Indoor air

Indoor air monitoring measures gases, particles and fresh-air supply inside homes, schools, offices and public buildings.

7

Milestones achieved, from 1913 to 2024.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1913

    Schools' air put to test

    Many US states then required at least 15 liters per second of fresh air per person, a rate Billings and his colleagues had proposed to clear occupants' "organic exhalations". New York State formed a Ventilation Commission in 1913 to study the needs of schools and other public buildings, and its report found the 15 L/s rule not justified and 5 to 7.5 L/s per person adequate for classrooms.

    pmc.ncbi.nlm.nih.gov

    Credit

    New York State Commission on Ventilation; account by Persily (2015)

  2. 1984

    The house that tripped alarms

    In December 1984 Stanley Watras, an engineer at the Limerick nuclear plant in Pennsylvania, kept setting off the plant's radiation monitors on his way in to work. Air in his home held radon decay products at 13.5 working levels (a unit set for uranium miners), 675 times the guideline the state soon adopted, and the family was told to leave at once. Pennsylvania's environment department then tested more than 22,000 homes in 18 months and found 50% to 60% above its 0.02 working-level guideline. Repairs paid for by the utility, Philadelphia Electric Company, cost more than $32,000 and cut the Watras home to 0.009 working levels.

    LessonEPA's deputy administrator noted that radon in "the house right next door" was normal, so only a test in each home can tell.

    epaalumni.orgcontent.time.com

    Credit

    Stanley Watras; Philadelphia Electric Company; Pennsylvania Department of Environmental Resources; US EPA

  3. 1989

    Fresh air rates restored

    ASHRAE, the engineers' society for heating, ventilation and air conditioning, published its first ventilation standard, Standard 62, in 1973, with a minimum of 7.5 L/s of outdoor air per person in offices. The 1981 edition cut non-smoking offices to 2.5 L/s per person, partly to save energy; the 1989 edition raised offices to 10 L/s and classrooms to 8 L/s per person. The 1989 edition also set an indoor carbon dioxide (CO2) limit of 1,800 mg/m³, about 1,000 parts per million (ppm), which became a de facto standard "without a sound understanding of its basis", in Persily's words.

    LessonIndoor CO2 near 1,000 ppm signals too little fresh air for the number of people in a room; it is not a health limit for CO2 itself.

    pmc.ncbi.nlm.nih.gov

    Credit

    ASHRAE Standard 62 committee; account by Persily (2015)

  4. 2007

    Trailers tested too late

    After hurricanes Katrina and Rita, the US Federal Emergency Management Agency (FEMA) housed families in trailers, and in 2006 local doctors reported more breathing complaints among residents. Formaldehyde levels in the occupied trailers were unknown until the Centers for Disease Control and Prevention (CDC) tested the air in a random sample of 519 trailers in Louisiana and Mississippi, drawn in November 2007. Levels ranged from 3 to 590 parts per billion (ppb), with a geometric mean (a typical value for skewed data) of 77 ppb, and every trailer type had some readings of 100 ppb or more.

    LessonThe air was measured only after people had lived in the trailers and reported symptoms.

    ebi.ac.uk

    Credit

    M. W. Murphy and colleagues, CDC National Center for Environmental Health

  5. 2013

    Europe caps home radon

    The World Health Organization (WHO) published a handbook on indoor radon in 2009. It recommends a national reference level of 100 Bq/m³ (becquerels per cubic meter, radioactive decays per second in each cubic meter of air), and no more than 300 Bq/m³ where that cannot be met, and estimates that radon causes 3% to 14% of a country's lung cancers. On 5 December 2013 the EU's Council Directive 2013/59/Euratom required every member state to set a reference level for indoor radon no higher than 300 Bq/m³ as a yearly average, to adopt a national radon action plan, and to promote finding and fixing homes above the level.

    who.intwho.intpublications.europa.eu

    Credit

    WHO; Council of the European Union

  6. 2021

    CO2 monitors in classrooms

    In August 2021 the Department for Education said it would send about 300,000 CO2 monitors, backed by £25 million, to all state-funded schools and colleges from September, so staff could spot poor ventilation and limit the spread of Covid-19. SAMHE, a research project funded by UK Research and Innovation, later analyzed 38,000 school days of data from 346 UK schools and found that many classrooms meeting school guidance had ventilation rates far below the minimum set for most workplaces.

    LessonMonitors alone did not fix ventilation; SAMHE noted in November 2024 that schools had no requirement to monitor air routinely and no means of enforcing the guidance.

    gov.uksamhe.org.uk

    Credit

    Department for Education; SAMHE

  7. 2024

    Gas stoves measured at home

    Researchers at Stanford University combined emission and concentration measurements from more than 100 homes with a room-by-room indoor air model to estimate US exposure to nitrogen dioxide from gas and propane stoves. They found the stoves add 4.0 ppb to long-term exposure on average, 75% of the WHO guideline, and that short-term levels from typical use often exceed WHO and EPA benchmarks; they estimate about 50,000 current cases of childhood asthma from the long-term exposure.

    ebi.ac.uk

    Credit

    Yannai Kashtan, Robert Jackson and colleagues, Stanford University (Science Advances, May 2024)

Watch for

  1. Air labels for public places

    Belgium's federal law on indoor air in places open to the public sets reference levels for CO2 and makes a meter that measures at least CO2 mandatory, but sets no binding minimum performance. According to Peter Wouters and Arnold Janssens, the government intends to add certification and labeling for all public places, taking in the effect of air cleaners, so that the public can see how each space performs.

    Achieved whena labeling scheme is in force and an outside count or audit reports how many places hold labels and what their meters show.

    aivc.org

    Claimed by

    the Belgian federal government, as described at the BUILDAIR Symposium, May 2025

  2. Air monitors in EU buildings

    The EU's 2024 recast buildings directive requires member states to make new non-residential zero-emission buildings carry devices that monitor and regulate indoor air quality, and to require them in existing non-residential buildings at major renovation where technically and economically feasible. National laws were due by 29 May 2026. New buildings must be zero-emission from 1 January 2028 if public bodies own them and from 1 January 2030 for all.

    Achieved whenthe European Commission confirms that member states have put Article 13(5) into national law and a survey finds the devices installed and recording in new non-residential buildings.

    publications.europa.eu

    Claimed by

    the European Parliament and Council, Directive (EU) 2024/1275, with national laws due May 2026

Open

  1. 01

    Recheck the school CO2 monitors

    A test of the CO2 monitors the Department for Education sent to schools in 2021, now about five years in service: borrow units from schools, check each against a reference CO2 analyzer at several set levels, and publish how far each has drifted.

    The brief
    Credit · unclaimed
  2. 02

    Check home formaldehyde readings

    A public test of consumer air monitors that display formaldehyde, run in a test chamber and in homes beside air samples taken on cartridges that trap formaldehyde and are then analyzed by an accredited lab.

    The brief
    Credit · unclaimed

Open 01 · the brief

Recheck the school CO2 monitors

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A test of the CO2 monitors the Department for Education sent to schools in 2021, now about five years in service: borrow units from schools, check each against a reference CO2 analyzer at several set levels, and publish how far each has drifted.

Why it is still open

About 300,000 monitors went out from September 2021. Published tests of classroom monitors used units that were new or in short trials. Krishnan and colleagues (REHVA Journal, 2022) tested 16 monitors in a climate chamber at Eindhoven University of Technology against an SBA-5 analyzer and found average errors of 32.5 to 415.4 ppm, worse than most makers' stated accuracy. Honan and colleagues (Sensors, February 2026) co-located 23 sensors under Irish school conditions in 2025 without a laboratory reference and did not report long-term drift. A search found no test of the 2021 school units after years of use.

gov.ukrehva.eupure.ul.ie

Built with what exists

A reference CO2 analyzer such as the PP Systems SBA-5 used in the Dutch test; certified CO2 gas at about 400, 1,000 and 2,000 ppm; a sealed test box; Python for the analysis.

  1. First step

    Find which monitor models were supplied, then ask five schools to lend two units each for a pilot test in one sealed box.

  2. Done looks like

    At least 100 of the 2021 monitors from at least 20 schools tested at three CO2 levels, with the share reading within the maker's stated accuracy published along with the raw data, and 10 units retested by a second lab with results within the stated uncertainty.

Open 02 · the brief

Check home formaldehyde readings

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public test of consumer air monitors that display formaldehyde, run in a test chamber and in homes beside air samples taken on cartridges that trap formaldehyde and are then analyzed by an accredited lab.

Why it is still open

South Coast AQMD's AQ-SPEC table, the main public test bench for sensors, has no rows for formaldehyde or CO2 and lists only two sensors for total volatile organic compounds (TVOC), both tested in the lab. RESET Air's sample accreditation report checks monitors for fine particles, TVOC and CO2 against other monitors used as references, not formaldehyde. Zheyuan Pei, Kerry Kelly and colleagues at the University of Utah tested eight bare SFA30 formaldehyde sensors, a low-cost part made by Sensirion, in the laboratory (Sensors, 2023), and in 2025 tested how the SFA30 and another sensor respond to other gases, but they did not test finished consumer monitors in homes. A search found no independent comparison of consumer formaldehyde readings with lab samples.

aqmd.govreset.builddoi.orgdoi.org

Built with what exists

Two units each of six or more best-selling monitors that show formaldehyde; formaldehyde sampling cartridges, a small pump and an accredited lab; a sealed test chamber; household sources such as new particleboard furniture, plus alcohol and acetone to test false readings; Python.

  1. First step

    Buy two units each of three models and run them for a week beside lab cartridge samples in one room with new particleboard furniture.

  2. Done looks like

    Six or more models tested in 20 homes for a week each with paired lab samples, plus chamber runs with and without interfering vapors, publishing each model's average error and false-alarm rate, with data public.