Clearance testing is the independent check, after removal or cleanup, that a space is clean enough for people to use again: an inspector looks for leftover dust and debris, then tests the air or wipes surfaces and sends the samples to a laboratory.

7

Milestones achieved, from 1987 to 2026.

1

To watch for: announced, not yet confirmed outside.

3

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1987

    TEM clearance for schools

    EPA's AHERA rule of 30 October 1987 set when a school asbestos job counts as finished. Five air samples inside the work area, analyzed by TEM, must not differ from five taken outside at the same time, judged by a statistical Z-test; or, with large enough air volumes, their average must stay below the filter background of 70 structures per square millimeter. Phase contrast microscopy, a cheaper light-microscope fiber count, is allowed only for jobs up to 160 square feet or 260 linear feet.

    law.cornell.edunist.gov

    Credit

    US EPA; NIST NVLAP

  2. 1996

    French air limit set

    France's 1996 asbestos decree required that, after removal work and before rooms are handed back, the dust in the air be measured once the enclosure comes down, by an approved body, and be no more than 5 fibers per liter. A 2001 amendment added a visual check of the treated surfaces by a qualified technician.

    aida.ineris.fr

    Credit

    French government (Decree 96-97)

  3. 2001

    First US lead dust limits

    EPA's 2001 rule set the first federal clearance levels for lead in dust after abatement: 40 micrograms per square foot (µg/ft²) on floors, 250 on window sills and 400 on window troughs, measured by wiping surfaces and sending the wipes to a laboratory. Surfaces that fail are cleaned again and retested.

    LessonThe levels apply only when someone chooses to abate; EPA's dust standards do not make owners test.

    federalregister.govepa.gov

    Credit

    US EPA

  4. 2005

    UK four-stage clearance

    HSE first published its analysts' guide, HSG248, in 2005. Under the current edition, after licensed asbestos removal indoors an analyst must pass four stages in order: a check that the job is complete, a thorough visual inspection inside the enclosure, air sampling while surfaces are brushed (fibers must be below 0.010 per milliliter), and a final look once the enclosure is down. Only then does the analyst sign a certificate for reoccupation. HSE counted more than 30,000 such clearances a year in 2019–2020.

    LessonHSE warns that passing the air test does not mean the air is free of asbestos; it shows the site was clean before the enclosure came down.

    hse.gov.uk

    Credit

    UK Health and Safety Executive

  5. 2021

    Court sends levels back

    On 14 May 2021 the US Court of Appeals for the Ninth Circuit held that EPA's 2019 dust-lead hazard levels, 10 µg/ft² on floors and 100 on sills, were not low enough to protect health because EPA had weighed factors other than health. It told EPA to set hazard levels on health alone, while clearance levels may still weigh what labs can measure. EPA had lowered clearance levels to the same 10 and 100 from 8 March 2021; HUD had required 10 on floors and 100 on sills and troughs of its lead grant programs since February 2017.

    LessonA health standard and a cleanup pass mark answer different questions, so they can carry different numbers.

    federalregister.govfederalregister.gov

    Credit

    US Court of Appeals for the Ninth Circuit (A Community Voice v. EPA); EPA; HUD

  6. 2021

    Analysts' site work inspected

    HSE inspected asbestos analysts at work in 2014–15 and reported in 2018. Inspectors found samples taken in only some rooms of multi-room enclosures, too little time spent counting slides, brushes and mirrors not used, and unshaven analysts whose respirators could not seal. The 2021 second edition of HSG248 strongly recommends that the building owner or occupier, not the removal contractor, hire the clearance analyst.

    LessonA pass or fail is only as good as the analyst on the day, so the guide calls for close supervision of analysts' site work.

    hse.gov.uk

    Credit

    UK Health and Safety Executive

  7. 2026

    Lower lead limits take effect

    EPA's rule of 12 November 2024 split the two numbers. In a risk assessment, any lead that a recognized lab can report in floor or sill dust now counts as reportable, while an abatement passes clearance only below 5 µg/ft² on floors, 40 on sills and 100 on troughs, from 12 January 2026. Recognized labs must be able to quantify 4 µg/ft² on floors under EPA's lab standard LQSR 4.0, mandatory after 22 December 2025.

    LessonThe exact wording matters as much as the numbers: the version in force from 13 January 2025 had dropped three paragraphs on post-abatement steps by mistake until EPA restored them on 9 July 2025.

    epa.govfederalregister.govfederalregister.govfederalregister.gov

    Credit

    US EPA

Watch for

  1. Labs at the floor limit

    EPA expects labs using ICP-AES instruments (which measure metals in a plasma) to "comfortably" quantify lead at 4 µg/ft² on floor wipes, and says labs using the more common flame atomic absorption (FAAS) may need newer instruments or changed methods. Its February 2026 pamphlet supplement now tells families that any lead dust a recognized lab can report is a hazard, so where that line falls depends on each lab.

    Achieved whenan outside party, such as a proficiency-testing round or a state audit, publishes how many recognized labs report floor wipes at or below 4 µg/ft².

    federalregister.govepa.gov

    Claimed by

    EPA, November 2024, with lab deadlines of 22 December 2025 and 12 January 2026

Open

  1. 01

    Lead clearance report checker

    A tool that reads a finished lead clearance report (visual assessment, sample locations, lab results) and checks each wipe against the clearance level in force on its date (10, 100 and 400 µg/ft² before 12 January 2026; 5, 40 and 100 after), confirms the lab is EPA-recognized, and flags any field missing from HUD's review worksheet.

    The brief
    Credit · unclaimed
  2. 02

    Reoccupation certificate checker

    A tool that reads UK certificates for reoccupation and checks each one against HSG248: all four stages recorded in order, the photos listed in Table 6.1 present, the air result below 0.010 fibers per milliliter with enough air sampled and fields counted, and an analyst independent of the removal contractor.

    The brief
    Credit · unclaimed
  3. 03

    Lab reporting limit census

    A public table of every EPA-recognized lead lab's reporting limit for dust wipes, in micrograms per wipe and per square foot, with its method (FAAS, ICP-AES or ICP-MS). Use it to show how the same wipe can be a "reportable" hazard at one lab and below the reporting limit at another.

    The brief
    Credit · unclaimed

Open 01 · the brief

Lead clearance report checker

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A tool that reads a finished lead clearance report (visual assessment, sample locations, lab results) and checks each wipe against the clearance level in force on its date (10, 100 and 400 µg/ft² before 12 January 2026; 5, 40 and 100 after), confirms the lab is EPA-recognized, and flags any field missing from HUD's review worksheet.

Why it is still open

HUD's guidelines give reviewers a paper Clearance Report Review Worksheet (Form 15.3) with a completed example, and states publish report templates, but searches found no software that checks finished reports against the 2026 levels.

hud.govepa.gov

Built with what exists

An AI model that reads PDFs and cites the rule behind each finding (see the Note "Findings that cite notes"), plain Python rules for the number checks, and EPA's public list of recognized labs.

  1. First step

    Build 20 test reports from HUD's completed example in Chapter 15, each with one deliberate fault, and record the right answer for each.

  2. Done looks like

    On a public test set of 100 reports, made from HUD's worked examples with seeded faults, the tool catches at least 95% of seeded faults and wrongly flags no more than 5% of clean reports.

Open 02 · the brief

Reoccupation certificate checker

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A tool that reads UK certificates for reoccupation and checks each one against HSG248: all four stages recorded in order, the photos listed in Table 6.1 present, the air result below 0.010 fibers per milliliter with enough air sampled and fields counted, and an analyst independent of the removal contractor.

Why it is still open

HSE found its 2014–15 problems by sending inspectors to sites. Its scientists then watched clearances at eight licensed removals from 2016 to 2019, and their report, RR1218, published early in 2025, found that certificates were issued at every site but "were not always clear, unambiguous and accurate". HSG248 relies on each organization's own desk reviews of completed certificates, and the audit forms found online are paper checklists. Searches found no published automated check.

hse.gov.ukhse.gov.ukatac.org.uk

Built with what exists

An AI model that reads scanned PDFs and answers fixed yes-or-no checklist questions (see the Note "A thousand questions, one pass"), Python, and a checklist written from HSG248.

  1. First step

    Write the checklist from HSG248's Appendix 5 and Table 6.1, then ask one accredited analyst firm for 20 redacted certificates.

  2. Done looks like

    On 200 redacted certificates, the tool agrees with an experienced reviewer on at least 90% of checklist items, and the published checklist and scores let others repeat the test.

Open 03 · the brief

Lab reporting limit census

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public table of every EPA-recognized lead lab's reporting limit for dust wipes, in micrograms per wipe and per square foot, with its method (FAAS, ICP-AES or ICP-MS). Use it to show how the same wipe can be a "reportable" hazard at one lab and below the reporting limit at another.

Why it is still open

Because EPA now defines a dust-lead hazard as any level a recognized lab can report, the line moves from lab to lab. EPA's own picture comes from teleconferences with 18 recognized labs during the rulemaking. An independent directory on GitHub (November 2026) already lists the 104 labs in EPA's October 2026 list, with whether each tests paint, dust or soil, but not their reporting limits; no public lab-by-lab table of limits was found.

federalregister.govepa.govgithub.com

Built with what exists

EPA's list of recognized labs, labs' published method sheets and price lists, a short email survey, and a spreadsheet.

  1. First step

    Download EPA's current list of recognized labs and record the published dust-wipe reporting limits of the first 20.

  2. Done looks like

    Reporting limits, each with its source, for at least 90% of the labs on EPA's list, published openly with the date collected.