photos of the rating plates and the declared values, and any model above 2 W reported to the national market surveillance authority.